Attachment 2 - Engineer form 15
Attached to the e-mail OPW20/0117 - Information Response - 37 Mossman Court Noosa Heads.
Department of Housing and Public Works
Form 15—Compliance certificate
for building design or
Version 4 – July 2017
specification
NOTE: This is to be used for the purposes of section 10 of the Building Act 1975 and/or section 46 of the
Building Regulation 2006.
RESTRICTION: A building certifier (class B) can only give a compliance certificate about whether building work
complies with the BCA or a provision of the Queensland Development Code (QDC). A building certifier (Class B)
can not give a certificate regarding QDC boundary clearance and site cover provisions.
1. Property description Street address (include no., street, suburb/locality and postcode)
This section need only be 35-37 Mossman Court
completed if details of street
address and property description Noosa Heads Postcode 4567
are applicable.
E.g. in the case of Lot and plan details (attach list if necessary)
(standard/generic) pool design/shell Lots 82 & 83 N 21847
manufacture and/or patio and
carport systems this section may In which local government area is the land situated?
not be applicable. Noosa Council
The description must identify all
land the subject of the application.
The lot and plan details (e.g.
SP/RP) are shown on title
documents or a rates notice.
If the plan is not registered by title,
provide previous lot and plan
details.
2. Description of Proposed jetty consisting of hardwood timber piles, bearers, joists and decking.
component/s certified
Clearly describe the extent of work Class of building / structure: Class 10b
covered by this certificate, e.g. all
structural aspects of the steel roof Items not certified: Balustrading or Gates, Wall and Floor Claddings//Finishes
beams.
3. Basis of certification • AS 1170.1:2002 Dead and Live Loads and load Combinations
Detail the basis for giving the • AS 1720:2010 Timber Structures
certificate and the extent to which
tests, specifications, rules, • AS 2159:2009 Piling – Design and Installation
standards, codes of practice and other • AS 4997: 2005 Guidelines for the design of Maritime Structures
publications, were relied upon. • AS 4678:-2012 Earth Retaining Structures
• AS 1170.0: 2002 Structural Design Actions
• Schedule 3 – Coastal Protection & Management Regulation 2017
• Noosa Planning Scheme Policy 4 – Domestic marine uses outside of
Noosa Waters
Loading Criteria:
Jetty Live Loads: 2.0kPa
Moored Vessel (Max.) Length: 10.0m, Beam: 4.0m
Weight: 5,00kg Berthing Velocity: 0.25m/s
4. Reference documentation SCG Consulting Engineers Drawing numbers:- 30153-N, J1.A, J2, J3.A, J4.A, J5.A, J6.A, J7
Clearly identify any relevant
documentation, e.g. numbered
structural engineering plans.
LOCAL GOVERNMENT USE ONLY
Date received Reference Number/s
See the original
The page text is free to read. Viewing or downloading an original file needs an account.