07/2398 - Revised Noise Report and cover letters to referral agencies [As Published] · 132007.2398
RSL Care Proposed RSL Retirement Village, Cooroy ~- Road and Rail Noise Assessment (Revised) = STC Requirements for Construction Materials 1 Bed 1 Living/Stu Kitchen ILU No. rem, Bed 4 (sie wont 2 vst. " weit Rear (Biking iting 110 29 31 34 29 33 33 25 111 30 31 34 29 33 33 24 112 28 30 32 29 33 33 24 113 28 31 32 29 33 33 24 114 30 27 29 25 32 32 27 115 29 27 29 26 32 32 27 417 32 26 27 23 30 29 27 TILU building numbers are identified on Figure 7 As identified on Tables 5.9 and 5.10, STC requirements for glass windows can be reduced to 37 or below provided that alternative ILU layouts are provided. Currently, no alternative layouts have been made available to replace the Type 4 double units (Buildings 94, 97, 101, 104, 105, 107, 108, 116 and 118) located near the Cooroy Connection Road. If double units are provided by combining two mirrored atternative single units, window STC values of 37 are likely be achieved for these buildings. However, if alternative designs to those presented in Figure 9 are proposed, an acoustic assessment of these units would be required to determine the required construction materials. Table 5.11 presents potential construction materials suitable for achieving the predicted STC requirements. TABLE 5.11: POTENTIAL CONSTRUCTION MATERIALS stc Component Range Examples of Construction Sheet metal roof with 50 mm Bradford Anticon insulation over 50 battens, ceiling lined with 2 x 10 mm Gyprock Soundchek plasterboard and filled with 130 Comfortseal R3.0W insulation Ceiling / Roof (CSR Redbook). Sheet metal roof with 50 mm Bradford Anticon insulation over 38 battens, ceiling lined with 13 mm and 16 mm Gyprock Fyrchek plasterboard (CSR Redbook). 50 Masonry veneer wall with timber studs, lined internally with 10 Gyprock Plasterboard CD (CSR Redbook). External Walls External cladding material on battens, vapour barrier, 16 mm 36 Gyprock Fyrchek MR plasterboard, timber studs, lined internally with 10 mm Gyprock Fyrchek Plasterboard CD (CSR Redbook). AIR NOISE ENVIRONMENT PTY LTD INETWORK/PROJECTS/1750/REPORTING/2008 REVISION/1750REPORTO4.ODT Page 41
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/2398 - Revised Noise Report and cover letters to referral agencies [As Published]Related documentApplication case desk ↗
About this file
- File size
- 6.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.