Council archive · source document
Approved Plans OPW18/0118
Plans and drawings: the text below has words only, no drawings.
LEGEND
T T
EXISTING FEATURES PROPOSED WORKS W W
EXISTING CONTOUR MAJOR PROPOSED KERB TYPE B2 REFER
EXISTING CONTOUR MINOR IPWEAQ STD DRG RS-080
JOINS BELOW
PROPOSED CONCRETE INVERT REFER -
EXISTING KERB AND CHANNEL
EXISTING FENCE IPWEAQ STD DRG RS-080
PROPOSED PAVEMENT, REFER PAVEMENT
NOOSA COUNCIL
T EXISTING TELECOMMUNICATION
EO EXISTING OVERHEAD POWER
SPECIFICATION ON SHEET C004
APPROVED PLAN
W EXISTING WATERMAIN
EXISTING TOP OF BANK OPW18/0118 25 SEP 2018
NOTE: TRANSITION PROPOSED
LINEMARKING AND JOIN AS AMENDED BY CONDITIONS
SMOOTHLY TO EXISTING
INDICATIVE KERB LINE, CONTRACTOR
PAVEMENT MARKINGS LEGEND TO CONFIRM ON SITE TO ENSURE
1.20m MINIMUM CYCLE LANE WIDTH
80mm TWO WAY BARRIER LINE TW
1.208
100mm EDGE LINE EL
80mm EDGE LINE EL*
SETOUT TABLE EL
3.300 2.00 3.300
SINGLE BARRIER LINE BLS
100mm SETOUT_NO EASTING NORTHING LEVEL G O O OM
1m 3m 1m 3m 1m D C H
200mm CONTINUITY LINE CL
01 211.7771 512.7418 8.1890 A P
0.6m 0.9m 0.6m 0.9m 02 229.4394 500.9925 8.8940
150mm YELLOW BUS ZONE BYZ 03 240.6281 491.0018 9.3440 OM
04 249.8186 478.7734 9.7230 EL
S T R E E T
100mm YELLOW NO STOPPING YL 05 238.6299 488.7641 9.2730
0.6m 0.6m 0.6m 0.6m
06 227.4413 498.7548 8.8230
300mm GIVEWAY LINE GW
EO EO
100mm OUTLINE MARKING OM
GREEN LANE LINEMARKING
WITH WHITE BICYCLE SYMBOL
PAVEMENT ARROW 7
RP138403 6 2 1
RP138403 RP180551 RP180551
V E
T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T
W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W
D R I
T
JOINS BELOW
PROPOSED RESIDENTIAL PROPOSED CONCRETE BIN TO BE GOSSI PARK SMOKE RETAIN EXISTING
T DRIVEWAY CROSSOVER IN FOOTPATH IN GREY BIN ENCLOSURE WITH A CONCRETE FOOTPATH
2.000
ACCORDANCE WITH IPWEAQ STD ACCORDANCE WITH CLEAR ANODISED HOOD.
DRG RS-049 & RS-050. RESIDENTS IPWEAQ STD DRG RS-065 SEAT TO BE PROVIDED BY
TO BE NOTIFIED PRIOR TO NOOSA COUNCIL
T
FOR LOCATION AND TYPE OF
A G E
COMMENCEMENT OF WORKS PROPOSED 'RKO' V GRATE ON
TACTILE INDICATORS, J-POLE AND B EXISTING PIT WITH CONCRETE
DISABLED BAYS TO BE IN C004
T
SURROUND, REFER ROKLA FOR
ACCORDANCE WITH TRANSLINK SPECIFICATIONS
STD DRG 5-0014 AND PTIM 2016 4.300 1.500
T RETAIN EXISTING RELOCATE EXISTING
STORMWATER PIT BUS STOP SIGN PROPOSED RESIDENTIAL DRIVEWAY
RETAIN EXISTING RETAIN EXISTING
H E R I T
CONCRETE INDENT IN CROSSOVER IN ACCORDANCE WITH
STORMWATER PIT PEDESTRIAN
ACCORDANCE WITH IPWEAQ STD DRG RS-049 & RS-050.
A REFUGE ISLAND
T
IPWEAQ STD DRG RS-183 RESIDENTS TO BE NOTIFIED PRIOR
4.200
C004
TO COMMENCEMENT OF WORKS
T
02
1.200
3.000
03
T
CL 01 06 05 04
T
CL CL EL CL EL
3.300 2.00 3.300
3.300
EL 21.000 15.000 15.000
OM T
OM CL OM
20.000 BLS
3.000
00
TW
T
.0
OM
R5
OM 35.000 OM
G O O D C H A P
2.111 3.300
C
22.521 15.000 S T R E E T
T
EL C004 EL
3.259
BYZ 1.000
T YL YL
EO EO EO EO EO EO EO EO EO EO EO EO EO EO EO EO EO EO EO EO EO
2.500
EO EO EO EO EO EO EO EO EO
EO EO EO EO EO EO EO
T T T T T T T T T T T T T T T T T T T T T T
2.000
T T T T T T T T T T
T T T T T
T T T T T T T T T T T T T T T T T T T T T T T T GIVEWAY
T SIGN
T T T T T T T T T T T T
(R1-2A) AND LEFT
TURN SIGN (R2-14A)
T
EXISTING TELSTRA PIT
T
J:\2017\17548ID2_Goodchap_Street_Carpark\4.CADD\#ACAD\17548_GOODCHAP.dwg
GWL
T
PROPOSED INTERMEDIATE WEST CAREFULLY POTHOLE TO ENSURE NO
FABRICATED 50mm PLATE
BOUND BUS STOP (NOT PART OF SERVICES IN PIER LOCATIONS. CONTACT
3 2 1 5 COVER WITH CONCRETE
T
ENGINEER WITH RESULTS. 6 NO.
T
0 2 4 6 8 10m RP138403 RP138403 RP138403 WORKS - SHOWN INDICATIVELY) SP196846 INFILL REFER TO DETAILS
Ø300x3500 LONG BORED PIERS 5-N16
1:200 (A1) 1:400 (A3) BARS WITH R10 SPIRAL - 150 PITCH
EL*
T
T
COPYRIGHT © Associated Consultants Client Drawn Verified Project Drawing Title Scale Sheet Size
This drawing is subject to NV BD
copyright in accordance with the
agreement between Tod
N.C. OLIVER Designed Verified
GOODCHAP STREET, NOOSAVILLE GENERAL ARRANGEMENT PLAN AS SHOWN A1
Consulting pty ltd (tc) and tc's
client. This drawing shall only be
NV BD ACCESS IMPROVEMENTS Drawing Number
Approved RPEQ No
used for this specific project.
B. DOWNES 14873 RDP 17548-C003
This drawing shall not be used
Noosa: 07 5449 9600 LOCAL AUTHORITY NSC
B 14.09.18 BUS STOP AMENDED NV Sunshine Coast: 07 5329 3190 Mackay: 07 4840 2337
Signed MCU APPROVAL HORIZ DATUM 0 10 20 30 40 50 60 Sheet Revision
for construction until marked as PO Box 61, Noosaville, QLD 4566
A 03.09.18 RESPONSE TO INFORMATION REQUEST NV ROL APPROVAL VERT DATUM
'issued for construction' in the
revision description. Rev Date Revision Description Drawn
[email protected] www.todconsulting.com
ABN 39 128 805 336
14.09.18 OPW APPROVAL OPW 18/0118 RL DATUM MEASUREMENT BAR - INCREMENTS IN mm
3 of 5 B
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Approved Plans OPW18/0118 .pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.