                                                         Engineering Report & Stormwater Management Plan
                                                 Date:          16/06/2014      Document No.:       14012-ENG-01.Docx

                                                  By:              AvT           Revision No.:               B


 DESCRIPTION                            Design Parameter                                         Notes
Developable Area                             5.064ha
                                   Service Station = 1460m2 = 15EP                     1.00 EP/100m2 GFA
                                      Self-Storage = 100m2 = 1EP                1.00 EP/100m2 GFA (Office Only)
                                      Tourist Park = 37du = 89EP                        2.40 EP/du (Units)
       EP
                                      Tourist Park = 320m2 = 4EP                   1.00 EP/100m2 GFA (Office)
                                       Future = 5800m2 = 58EP                               100 EP/ha
                                             TOTAL = 167EP
                                             = 200L/EP/day
     ADWF                                      = 200 x 167                           Noosa PIP DSS Table 3.2
                                              = 33400L/day
                                               = 5 x ADWF                        SEQ WS & S D&C Code - Design
    PWWF                                       = 5 x 33400
                                                                                      Criteria - Table 10
                                             = 167000L/day
                                               C2 x ADWF
                                       = (4.7 x (EP)-0.105) x ADWF               SEQ WS & S D&C Code - Design
     PDWF
                                      = (4.7 x (167)-0.105) x 33400                   Criteria - Table 10
                                              = 91720L/day
          Table 6.1:             Preliminary Sewer Pump Station Design

    Abbreviations:
    ADWF         Average Dry Weather Flow                     OPS            Operating Storage
    DSS          Desired Standard of Service                  PIP            Priority Infrastructure Plan
    du           Dwelling Unit                                PS             Pump Station
    ET           Equivalent Tenements                         PWWF           Peak Wet Weather Flow
    EP           Equivalent Populations                       PDWF           Peak Dry Weather Flow
    GFA          Gross Floor Area                             Q              Pump Rate
    N            Number of Starts per Hour

    After discussions with Noosa Council Engineers, vT Consulting Engineers were advised that as
    the sewer and water supply are to be taken over by Unitywater as of 1st July 2014, the
    proposed sewer design should meet Unitywater standards and requirements. Unitywater
    advised that the water supply and sewer demand factors used in the table above are to be
    taken from the Maroochy Plan (2000) Table 2 (a) which Unitywater has advised is suitable for
    the design of the pump station.

    For more details of the sewer reticulation refer to the engineering plans in Appendix B.

    Internal house drainage design for this proposed development will be by others.




    A PO Box 26, Carina Q 4152                                                                           21 | P a g e
    E [email protected]
    W www.vtce.com.au
Log in to download the original file

MCU14_0056 - Attachment H -Economic Needs Assessment.pdf · 12.3 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.