NOTES d) Design - Design suitable for sites up to and including Class H (AS2870-2011)
1. STRUCTURAL - If pool is located in fill or aboveground refer to Structural Engineer.
a) Concrete - F'c = 25MPa at 28 days. 32MPa if within 1km of coastline - Drawing not to be used for pools in Exposure Classification C (AS2783)
LINDSAY CONSULTING PTY
LINDSAY CONSULTING PTY LTD
- Concrete shall comply with AS2783. - Walls have not been designed for cantilever walkways. LTD
- Concreting shall be carried out in one continuous operation by pneumatic spraying process. 2. CONSTRUCTION
- Shade concrete and keep moist for 7 days. a) Construction shall comply with AS2783.
RPEQ 4928
OFF. 2C/82 PARKER STREET, MAROOCHYDORE PH 54 792 118
- Exposure Classification (AS2783) - B2.
THIS DRAWING REMAINS THE PROPERTY OF
3. GENERAL LINDSAY CONSULTING PTY LTD AND IS FOR
b) Reinforcement
- Fy = 250MPa. S12 bars throughout, lap 400 where required. a) Ground water pressure shall be relieved by Hydrostatic valve as shown.
- Bars shall be tied securely in position. THE SOLE USE OF THE CLIENT. NO PART
b) Surface water shall be prevented from penetrating down beside pool wall by MAY BE USED IN PART OR WHOLE WITHOUT
- Cover shall be 65mm to vertical reinforcement to the inside face. grading surrounding areas away from the pool. PRIOR EXPRESS WRITTEN CONSENT OF
c) Security fencing shall be as required by the Local Authority. LINDSAY CONSULTING PTY LTD
c) Foundations - Excavation shall follow contours of pool shape. Where over excavation occurs fill with concrete. d) Finishes to pool surface shall be as detailed by Pool Contractor.
- Foundation material shall be uniform over entire pool base, if not refer to Engineer. e) All hydraulic equipment (eg. pump, filter, hydrostatic relief valve, skimmer box etc.) CLIENT AND PROJECT DESCRIPTION
- In clay or rocky ground use 75mm thick layer of 20mm nominal gravel under base. shall be as specified by the Pool Contractor
- Minimium safe bearing capacity - 100kPa ONTREND GROUP
- Pool walls shall be poured against undisturbed natural ground, if not refer to Structural Engineer.
900 wide x 75 thick slab all round with F52 PROPOSED POOL
fabric CP or pavers with cement stabilized UNIT 2 NO.36 VENTURA ST
A B filling sand. Refer Note 3(b).
SUNRISE BEACH
300 Total length 16700 MAX 300
Maximium surface area - 100m 2 Finish to Clients or
Contractors requirements DRAWING TITLE
200 150 Water Level TYPICAL REINFORCEMENT
3 /S12
DETAILS
in bond beam
H
600
Overall depth (D)
H
R/2
2250 MAX
SCALES
00
R4
R/2
R
60
100
0
T
DIA 200 Anti vortex Unreinforced cutoff wall
T
cover REQUIRED FOR
T
WALLS
REFER TABLE FOR Washed gravel to underside
(CLASS H2 & E SITES)
REINFORCEMENT of pool, refer Note 1(c)
A
300 SURVEY DATUM
BASE
Earth wire to reinforcement Dia 40 suction line 300
Connect to dwelling earth system
S12 Verticals @ 300 crs
to filter (Client option) .
75
S12 Horiz @ 300 crs Hydrostatic relief valve
300 Varies
75
600
Sump containing ASSOCIATED CONSULTANTS
100
crushed rock
275
275
nominal size 50 mm
Water Level 600 SQ
NOTE
B
500
Where pool wall height (H) exceeds
1200 but less than 1500
H
provide intermediate vertical S12 bars
00
as shown dotted. R6 LONGITUDINAL SECTION COPING VARIATION WET EDGE DETAIL
R/2
(ie. S12 bars in this area at 150 c/c) 00
R6
THIS IS BASED ON 150 THICK - REFER
300 Varies
TABLE FOR THICKER POOL SHELL 800 gth
ig ht len
Stra T
T
H
REVISION LIST
A ORIGINAL ISSUE 26/07/23
R/2
R
0
40
40
0
R
T
T
SECTION B-B SECTION A-A
Computer File
230693PL.DWG
DRAWING NUMBER SHEET REV.
23-0693-PL2 2 A
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Engineering Drawings.pdfRelated documentApplication case desk ↗
About this file
- File size
- 377 KB (small file)
- File type
No other editions are linked here.