water quality code
Performance Outcomes Acceptable Outcomes
Editor’s note— PSP6 Engineering Design Standards Roads,
drainage and earthworks provides guidance on requirements for
preparing an Erosion Management Plan.
AO14.2
Construction works are designed and managed to restrict the
extent of clearing and soil exposure to the minimum necessary for
access, and safe construction at any one time.
Able to Comply
AO14.3
For buildings:
(a) upstream runoff is diverted around the construction site;
(b) sediment barriers are provided downslope of disturbed
areas to prevent sediment washing into gutters, drains and
waterways , wetlands or drainage lines either on or off the
site; and
(c) temporary or permanent downpipes are connected to the
stormwater system before laying the roof; or
(d) localised erosion is avoided by directing flow from
downpipes over nonerosive areas.
Not Applicable
AO14.4
Chemical flocculants used as part of an erosion and sediment
control plan do not harm the environmental values within
receiving waters.
Not Applicable
AO14.5
Appropriately sized litter containment areas, with provision for
sorting recyclables are provided for the type of litter expected to be
generated onsite. Not Applicable
Wastewater management and effluent disposal Table 9.4.8.3 Criteria for assessment (part)
Performance Outcomes Acceptable Outcomes
Wastewater management and effluent disposal
PO15 AO15
Development does not discharge wastewater unless it can be Wastewater (nonsewage) generated from the development is
demonstrated to not compromise environmental values of collected and contained onsite, and is:
waters and water quality objectives. (a) lawfully disposed to sewer; or
(b) transferred offsite for treatment/disposal to an
Editor’s Note—Environmental values of waters and water appropriately licenced facility;
quality objectives are prescribed in Schedule 1 of the reused onsite in a closedcycle irrigation scheme,
(c)
Environmental Protection (Water) Policy 2009. industrial processes, washing or cleaning or other
purpose; or
(d) treated to meet the drinking water supply environmental
values prior to release.
Not Applicable
Editor’s Note—The Plumbing and Drainage Act 2003 sets out
requirements for wastewater management.
PO16 AO16
Onsite effluent treatment and disposal systems are designed, An onsite effluent system and disposal area is:
constructed and managed to not compromise the environmental (a) not located on a slope greater than 1 in (10%);
values of waters and water quality objectives.
(b) not located at or below the 1% annual exceedance
NOOSA PLAN 2020 AMENDED AT 25 SEPTEMBER 2020 Page 6 of 7