INFORMATION PROVIDED BY POOL CONTRACTOR Y N UNKNOWN A SITE CLASSIFICATION HAS NOT BEEN PROVIDED FOR THIS POOL CONTRACTOR IS TO ENSURE THAT THE PROPOSED POOL IS
PROJECT. THE POOL BUILDER AND EXCAVATOR HAS A EITHER OUTSIDE THE TREE ZONE OF INFLUENCE OR PROVIDE
TREES PRESENT √ RESPONSIBILITY WHEN DETERMINING POOL LOCATIONS, DEPTHS PROTECTIVE MEASURES AGAINST THE TREE EFFECTS SUCH AS
UNCONTROLLED FILL PRESENT √ AND SETBACKS FROM EXISTING FOUNDATIONS, THAT THEY INSTALLING ROOT BARRIER OR SIMILAR. TREE ZOI IS "DISTANCE
CONFIRM THE SOIL PROFILE TO ENSURE EXCAVATION CAN BE FROM TREE = TREE HEIGHT X 2.0". ALTERNATIVELY THE POOL
SITE CONTOURS PROVIDED √
CARRIED OUT WITHOUT UNDERMINING THE EXISTING CONTRACTOR IS REQUIRED TO INFORM ENGINEER OF TREE
SEWER & STORMWATER SERVICE LOCATION PROVIDED √ FOUNDATIONS. E.G. SANDS REQ. 1 IN 2 ZONE OF INFLUENCE & LOCATION AND HEIGHTS FROM POOL ALONG WITH A SOIL LINDSAY CONSULTING PTY
LINDSAY CONSULTING PTY LTD
LTD
CLAYS REQUIRE 1 IN 1 ZONE OF INFLUENCE. ZONE OF REPORT TO DETERMINE THE SOIL EFFECTS APPLIED TO THE
SEWER & STORMWATER SERVICE DEPTHS PROVIDED √
POOL SHELL. THE POOL CONCRETE & REINFORCEMENT SHALL BE
INFLUENCES ARE DETERMINED FROM BASE OF EXCAVATION LINE. RPEQ 4928
SITE CLASSIFICATION REPORT PROVIDED √ DESIGNED TO SUPPORT INCREASED SURFACE MOVEMENT OFF. 2C/82 PARKER STREET, MAROOCHYDORE PH 54 792 118
DEPTHS & OUT OF GROUND HEIGHTS PROVIDED √ THIS DRAWING REMAINS THE PROPERTY OF
LINDSAY CONSULTING PTY LTD AND IS FOR
ADDITIONAL FEATURES INCLUDED (E.G. WATER FEATURE) √ THE SOLE USE OF THE CLIENT. NO PART
MAY BE USED IN PART OR WHOLE WITHOUT
NEIGHBOURING STRUCTURES OUTSIDE ZOI √ PRIOR EXPRESS WRITTEN CONSENT OF
STEEP SLOPE SITE EXCEEDING 15% √ LINDSAY CONSULTING PTY LTD
TRIGGERED LANDSLIDE HAZARD MAP √ CLIENT AND PROJECT DESCRIPTION
A SITE NOTE THAT THE FINAL LAYOUT, SHAPE AND SIZE SHALL BE ONTREND GROUP
CONFORMED ON-SITE PRIOR TO CONSTRUCTION, DRAWN TO PROPOSED POOL
INFORMATION PROVIDED BY CLIENT. LINDSAY CONSULTING DOES
NOT HOLD ANY RESPONSIBILITY FOR THE INFORMATION NOT
UNIT 2 NO.36 VENTURA ST
PROVIDED. SUNRISE BEACH
POOL FENCING IN ACCORDANCE WITH AS1926.1- 2007.
SELF LOCKING GATE LOCATIONS TO BE CONFIRMED ON-SITE DRAWING TITLE
SITE PLAN
SCALES
LINDSAY CONSULTING HAVE NOT BEEN PROVIDED WITH OR
CONSIDERED GEOTECHNICAL SLOPE STABILITY REPORT 1900 3000 3400
WHEN DESIGNING THE POOL FOUNDATIONS 1700 3200
SURVEY DATUM
.
ASSOCIATED CONSULTANTS
DEPTHS NOT
6000
PROVIDED
BACK BOUNDARY
WATER FEATURE BY OTHERS
NO LOAD TO BE PUT ON POOL WALL
PROPOSED UNITS
REVISION LIST
A ORIGINAL ISSUE 26/07/23
SITE PLAN
NOT TO SCALE
Computer File
230693PL.DWG
DRAWING NUMBER SHEET REV.
23-0693-PL1 1 A
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 3 pages
Page 2
NOTES d) Design - Design suitable for sites up to and including Class H (AS2870-2011)
1. STRUCTURAL - If pool is located in fill or aboveground refer to Structural Engineer.
a) Concrete - F'c = 25MPa at 28 days. 32MPa if within 1km of coastline - Drawing not to be used for pools in Exposure Classification C (AS2783)
LINDSAY CONSULTING PTY
LINDSAY CONSULTING PTY LTD
- Concrete shall comply with AS2783. - Walls have not been designed for cantilever walkways. LTD
- Concreting shall be carried out in one continuous operation by pneumatic spraying process. 2. CONSTRUCTION
- Shade concrete and keep moist for 7 days. a) Construction shall comply with AS2783.
RPEQ 4928
OFF. 2C/82 PARKER STREET, MAROOCHYDORE PH 54 792 118
- Exposure Classification (AS2783) - B2.
THIS DRAWING REMAINS THE PROPERTY OF
3. GENERAL LINDSAY CONSULTING PTY LTD AND IS FOR
b) Reinforcement
- Fy = 250MPa. S12 bars throughout, lap 400 where required. a) Ground water pressure shall be relieved by Hydrostatic valve as shown.
- Bars shall be tied securely in position. THE SOLE USE OF THE CLIENT. NO PART
b) Surface water shall be prevented from penetrating down beside pool wall by MAY BE USED IN PART OR WHOLE WITHOUT
- Cover shall be 65mm to vertical reinforcement to the inside face. grading surrounding areas away from the pool. PRIOR EXPRESS WRITTEN CONSENT OF
c) Security fencing shall be as required by the Local Authority. LINDSAY CONSULTING PTY LTD
c) Foundations - Excavation shall follow contours of pool shape. Where over excavation occurs fill with concrete. d) Finishes to pool surface shall be as detailed by Pool Contractor.
- Foundation material shall be uniform over entire pool base, if not refer to Engineer. e) All hydraulic equipment (eg. pump, filter, hydrostatic relief valve, skimmer box etc.) CLIENT AND PROJECT DESCRIPTION
- In clay or rocky ground use 75mm thick layer of 20mm nominal gravel under base. shall be as specified by the Pool Contractor
- Minimium safe bearing capacity - 100kPa ONTREND GROUP
- Pool walls shall be poured against undisturbed natural ground, if not refer to Structural Engineer.
900 wide x 75 thick slab all round with F52 PROPOSED POOL
fabric CP or pavers with cement stabilized UNIT 2 NO.36 VENTURA ST
A B filling sand. Refer Note 3(b).
SUNRISE BEACH
300 Total length 16700 MAX 300
Maximium surface area - 100m 2 Finish to Clients or
Contractors requirements DRAWING TITLE
200 150 Water Level TYPICAL REINFORCEMENT
3 /S12
DETAILS
in bond beam
H
600
Overall depth (D)
H
R/2
2250 MAX
SCALES
00
R4
R/2
R
60
100
0
T
DIA 200 Anti vortex Unreinforced cutoff wall
T
cover REQUIRED FOR
T
WALLS
REFER TABLE FOR Washed gravel to underside
(CLASS H2 & E SITES)
REINFORCEMENT of pool, refer Note 1(c)
A
300 SURVEY DATUM
BASE
Earth wire to reinforcement Dia 40 suction line 300
Connect to dwelling earth system
S12 Verticals @ 300 crs
to filter (Client option) .
75
S12 Horiz @ 300 crs Hydrostatic relief valve
300 Varies
75
600
Sump containing ASSOCIATED CONSULTANTS
100
crushed rock
275
275
nominal size 50 mm
Water Level 600 SQ
NOTE
B
500
Where pool wall height (H) exceeds
1200 but less than 1500
H
provide intermediate vertical S12 bars
00
as shown dotted. R6 LONGITUDINAL SECTION COPING VARIATION WET EDGE DETAIL
R/2
(ie. S12 bars in this area at 150 c/c) 00
R6
THIS IS BASED ON 150 THICK - REFER
300 Varies
TABLE FOR THICKER POOL SHELL 800 gth
ig ht len
Stra T
T
H
REVISION LIST
A ORIGINAL ISSUE 26/07/23
R/2
R
0
40
40
0
R
T
T
SECTION B-B SECTION A-A
Computer File
230693PL.DWG
DRAWING NUMBER SHEET REV.
23-0693-PL2 2 A
Page 3
Filter and Spa
pumping unit (optional) ABOVE GROUND CONCRETE POOL
VERTICAL REINFORCEMENT
Skimmer box Height Maximum Overall
SHELL WALL THICKNESS
POOL Above Depth
Ground(m) (Coping to Inside
LINDSAY CONSULTING PTY
LINDSAY CONSULTING PTY LTD
base face) 150mm 175mm 200mm 225mm 250mm LTD
Outlet to stormwater 0.6 m 1.2m S12 @ 300 S12 @ 300 S12 @ 300 S12 @ 300 S12 @ 300 RPEQ 4928
OFF. 2C/82 PARKER STREET, MAROOCHYDORE PH 54 792 118
drainage or sewer as 0.8 m 1.2m S12 @ 300 S12 @ 300 S12 @ 300 S12 @ 300 S12 @ 300
required by council THIS DRAWING REMAINS THE PROPERTY OF
1.0 m 1.2m S12 @ 300 S12 @ 300 S12 @ 300 S12 @ 300 S12 @ 300
LINDSAY CONSULTING PTY LTD AND IS FOR
1.2 m 1.35m S12 @ 150 S12 @ 300 S12 @ 300 S12 @ 300 S12 @ 300 THE SOLE USE OF THE CLIENT. NO PART
1.4 m 1.6m S12 @ 150 S12 @ 150 S12 @ 150 S12 @ 300 S12 @ 300 MAY BE USED IN PART OR WHOLE WITHOUT
PRIOR EXPRESS WRITTEN CONSENT OF
1.6 m 1.85m S12 @ 100 S12 @ 100 S12 @ 150 S12 @ 150 S12 @ 150
SCHEMATIC FOR WATER CIRCULATION 1.8 m 1.95m S12 @ 100 S12 @ 100 S12 @ 150 S12 @ 150
LINDSAY CONSULTING PTY LTD
CLIENT AND PROJECT DESCRIPTION
All pipework shall be Dia 40 uPVC Class 9 and all fittings shall 2.0 m 2.2m S12 @ 100 S12 @ 100
be uPVC Class 18 all to AS1475- 1994 (R2014) 2.1 m 2.3m S12 @ 100
ONTREND GROUP
PROPOSED POOL
THIS TABLE ONLY APPLIES FOR POOL BASE/WALL EMBEDDED 300 MM INTO NATURAL MATERIAL
300 Varies T UNIT 2 NO.36 VENTURA ST
HORIZONTAL REINFORCEMENT SUNRISE BEACH
3 treads at 300 Height Maximum Overall
SHELL WALL THICKNESS
Above Depth
Ground(m) (Coping to Inside
200 base face) 150mm 175mm 200mm 225mm 250mm
DRAWING TITLE
TYPICAL REINFORCEMENT
4 equal risers
0.6 m 1.2m S12 @ 300 S12 @ 250 S12 @ 225 S12 @ 300 S12 @ 300
DETAILS
500
0.8 m 1.2m S12 @ 300 S12 @ 250 S12 @ 225 S12 @ 300 S12 @ 300
1.0 m 1.2m S12 @ 150 S12 @ 140 S12 @ 100 S12 @ 150 S12 @ 150
1.2 m 1.35m S12 @ 150 S12 @ 140 S12 @ 100 S12 @ 150 S12 @ 150
1.4 m 1.6m S12 @ 150 S12 @ 140 S12 @ 100 S12 @ 150 S12 @ 150 SCALES
T
1.6 m 1.85m S12 @ 150 S12 @ 140 S12 @ 100 S12 @ 150 S12 @ 150
T
1.8 m 1.95m S12 @ 140 S12 @ 100 S12 @ 150 S12 @ 150
2.0 m 2.2m S12 @ 150 S12 @ 150
REFER TABLE 2.1 m
REFER TABLE 2.3m S12 @ 150
STEP DETAILS THIS TABLE ONLY APPLIES FOR POOL BASE/WALL EMBEDDED 300 MM INTO NATURAL MATERIAL
ALL REINFORCEMENT SPECIFICATION AS DERIVED FROM AS2783-1992
SPA DETAIL EF - EACH FACE
SURVEY DATUM
BELOW/INGROUND CONCRETE POOL
S12 - 200 EW CP HORIZONTAL REINFORCEMENT .
0
Maximum Overall
SHELL WALL THICKNESS
R5
250
300
Pool reinforcement Depth ASSOCIATED CONSULTANTS
(Coping to Inside
650
C C base face) 150mm 175mm 200mm 225mm 250mm
1000
1.2m S12 @ 300 S12 @ 250 S12 @ 225 S12 @ 300 S12 @ 300
1.2m S12 @ 300 S12 @ 250 S12 @ 225 S12 @ 300 S12 @ 300
REFER TABLE 1.2m S12 @ 300 S12 @ 250 S12 @ 225 S12 @ 300 S12 @ 300
TYP
400
1.35m S12 @ 300 S12 @ 250 S12 @ 225 S12 @ 300 S12 @ 300
1.6m S12 @ 300 S12 @ 250 S12 @ 225 S12 @ 300 S12 @ 300
1.85m S12 @ 300 S12 @ 250 S12 @ 225 S12 @ 300 S12 @ 300
BENCH DETAIL PLAN 1.95m S12 @ 250 S12 @ 225 S12 @ 300 S12 @ 300
2.2m S12 @ 300 S12 @ 300
SKIMMER BOX DETAIL 2.3m S12 @ 300
300 Profile of recess
to suit skimmer box.
Finish to Clients or ALL REINFORCEMENT SPECIFICATION AS DERIVED FROM AS2783-1992
Contractors requirements S12 - 200 EW CP EF - EACH FACE
REVISION LIST
A ORIGINAL ISSUE 26/07/23
MIN 150 Pool
S12 intermediates reinforcement
at 200 CRS
500 MAX
500
MIN 150
SECTION C-C
CANTILEVERED EDGE BEAM DETAIL SKIMMER BOX DETAIL Computer File
230693PL.DWG
DRAWING NUMBER SHEET REV.
23-0693-PL3 3 A
Page 4
S12 drop vertical bar
S12 corner bars @ 150 crs
N16 corner bars @ 200 crs (Below Ground)
350mm min lap
N16 corner bars @ 100 crs (Above Ground)
Radius 155mm
S12 Horizontal steel to be 350mm min lap
hooked with; Radius 155mm
40
50mm pin diameter min
LINDSAY CONSULTING PTY
LINDSAY CONSULTING PTY LTD
250mm lap LTD
30mm min cover so bars shall be
T
slightly rotated for min cover RPEQ 4928
65
T
OFF. 2C/82 PARKER STREET, MAROOCHYDORE PH 54 792 118
THIS DRAWING REMAINS THE PROPERTY OF
65
LINDSAY CONSULTING PTY LTD AND IS FOR
40 THE SOLE USE OF THE CLIENT. NO PART
MAY BE USED IN PART OR WHOLE WITHOUT
65 PRIOR EXPRESS WRITTEN CONSENT OF
WALL REINFORCEMENT AS PER
LINDSAY CONSULTING PTY LTD
DETAILS
65
WALL REINFORCEMENT AS PER CLIENT AND PROJECT DESCRIPTION
DETAILS
ONTREND GROUP
PROPOSED POOL
UNIT 2 NO.36 VENTURA ST
SUNRISE BEACH
DRAWING TITLE
TYPICAL REINFORCEMENT
DETAILS
SCALES
CORNER RADIUS LESS THAN 300mm
ALTERNATE CORNER RADIUS LESS THAN 300mm
Extra S12 1500 long
spaced 300 vertically
75 cover to inside face
S12 Verticals @ 200 crs
S12 Horiz @ 200 crs
R pro
SURVEY DATUM
(a
Line of
30 x.
p
0 )
excavation
.
T
ASSOCIATED CONSULTANTS
Position outside horizontal
reinforcing with 60 MIN cover
to excavated face
PLAN
WALL CORNER DETAIL
FOR RECTANGULAR POOLS
CORNER RADIUS 300mm OR GREATER
R pro
(a
30 x.
p
REVISION LIST
0 )
A ORIGINAL ISSUE 26/07/23
PLAN
BOND BEAM CORNER DETAIL Computer File
230693PL.DWG
FOR RECTANGULAR POOLS DRAWING NUMBER
23-0693-PL4
SHEET
4 A
REV.