DRAWING SIZE — At
HEIGHT DATUM
LOT 2 ON RP 214048
Level Datum AHD
Lukes Road, Cooroy Mountain
Survey information provided by
MAX WATTERSON & ASSOCIATES (MWA)
op, UNSTABLE
ey A
THIS FOOTING IS FOUNDED BQ
BELOW CRITICAL DEPTH
LINE AND IS STABLE.
PIERS OR UNDERPINNING FOUNDED
BELOW THE CRITICAL DEPTH LINE
WOULD BE NEEDED 10 SUPPORT
ANY FOOTING THAT IS FOUNDED
ABOVE THE CRITICAL DEPTH LINE.
CRITICAL DEPTH LINE
Se
24
EXISTING STRUCTURE /DWELLING
INCLUDING NEIGHBOURING
ALLOTMENTS
THE BUILDER/CONTRACTOR
SHALL CONFIRM ALL
RELEVANT LEVELS PRIOR TO
COMMENCING WORKS.
Horizontal
THIS FOOTING WITHOUT
PIERS IS FOUNDED
ABOVE CRITICAL DEPTH
LINE AND IS UNSTABLE.
LINE OF PROPOSED
—"— EXCAVATION OR OTHER
TRENCH.
——-
NOTE:
THIS DETAIL ALSO APPLIES TO EXISTING
FOUNDATIONS ON NEIGHBOURING
PROPERTIES. SHEET PILING MUST BE
INSTALLED WHERE EXISTING FOOTINGS WILL
BE FOUNDED ABOVE ANY EXCAVATION
— \Y/
CRITICAL DEPTH LINE
LEGEND
4g077
+189
/D
FFL
itt
1a
x
TOP : 29.90
BIM : 29.15
H = 0.75m
INDICATES PROPOSED SURFACE
CONTOURS AND LEVELS TO AHD.
EXISTING SURFACE SPOT LEVELS.
INDICATES DEPTH OF CUT (NEGATIVE) OR
FILL (POSITIVE) AS NOTED
PROPOSED FINISHED FLOOR LEVEL
INDICATES AREA OF CUT
INDICATES AREA OF FILL
INDICATES PROPOSED RETAINING WALL
LEVEL & HEIGHTS
INDICATES LOCATION OF SECTION LINES,
REFER DRG OW3.3 FOR DETAILS
INDICATES OVERHEAD ELECTRICITY
SUPPLY LINE
INDICATES EXISTING SEWER LINE
INDICATES WATER MAIN APPROX
ALIGNMENT, BUILDER TO CONFIRM EXACT
LOCATION PRIOR TO WORKS
INDICATES TELSTRA LINE APPROX
ALIGNMENT, BUILDER TO CONFIRM EXACT
LOCATION PRIOR TO WORKS
INDICATES STORMWATER DRAIN EXISTING
AS NOTED
INDICATES POSITION OF RETAINING WALL
TO STRUCTURAL ENGINERS DETAIL.
www.dialbeforeyoudig.com.au
BEFORE YOU DIG
STABLES ELEVATION TABLE
Elevations Table
DRIVEWAY ELEVATION TABLE
Elevations Table
20.08
SITE_PLAN
Scale 1: 250
PROPOSED
ARENA
FFL panes
119.200)
— EARTHWORKS PLAN PART 2
ALL SERVICES SHOWN ON THIS PLAN INDICATIVE
ONLY CONTRACTOR TO LOCATE ALL SERVICES
PRIOR TO COMMENCING WORKS ON SITE. ALL
SERVICES ARE TO BE PROTECTED IN
ACCORDANCE WITH THE AUTHORITY
RESPONSIBLE FOR THE SERVICE
+0
PROPOSED
STABLES
FFL
NOTE:
CUT/FILL LEVELS SHOWN REPRESENT THE FINISHED PAD
LEVEL (FPL) TO THE UNDERSIDE OF THE GROUND BEARING
SLABS AND PAVEMENTS AND INCLUDES THE CRUSHER
DUST OR ROAD BASE LAYERS T0 BE PROVIDED UNDER THE
SLABS. ADDITIONAL LANDSCAPING FILL NOT INCLUDED.
SLAB AS DETAILED
IN STRUCTURAL
DOCUMENTS
FFL AS
Ow4.1
Number | Minimum Elevation | Maximum Elevation | Color Number | Minimum Elevation | Maximum Elevation | Color Fr ALL NEIGHBOURING “CRUCTURES, PRO ERTAKE APIO TON REPORTS OF
1 1.483 0.000 Hl 1 1.892 o.oo ~=Ssd A ONS SHEgT TAL ALL NEIGHBORING DWELLINGS/STRUCTURES
2 0.000 1.000 | 2 0.000 1.250 ||
DILAPIDATION REPORT:
SITE PREPARATION, EARTHWORKS & COMPACTION PRIOR TO ANY CONSTRUCTION
SITE PREPARATION, EARTHWORKS, TEMPORARY BATTERS TOE MI IE NOY cope
& COMPACTION TO BE IN ACCORDANCE WITH THE NEIGHBORING DWELLINGS/ STRUCTURES.
SPECIFICATIONS AND REQUIREMENTS OF TECTONIC SLOP
STABILITY ASSESMENET REPORT (PROJECT
26020-001-REVO-) DATED FEB 2026,
Cut/Fill Summary
Name Cut Factor Fill Factor 2d Area Cut Fill Net
DRIVEWAY VOLUME 1.000 1.000 1419.61sq.m 464.80 Cu. M. 116.06 Cu. M. 348.74 Cu. M.<Cut>
BUILDING VOLUME 1.000 1.000 5055.61sq.m 2910.22 Cu. M. 1628.11 Cu. M. 1282.10 Cu. M.<Cut>
STABLES VOLUME 1.000 1.000 3884.19sq.m 2070.83 Cu. M. 187.54 Cu. M. 1883.28 Cu. M.<Cut>
Totals 10359.41sq.m 5445.84 Cu. M. 1931.72 Cu. M. 3514.12 Cu. M.<Cut>
@ a
‘9
la 4 4 4
=
* LEVELLING LAYER
KK FOOTING AS
DETAILED IN
STRUCTURAL
DOCUMENTS
FINISHED LEVELS DIAGRAM
TYPICAL SECTION
—
w NOMINATED.
a a A SL 4
____ FPL AS
NOMINATED.
PAVEMENT AS
DETAILED ON DRG
KE
EX. SWPT EXISTING STORMWATER PIT
EX. SWMH EXISTING STORMWATER MANHOLE
EX. SMH — EXISTING SEWER MANHOLE
EX. SCP EXISTING SEWER CONNECTION POINT
E.0.B. EXISTING EDGE OF BITUMEN
K&C EXISTING KERB & CHANNEL
NS.L. NATURAL SURFACE LEVEL
FH. FIRE HYDRANT
TP TELSTRA PIT
EP. ELECTRICAL PILLAR
KERB EXISTING KERBING
RCEW REINFORCED CONCRETE END WALL
SV STOP VALVE
W.M WATER METER
NOOSA COUNCIL
APPROVED PLAN
MCU26/0012 & OPW26/0034
25 MAY 2026
Revision
Description Date
Iss
* FOR APPROVAL
DO
NOT SCALE FROM THIS DRAWING
The design and associated details contained on this and associated
drawings are copyright and are not to be used or reproduced without
the written permission of SCG Consulting Engineers.
125
100
SCG HOLDINGS PTY LTD T/
O SCG
aptgcompany
Unit 1/11 Project Ave,
Noosa Heads
Ph (07) 5455 5604
email:[email protected]
web:www.scg-engineers.com
ABN 68 659 675 790
7
4S 7 7
CLS
DRIVEWAY/CARPARK PAVEMENT
10m
—~
Title:
EARTHWORKS PLAN PART 2
Project
111 LUKES RD,
COOROY MOUNTAIN
: Di Desi
Date Feb 2026 rawn LR esign 1H
Checked: Drg No. Rev.
1:250 @ Al elppeg 27698 ,
1:500 @ A3 ‘| T Harrington |) ~~ 0577 -OW3.2 .
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Approved Plan - MCU26 0012 & OPW26 0034 (As Published).pdfRelated documentApplication case desk ↗
About this file
- File size
- 15.2 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.