BUSHFIRE HAZARD ASSESSMENT AND MANAGEMENT PLAN v2 - Coveys Road TINBEERWAH (1)
Plans and drawings
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawnBushfire Hazard Assessment and Management Plan v2 NCES REF: J000545 Lot 2, 4 & 5 on RP172460 & Lot 7 on RP895754 66, 82 & 98 Coveys Rd & 39 Tinbeerwah Rd, Tinbeerwah Table 3 - Risk Assessment - Lot 8 Direction North South/west East North/west Approx. minimum distance to 130m 110m 75m 80m hazardous vegetation VHC’s 8.1 8.1 8.1 8.1 Smoke* Not assessed Not assessed Not assessed Not assessed Ember Acceptable Acceptable Intolerable Intolerable Radiant Heat Acceptable Acceptable Intolerable Intolerable Flame Acceptable Acceptable Tolerable Acceptable Table 4 - Risk Assessment - Lot 9 Direction North South/west East West Approx. minimum distance to 65m >150m 80m 75m hazardous vegetation VHC’s 8.1 N/A 8.1 8.1 Attack Mechanism Smoke* Not assessed Not assessed Not assessed Not assessed Ember Intolerable Acceptable Intolerable Intolerable Radiant Heat Intolerable Acceptable Intolerable Intolerable Flame Acceptable Acceptable Acceptable Acceptable * Risk of smoke impact has not been assessed. Smoke can travel long distances and exhibit a variety of densities and composition. It is therefore not readily practicable to determine the separation distances needed to attain the various risk classes. Furthermore, individuals will react differently to smoke impacts whereas individuals will generally exhibit similar reactions to direct flame and radiant heat. All identified ‘Intolerable risk’ assigned to the new buildings is expected to be reduced to at least a ‘Tolerable risk’ where buildings are constructed in accordance with the National Construction Code 2019 (NCC 2019) AS3959:2018 Construction of Buildings in Bushfire Prone Areas requirements. 5.3 Qualitative Risk Discussion Expansive units of flammable vegetation are located in proximity to the site which have the potential of facilitating either a direct bushfire front onto the site and/or facilitating advance ember attack and radiant heat impact to the site. A discussion of the directional risk acting on the buildings associated with Lots 8, 9 and 12 follows. 5.3.1 North The VHC 8.1 tall open forest to the north of the proposed building envelopes exposes them to varying risk of direct flame, radiant heat, ember and spotting impact in the absence of additional mitigation measures being employed. The degree of separation offered to the VHC 8.1 hazard is the primary driver of the assigned level of risk and was determined with consideration to the Flamesol modelling output presented in Section 4. © 2022 20
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.