ORDINARY MEETING AGENDA 20 APRIL 2017
Building Height
The maximum height of the structure must not exceed 46 metres above the
finished ground level and the natural ground surface.
Certification must be submitted to Council from a Licensed Surveyor which
certifies that the monopole structure does not exceed the maximum height
requirement of this Decision Notice.
No lights are permitted to be attached to the telecommunications facility, except
where required for aircraft hazard lighting purposes or similar.
Noise
Equipment, motors, electrical generators, compressors, etc must be suitably
provided with noise reduction measures and located so as to prevent a noise
nuisance beyond the boundary of the site and not exceed the levels specified in
Table 1.
TABLE 1
NOISE LIMITS AT A SENSITIVE RECEPTOR
Noise level at noise sensitive place measured as the adjusted maximum
PERIOD
sound pressure level (LAmax, adj,T)
7am – 6pm Background noise level (LAbg,T) plus 5 dB(A)
6pm – 10pm Background noise level plus 5 dB(A)
10pm – 7am Inaudible
NOISE LIMITS AT A COMMERCIAL PLACE
Noise level at a commercial place measured as the adjusted maximum
PERIOD
sound pressure level (Lamax, adj,T)
7am – 6pm Background noise level (LAbg,T) plus 10 dB(A)
6pm – 10pm Background noise level plus10 dB(A)
10pm – 7am Background noise level plus 8 dB(A)
When requested by Noosa Council, a Noise Impact Assessment Report (NIAR)
showing monitoring and recording of noise levels must be undertaken to
investigate any non-vexatious complaint caused by noise emissions from
operations of the facility. Such monitoring must be undertaken and completed
within a reasonable and practicable timeframe as nominated by Council and be
performed by a suitably qualified and experienced person.
The NIAR is to be submitted to Council detailing the results of such monitoring
and recommendations for any measures to achieve compliance with limits
outlined in Table 1 of this Decision Notice.
Rectification works will be required within a reasonable timeframe as set by
Council where equipment, air conditioning units, motors, electrical generators,
compressors, etc exceed the Noise Limits of Table 1.
Measurement of sound pressure levels (adjusted for tonality and impulse) must
be in accordance with Australian Standard AS1055.1 “Acoustics – Description
and measurement of environmental noise – General procedures”.
For the purpose of measuring and certifying relevant noise conditions and
reporting (eg. equipment, air conditioning units, motors, electrical generators,
compressors, etc), a suitably qualified person is either:
i. a Registered Professional Engineer of Queensland, or
ii. an environmental consultant with a minimum of 3 years current experience
in the field of acoustics.