Sam Hopper – Slope Stability Assessment and Geotechnical Report - Proposed Residence, 24 Arakon Crescent, Sunshine Beach
Lateral Capacity
Broms (1966) has related the values of Ks and d to effective angle of shearing resistance of
cohesionless soils and various pile materials, as shown in Table 7.
TABLE 7 VALUES OF KS
d Ks
Pile Material
Degrees Low Relative Density High Relative Density
Steel 20 0.5 1.0
Concrete ¾ 1.0 2.0
It should be noted that the calculated ultimate resistance of a given pile should also take into
account the installation effects of that particular type, i.e. whether displacement or non-
displacement pile performance can be expected.
7.2.6 Slab on Ground
General
Field and laboratory test results indicate that the existing natural soils are suitable for a
conventional slab on natural ground construction. In areas of any fill, localised pedestals would
be required to suspend the slab.
For constructability of the proposed slab, it is generally preferred to have the same type of slab
across the proposed development site.
Sub-Base
It is suggested that a layer of sub-base be provided under all concrete slabs. The sub-base
material should be compacted to a density not less than 95% of maximum dry density in
accordance with AS 1289 5.2.1 (Modified compaction). The sub-base is provided under a
concrete slab to:-
Provide a stable 'working platform' on which to operate construction equipment;
Facilitate the provision of a uniform bearing surface under the slab.
Sub-base material should be of good quality conforming to requirements (minimum) of Material
Type 2.4 as specified in the Queensland Department of Transport, Standard Specification MRS
11.05, Unbound Pavements (December, 1993).
7.2.7 Design Considerations
Inspections
It is recommended that inspections be undertaken by an experienced geotechnical engineer
from Soil Surveys Engineering following footing excavations to confirm the adequacy of the
founding soils. Inspections should be carried out prior to placement of reinforcing steel and
ordering of concrete.
Underground Services
Where footings are located adjacent to underground services, the footings should extend to
base a minimum of 200mm below the trench base level for a distance of 1.0m out from the
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Attachment C - Soil Survey Report.pdfRelated documentApplication case desk ↗
About this file
- File size
- 4.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.