NOOSA COUNCIL IDAS Development Application Decision Notice                                                   4 of 10


        Any damage to a water main shall be rectified by Council. Any damage to a sewer main shall be
        undertaken by either Council or a Council approved contractor.

        In all cases, Council reserves the right to carry out rectification works in an emergency and where no
        reasonable attempt has been made to complete the rectification works as part of the development.

        All costs incurred by Council in any rectification works shall be repaid to Council prior to the endorsement
        of the Plan of Survey.
10.     The Assessment Manager for building work shall ensure that all other permits required by this permit have
        been obtained and outcomes from imposed conditions incorporated into the building plans prior to issue
        of a Development Permit for Building Works.
Civil Works
11.     All redundant vehicular crossings to the site shall be removed and replaced by kerb and channel and
        footpath paving in accordance.

12.     The existing access driveway at the rear of the sites shall be extended to the proposed common boundary
        of proposed Lots 3 and 4. The access driveway shall be:

        12.1. Constructed of similar materials as the existing driveway with a minimum width of 3.0 metres,

        12.2. Designed and constructed in accordance with the requirements of Council’s Planning Scheme
              Policy PSP05 – Engineering Design Standards – Roads, Drainage and Earthworks, shall reference
              where applicable to Council’s Standard Drawings and shall incorporate best engineering practice.

13.     All designs for engineering works involving the construction of sewerage reticulation shall be prepared in
        accordance with the requirements of Council's Planning Scheme Policy PSP06 – Engineering Design
        Standards – Water and Sewerage, shall reference where applicable to Council’s Standard Drawings and
        shall incorporate best engineering practice. To avoid conflict with underground pipes or services, all
        existing and proposed services required by the development shall be shown on the plans.

14.     A suitably qualified Registered Professional Engineer shall prepare engineering drawings and
        specifications for all engineering works that will become Council infrastructure, which shall be submitted in
        conjunction with an application for a Development Permit for Operational Works. In this regard a
        DXF/DWG file on GDA94 zone 56 grid of the proposed cadastre layout is to be submitted in conjunction
        with any application for Operational Works.

15.     To facilitate production of As Constructed drawings it is suggested that all design drawings are submitted
        in the Asset Design and As Constructed (ADAC) digital format. (Guidelines on the use of ADAC are
        available at www.adac.com.au).

16.     Prior to Council endorsing the Plan of Survey, a certificate from a registered Professional Civil Engineer
        shall be submitted to Council for each Development Permit for Operational Works issued pursuant to this
        permit. The engineer shall certify that he has supervised those works and that they have been completed
        in a workman like manner in accordance with good engineering practice and in accordance with that
        permit.

17.     As Constructed drawings and data shall be certified by a qualified experienced Civil Engineer for design
        intent, and a Licensed Surveyor shall certify the cadastre and the location, level and type of all services
        and structures. All of which shall be submitted to Council for checking and for Council’s records.
        The data must fully detail levels for all engineering works including but not limited to drainage structures,
        finished ground levels and pavement surface levels. The data shall be submitted in the Asset Design and
        As Constructed (ADAC) digital format.            (Guidelines on the use of ADAC are available at
        www.adac.com.au).

        Approval of works shall not be granted until all As Constructed information has been supplied and
        accepted by Council.
Water
18.     The site shall be connected to Council’s Water Supply and Sewerage reticulation systems to the Water
        and Sewerage design guidelines and the requirements of the Manager - Land Development, at no cost to
        Council.




NSC c:\docume~1\rhr\locals~1\temp\bcl technologies\easypdf 5\@bcl@cc01df72\@[email protected]

Used in these records

About this file

File size
43 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Decision Notice - 010.2007.00001490.001 [As Published].pdf · 43 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.