PLANNING AND ENVIRONMENT COMMITTEE MEETING REPORT                           10 JUNE 2025


                   Walls located between the terrace areas are not approved and are to
                   be removed.
     CD 3.02 B       B     Elevation 02 – Thomas St / West prepared 26.02.2025
                           by Arkos Architects
     Amendments    The rooftop pergola structure is to be reduced to be no more than 2.2
                   metres in height above roof level. The pergola is not to be roofed or
                   covered with an impervious material.
                   The horizontal roof over stairs providing access to the roof top is not
                   approved and is to be amended to be reduced in height and to follow
                   the gradient of the stairs to reduce the appearance of a roofed area.
                   Any wall/s around the edge of the roof top terrace or on the roof area
                   are a maximum of 1.2 metres in height. A privacy wall is permitted
                   along the eastern side of the Roof Terrace 2 up to 1.7 metres in
                   height.
                   Any splash back around the pool is to be constructed from clear
                   glazing or similar.
                   Walls located between the terrace areas are not approved and are
                   to be removed.
     CD 3.03 B       B     Elevation 03 – East / Albert St prepared by 26.02.2025
                           Arkos Architects
     Amendments    The rooftop pergola structure is to be reduced to be no more than 2.2
                   metres in height above roof level. The pergola is not to be roofed or
                   covered with an impervious material.
                   The horizontal roof over stairs providing access to the roof top is not
                   approved and is to be amended to be reduced in height and to follow
                   the gradient of the stairs to reduce the appearance of a roofed area.
                   Any wall/s around the edge of the roof top terrace or on the roof area
                   are a maximum of 1.2 metres in height. A privacy wall is permitted
                   along the eastern side of the ‘Roof Terrace 2’ up to 1.7 metres in
                   height.
                   Any splash back around the pool is to be constructed from clear
                   glazing or similar.
                   Walls located between the terrace areas are not approved and are to
                   be removed.
     CD 3.04 B       B     Elevation 05 – South prepared by Arkos 26.02.2025
                           Architects
     Amendments    The rooftop pergola structure is to be reduced to be no more than 2.2
                   metres in height above roof level. The pergola is not to be roofed or
                   covered with an impervious material.
                   The horizontal roof over stairs providing access to the roof top is not
                   approved and is to be amended to be reduced in height and to follow
                   the gradient of the stairs to reduce the appearance of a roofed area.
                   Any wall/s around the edge of the roof top terrace or on the roof area
                   are a maximum of 1.2 metres in height. A privacy wall is permitted
                   along the eastern side of the ‘Roof Terrace 2’ up to 1.7 metres in
                   height.
                   Any splash back around the pool is to be constructed from clear
                   glazing or similar.
                   Walls located between the terrace areas are not approved and are to
                   be removed.
                   ‘Metal cladding with a profiled design’ to the southern elevation is not
                   approved. An alternative design treatment is required to be
                   developed and shown on the elevation.




                                                                               Page 4 of 9
Log in to download the original file

ATTACHMENT 1 - (MCU24_0074) - PLANNER'S REPORT.pdf · 215 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.