Council archive · source document
07/2398 - Revised Noise Report and cover letters to referral agencies [As Published] · 132007.2398
RSL Care Proposed RSL Retirement Village, Cooroy - Road and Rail Noise Assessment (Revised) 2 2.1 ASSESSMENT CRITERIA RAIL NOISE The Noosa Shire Council has specified an internal average Lame noise criteria of 50 dB(A) and 55 dB(A) for sleeping and living areas respectively. This criteria has been used for the assessment of rail noise from the Cooroy Rail Corridor located to the west of the development site. 2.2 ROAD TRAFFIC NOISE The Queensland Department of Main Roads through its Road Traffic Noise Management: Code of Practice (2000) specifies noise criteria for new and existing roads. Criteria for proposed residential developments from the Code of Practice specify the requirements for the current and future noise conditions as follows. Criteria for residential development (Temporary or Permanent Occupancy) requires that: Residential (Temporary or Permanent Occupancy) ‘Habitable Floors 60 dB(A) Lio (18 Hour) or less, where existing levels measured at the local government deemed-to—comply dwelling setback distance are greater than 40 dB(A) Loo (8-Hour) between 10 pm and 6 am; or 57 dB(A) Lio (18 hour) or less, where existing levels measured at the local government deemed-to—comply dwelling setback distance are less than or equal to 40 dB(A) Loo (8-hour) between 10 pm and 6 am Where the above criteria cannot be met, intemal maximum design criterion levels specified in table, AS 2107-1987. Note: All extemal levels stated are free-field with the expectation that additional 2.5 dB(A) increase is applied for the facade correction when the building is constructed. This will achieve a level of less than 63 dB(A) and 60 dB(A), respectively, 1 metre from the most exposed facade of a building.’ Specific guidance is also provided by the DMR for outdoor areas at developments: ‘Balconies and formal external open areas 60 dB(A) Lio (18 Hour) or less, where existing levels measured at the local government deemed-to—comply dwelling setback distance are greater than 45 dB(A) Loo (18-Hour); or 57 dB(A) Lio (18 hour) or less, where existing levels measured at the local government deemed-to-comply dwelling setback distance are less than or equal to 45 dB(A) Ls0(18- hour).’ The above criteria has been considered for the purposes of this noise assessment. AIR NOISE ENVIRONMENT PTY LTD INETWORK/PROJECTS/1750/REPORTING/2008 REVISION/1750REPORT04.0DT Page 3
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/2398 - Revised Noise Report and cover letters to referral agencies [As Published]Related documentApplication case desk ↗
About this file
- File size
- 6.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.