Council archive · source document
07/2398 - Revised Noise Report and cover letters to referral agencies [As Published] · 132007.2398
—_—= RSL Care == Proposed RSL Retirement Village, Cooroy - Road and Rail Noise Assessment (Revised) — stTc Component Range Examples of Construction 37 43.52 mm laminated, awning with acoustic seals (Bradnams) 34 10.38 mm laminated, awning with acoustic seals (Bradnams) Windows 29 6.38 mm laminated, sliding with acoustic seals or 6 mm awning (Bradnams) 25 4 mm sliding (Bradnams) 34 13.52 laminated, with acoustic seals (Bradnams) Sliding Doors 30 6.38 laminated, with acoustic seals (Bradnams) 25 4 mm glazing (Bradnams) 30 42-mm solid-core plywood door, soft plastics gasket around sides and top and drop seal at base (AS 3671). Pivot Doors 27 35-mm solid-core plywood door, soft plastics gasket around sides and top and drop seal at base (AS 3671). Before any construction material is chosen for the proposed buildings, STC information should be sought from the suppliers to ensure that the minimum STC’s are achievable. In order to achieve design STC ratings it is essential that the acoustically treated areas be constructed in a manner conducive to maximising sound attenuation. For example, there must be no air gaps around windows or at the eaves, which could act as noise pathways. 5.6.4 Open Space Figure 10a presents predicted ground Lato1enour noise contours across the whole site. Figures 10b to 10f present predicted ground contours for the ILUs adjacent to the Cooroy Connection Road. As identified on these figures, compliance with the DMR criterion for private open space is predicted across the majority of the development. Noise levels at private terrace areas are predicted to exceed the criteria for a number of ILU buildings located adjacent to the Cooroy Connection Road (ILU buildings 94, 97, 104, 107, 108, 115 and 116). However, as indicated on Figures 10b to 10f, a large proportion of compliant area is provided in the shadow region of each ILU building. Hence, compliance with the DMR criterion is predicted provided that private open space is designated in the shadow zone of these ILU buildings. AIR NOISE ENVIRONMENT PTY LTD JNETWORK/PROJECTS/1750/REPORTING/2008 REVISION/1750REPORT04.00T Page 42
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/2398 - Revised Noise Report and cover letters to referral agencies [As Published]Related documentApplication case desk ↗
About this file
- File size
- 6.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.