DRAWING SIZE — At
LOT 2 ON RP 214048
Level Datum AHD
Lukes Road, Cooroy Mountain
Survey information provided by
HEIGHT DATUM
24
YY A
THIS FOOTING IS FOUNDED So
BELOW CRITICAL DEPTH &
LINE AND IS STABLE. STABLE
PIERS OR UNDERPINNING FOUNDED
BELOW THE CRITICAL DEPTH LINE
WOULD BE NEEDED 10 SUPPORT
ANY FOOTING THAT IS FOUNDED
ABOVE THE CRITICAL DEPTH LINE.
CRITICAL DEPTH LINE
--~~ INDICATES PROPOSED SURFACE
43077
4189
/@D
FFL
ttt
x
TOP : 29.90
BTM : 29.15
H = 0.75m
—— SW/EX
oe RW
MAX WATTERSON & ASSOCIATES (MWA) |
B» UNSTABLE
Horizontal
ao
/
EXISTING STRUCTURE /O WELLING
INCLUDING NEIGHBOURING
ALLOTMENTS !
THE BUILDER/CONTRACTOR
SHALL CONFIRM ALL
RELEVANT LEVELS PRIOR TO
COMMENCING WORKS.
TRENCH.
NOTE:
THIS DETAIL ALSO EN 417.88
FOUNDATIONS ON NEIGHBOURING.
PROPERTIES. SHEET PILING MUST BE
INSTALLED WHERE EXISTING FOOTINGS WILL
BE FOUNDED ABOVE ANY EXCAVATION
CRITICAL DEPTH LINE
LEGEND
CONTOURS AND LEVELS TO AHD.
EXISTING SURFACE SPOT LEVELS.
INDICATES DEPTH OF CUT (NEGATIVE) OR
FILL (POSITIVE) AS NOTED
PROPOSED FINISHED FLOOR LEVEL
INDICATES AREA OF CUT
INDICATES AREA OF FILL
INDICATES PROPOSED RETAINING WALL
LEVEL & HEIGHTS
INDICATES LOCATION OF SECTION LINES,
REFER DRG OW3.3 FOR DETAILS
INDICATES OVERHEAD ELECTRICITY
SUPPLY LINE
INDICATES EXISTING SEWER LINE
INDICATES WATER MAIN APPROX
ALIGNMENT, BUILDER TO CONFIRM EXACT
LOCATION PRIOR TO WORKS
INDICATES TELSTRA LINE APPROX
ALIGNMENT, BUILDER TO CONFIRM EXACT
LOCATION PRIOR TO WORKS
INDICATES STORMWATER DRAIN EXISTING
AS NOTED
INDICATES POSITION OF RETAINING WALL
TO STRUCTURAL ENGINERS DETAIL.
www.dialbeforeyoudig.com.au
DIAL1100
BEFORE YOU DIG
7 Vy.
7 y
7
7
7
ff
J
THIS FOOTING WTHOU
PIERS IS "AD
ABOVE CRI OEP
LINE AND IS UNSTABLE.
LINE OF PROPOSED
—*— EXCAVATION OR OTHER -F
+"
9.08 418.73
448.18-—--~ ©
ra
<
RESIDENTIAL on
DEVEEOPMENT *
FFL |
122.000) —_|
HOUSE ELEVATION TABLE
Elevations Table
DRIVEWAY ELEVATION TABLE
Elevations Table
ee
:121.800
[2
,
cm
ED,
pC
2.26
fi
\enaea-o-y7
SITE PLAN — EARTHWORKS PLAN PART 1
Scale 1: 250
122.000
lA
ALL SERVICES SHOWN ON THIS PLAN INDICATIVE
ONLY CONTRACTOR TO LOCATE ALL SERVICES
PRIOR TO COMMENCING WORKS ON SITE. ALL
SERVICES ARE TO BE PROTECTED IN
ACCORDANCE WITH THE AUTHORITY
RESPONSIBLE FOR THE SERVICE
0.90
4
+!
EXISTING
TO BE DEMOLISHED
NOTE:
CUT/FILL LEVELS SHOWN REPRESENT THE FINISHED PAD
LEVEL (FPL) TO THE UNDERSIDE OF THE GROUND BEARING
SLABS AND PAVEMENTS AND INCLUDES THE CRUSHER
DUST OR ROAD BASE LAYERS TO BE PROVIDED UNDER THE
SLABS. ADDITIONAL LANDSCAPING FILL NOT INCLUDED.
SLAB AS DETAILED
IN STRUCTURAL
PAVEMENT AS
DETAILED ON DRG
DOCUMENTS OW4.1
FFL AS
w NOMINATED
Sesssasroso sl S 2
L 4 42 4/..LEVELLING LAYER NOMINATED. S
Number | Minimum Elevation | Maximum Elevation | Color Number | Minimum Elevation | Maximum Elevation | Color BUILDER TO MAINTAIN STABILITY PRIOR TO COMMENCING WORKS,
one oo feo cueoar seems | | AEE oem irs
2 -2.000 ~1,000 | 2 0.000 1.250 |
5 ~1.000 0.000 a DILAPIDATION REPORT:
4 0.000 1.000 SITE PREPARATION, EARTHWORKS & COMPACTION PRIOR TO ANY CONSTRUCTION
UNDERTAKE DILAPIDATION REPORT OF ALL
7m [so eee ares argu ge] [eee ens) wis
SPECIFICATIONS AND REQUIREMENTS OF TECTONIC SLOP
STABILITY ASSESMENET REPORT (PROJECT
26020-001-REVO-) DATED FEB 2026,
Cut/Fill Summary
Name Cut Factor Fill Factor 2d Area Cut Fill Net
DRIVEWAY VOLUME 1.000 1.000 1419.61sq.m 464.80 Cu. M. 116.06 Cu. M. 348.74 Cu. M.<Cut>
BUILDING VOLUME 1.000 1.000 5055.61sq.m 2910.22 Cu. M. 1628.11 Cu. M. 1282.10 Cu. M.<Cut>
STABLES VOLUME 1.000 1.000 3884.19sq.m 2070.83 Cu. M. 187.54 Cu. M. 1883.28 Cu. M.<Cut>
Totals 10359.41sq.m 5445.84 Cu. M, 1931.72 Cu. M. 3514.12 Cu. M.<Cut>
CL
7
KK FOOTING AS
DETAILED IN
STRUCTURAL
DOCUMENTS
( ye LEVELS DIAGRAM
TYPICAL SECTION 0
10m
—~
DRIVEWAY/CARPARK PAVEMENT
1:250 @ Al
1:500 @ A3
EX. SWPT
KE
EXISTING STORMWATER PIT
EX. SWMH EXISTING STORMWATER MANHOLE
EX. SMH EXISTING SEWER MANHOLE
EX. SCP EXISTING SEWER CONNECTION POIN
E.0.B. EXISTING EDGE OF BITUMEN
K&C EXISTING KERB & CHANNEL
NS.L. NATURAL SURFACE LEVEL
FH. FIRE HYDRANT anni?
5 TP s2h TELSTRA PIT +
1709 EP. ELECTRICAL PILLAR
KERB EXISTING KERBING
RCEW REINFORCED CONCRETE END WALL
SV STOP VALVE
W.M WATER METER 40
5 41
41228
3
4 4
ir
423.9"
+
424.20
+
4.22
425.60
* 426.70
54 427.10 c ot
KO
783” 490 38 yo
27.
Kr 61
gar att
i yan
pi? it 428.0" +127 8 + oh
+ $427.96
1280"
w ‘e +4279 —_—
5 gt er 412846
: 28.10 —___—
+ 39 ‘
421.98 +'?
gree arr 0.681 pet
* (238! >
f ~~ iw
8 :
LDP é
y Y /
430.09 é -0.271
y 4 J
BUILDING / fe.
128° / i )
< eg /
7S Y 4
£17837 a, / PJ 901
+ 128.29 ©, +e + / RC D 7 “
oe ed ‘yt, oPROPOSED g
SL 40 We / /
3 7~ ££ GYM 20
9,20 4 Re
: FFL
130.0007, . ,
129.80 Soy -
13084
aon’
T
NOOSA COUNCIL
APPROVED PLAN
MCU26/0012 & OPW26/0034
25 MAY 2026
Revision
Description
Date
Issue
FOR APPROVAL
DO NOT SCALE FROM THIS DRAWING
The design and associated details contained on this and associated
drawings are copyright and are not to be used or reproduced without
the written permission of SCG Consulting Engineers.
SCG HOLDINGS PTY LTD T/
O SCG
Ph (07) 5455
aptgcompany ABN 68 669.675 790
Unit 1/11 Project Ave,
Noosa Heads
email:[email protected]
web:www.scg-engineers.com
5604
Title:
EARTHWORKS PLAN PART 1
Project
111 LUKES RD,
COOROY MOUNTAIN
Date: Feb 2026 Drawn LR Design 1H
. Checked: Drg No. Re
fez (0577 -OW3.1) .
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Approved Plan - MCU26 0012 & OPW26 0034 (As Published).pdfRelated documentApplication case desk ↗
About this file
- File size
- 15.2 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.