Appendix A - Proposal Plans

of 10

Plans and drawings: the text below has words only, no drawings.

Log in to see the plans as drawn

Original PDF page 2, section 1. The text section number identifies this passage in the reader.

              G E N E R A L                            N O T E S

             GENERAL            NOTES                                                                       SITE        NOTES                                                                           ROOFWAT ER             DRAINAGE                                                              MANUFACTURES            SPECIFICATIONS

             DO NOT SCALE OFF DRAWINGS, ONLY USE FIGURED DIMENSION. BUILDER IS                              BUILDER TO CONFIRM LOCATIONS OF ALL EXISTING SERVICES BELOW &                              ALL ROOFWATER DRAINAGE SYSTEMS MUST BE CONNECTED TO A                                         ALL BUILDING PRODUCTS & MATERIALS THAT ARE USED ON SITE
             TO VERIFY ALL DIMENSIONS PRIOR TO COMMENCING AND                                               ABOVE GROUND LEVEL ON & ADJACENT TO THE SITE, PRIOR TO ANY                                 STORMWATER DRAINAGE SYSTEM COMPLYING WITH NCC 2022 BCA - VOL 2,                               MUST BE STORED CORRECTLY AS PER MANUFACTURERS
             WORK/CONSTRUCTION & ORDERING OF MATERIALS. BUILDER TO CONFIRM                                  BUILDING WORKS.                                                                            PART 3.3.5 DRAINAGE & AUSTRALIAN STANDARD AS/NZ 3500.                                         SPECIFICATIONS. REFER TO MANUFACTURERS SPECIFICATIONS FOR
             RL'S ON SITE PRIOR TO COMMENCEMENT OF EARTHWORKS.                                                                                                                                                                                                                                       MATERIAL AND PRODUCTS RECOMMENDED TO USE FOR ALL SITES
                                                                                                            THE FINISHED SURFACE IMMEDIATELY SURROUNDING THE BUILDING FOR                              THE ROOF DRAINAGE SYSTEM MUST BE PROVIDED WITH AN OVERFLOW TO                                 THAT ARE LOCATED WITHIN PROXIMITY TO SALT ENVIRONMENTS.
             ALL WORK PERFORMED SHALL ADHERE TO THE MINIMUM STANDARDS                                       A MINIMUM WIDTH OF 1000mm, SHALL BE PROVIDED WITH A MINIMUM                                PREVENT THE BACKFLOW OF WATER INTO THE BUILDING.
             SETOUT & PRESCRIBED BY THE RELEVANT AUSTRALIAN STANDARDS, THE                                  SLOPE OF 1 in 20 AWAY FROM THE BUILDING TO AN APPROVED DRAINAGE
             NATIONAL CONSTRUCTION CODE'S BUILDING CODE OF AUSTRALIA, AND THE                               SYSTEM AS PER NCC 2022 BCA - VOL 2, PART 3.3.3 SURFACE WATER                               THE AREA SPECIFIC RAINFALL INTENSITY MUST BE SELECTED FROM NCC
             REQUIREMENTS & REGULATIONS SETOUT BY ANY FEDERAL, STATE &                                      DRAINAGE.                                                                                  2022 BCA - VOL 2, PART 7.4.3 OR FROM AUSTRALIAN STANDARD AS/NZ3500.3                          DRIVEWAY / PATH           NOTES
             REGIONAL GOVERMENT.                                                                                                                                                                       OR FROM THE BUREAU OF METEOROLOGY 2016 RAINFALL DATA.
                                                                                                            SURFACE DRAINAGE IS TO DISCHARGE EVENLY WITHIN THE SITE &                                                                                                                                ALL SITE PAVING TO BE CONSTRUCTED IN ACCORDANCE WITH THE
             ALL BUILDING WORKS TO COMPLY WITH LOCAL AUTHORITIES EROSION AND                                WITHOUT NUISANCE TO ADJOINING PROPERTIES.                                                  GUTTERS & DOWNPIPES MUST BE SELECTED FROM NCC 2022 BCA - VOL 2,                               PUBLICATIONS
             SEDIMENT CONTROL STANDARDS. ALL SEDIMENT FENCING TO BE ERECTED                                                                                                                            PART 7.4.5 OR FROM AUSTRALIAN STANDARD AS/NZ3500.3.                                           CEMENT, CONCRETE & AGGREGATE AUSTRALIA - GUIDE TO
             ON SITE PRIOR TO COMMENCEMENT OF WORK.                                                         ALL SUBFLOOR AREAS MUST BE GRADED TO AVOID THE PONDING OF                                                                                                                                CONCRETE HOUSING 2007, PATHS & DRIVEWAYS & RESIDENTIAL
                                                                                                            WATER BENEATH THE BUILDING.                                                                EAVES GUTTERS MUST BE INSTALLED AT A FALL NOT LESS THAN 1 in 500                              CONCRETE DRIVEWAYS & PATHS - JULY 2005.
             ALL PLUMBING & DRAINAGE TO COMPLY WITH STANDARD SEWERAGE BY-                                                                                                                              WITH SUPPORT BRACKETS AT 1200mm MAXIMUM CENTRES.
             LAWS & REQUIREMENTS OF LOCAL AUTHORITY.                                                        UN-RETAINED BULK EARTHWORKS - SITE CUT & FILL BATTERS ARE NOT TO                                                                                                                         THE AREA BENEATH & ADJACENT TO DRIVEWAYS & PATHS TO BE
                                                                                                            EXCEED THE MAXIMUM SLOPES FOR THE RELEVENT SOIL CLASS SHOWN                                BOX GUTTERS MUST BE INSTALLED AT A FALL NOT LESS THAN 1 in 100, IN                            CLEARED OF ALL TOPSOIL & ORGANIC MATTER.
             BUILDER TO CONFIRM EXACT SITING AND ORIENTATION PRIOR TO                                       IN NCC 2022 BCA - VOL 2, PART 3.2. EARTHWORKS                                              ACCORDANCE WITH AUSTRALIAN STANDARD AS/NZ3500.3.
             CONSTRUCTION SETOUT. ALL BUILDING SETOUT AND CONFIRMATION OF                                                                                                                                                                                                                            PROVIDE A COMPACTED & LEVELLED LAYER OF 20mm MINIMUM
             SETBACKS AND HEIGHT TO BE CARRIED OUT BY A LICENSED SURVEYOR. NO                               TIMBER RETAINING WALLS TO HAVE 1000mm MAXIMUM HEIGHT. PROVIDE                              THE WIDTH OF VALLEY GUTTERS SHALL BE IN ACCORDANCE WITH                                       SAND: & AN OPTIONAL 0.2UM POLYETHYLENE MOISTURE BARRIER
             FOOTING, OR WALL TO ENCROACH THE TITLE BOUNDARY.                                               65mm DIA. AGG. DRAINS WITH GRANULAR BACKFILL. RETAINING WALLS &                            AUSTRALIAN STANDARD AS/NZ3500.3 & BUILDING CODE OF AUSTRALIA PART                             MAY BE PROVIDED UNDER THE SLAB IN SALINE AREAS, LAPPED &
                                                                                                            DRAINAGE SYSTEMS TO BE WHOLLY CONTAINED ON THE SUBJECT SITE.                               3.5.2. REFER TO ROOF SHEETING MANUFACTURERS SPECIFICATIONS FOR                                TAPED 200mm AT JOINTS.
             ALL WET AREAS TO BE CONSTRUCTED IN ACCORDANCE WITH NCC 2022 BCA -                              RETAINING WALLS GREATER THAN 1000mm IN HEIGHT SHALL BE                                     LIMITATIONS ON SHEET OVERHANGS INTO VALLEY GUTTERS. THE MAXIMUM
             VOL 2, PART 10.2 WET AREA AND WATERPROOFING.                                                   DESIGNED BY THE STRUCTURAL ENGINEER.                                                       ROOF CATCHMENT AREA FOR VALLEY GUTTERS IS 20sq.m. VALLEY                                      ALL PATHS & DRIVEWAYS SHALL HAVE A MINIMUM FALL OF 1 in 100
                                                                                                                                                                                                       GUTTERS ON ROOF PITCHED LOWER THAN 12.5 DEGREES MUST BE                                       (1%).
             PROVIDE APPROVED SMOKE ALARMS INSTALLED IN ACCORDANCE WITH NCC                                 BOUNDARY FENCES, INCLUDING HEIGHT OF ANY RETAINING WALLS                                   DESIGNED AS BOX GUTTERS.
             2022, BCA - VOL 2, PART 9.5 SMOKE ALARMS AND EVACUATION LIGHTING, BE                           UNDER, MUST NOT EXCEED 2000mm IN HEIGHT ABOVE EXISTING GROUND                                                                                                                            THE MAXIMUM GRADE OF PAVEMENTS SHALL NOT EXCEED 1 in 5
             INTERCONNECTED & TO COMPLY AUSTRALIAN STANDARD AS 3786.                                        LEVEL. REFER TO LOCAL AUTHORITY REGULATIONS PRIOR TO                                       DOWNPIPES MUST SERVE NOT MORE THAN 12 METRES OF GUTTER LENGTH                                 (20%). WHERE GRADES ARE NEAR THE MAXIMUM, A TRANSITION
                                                                                                            COMMENCING ANY WORKS & SEEK ANY REQUIRED APPROVALS.                                        FOR EACH DOWNPIPE WHICH MUST BE LOCATED AS CLOSE AS POSSIBLE                                  ZONE AT EITHER END MAY BE REQUIRED. REFER TO BUILDING
             ALL GLAZING TO COMPLY AND BE INSTALLED TO SATISFY THE NCC 2022 BCA -                                                                                                                      TO VALLEY GUTTERS.                                                                            CODE OF AUSTRALIA - VOLUME 1 PART D2.10 FOR GRADES TO
             VOL 2, PART 8 GLAZING                                                                                                                                                                                                                                                                   REQUIRED EXIT RAMPS.
                                                                                                                                                                                                       EAVES GUTTERS MUST BE PROVIDED WITH AN OVERFLOW SYSTEM WHERE
             ALL STAIRS, STEPS & RAMPS ARE DESIGNED & ARE TO BE CONSTRUCTED IN                              TERMITE             PROTECTION                                                             DOWNPIPES ARE LOCATED MORE THAN 1200mm FROM A VALLEY GUTTER.                                  ALL DRIVEWAYS, PATHS & CROSSOVERS BETWEEN THE PROPERTY
             ACCORDANCE WITH NCC 2022 BCA - VOL 2, PART 11.2 STAIRWAY AND RAMP                                                                                                                                                                                                                       BOUNDARY & THE KERBLINE ARE DESIGNED TO BE CONSTRUCTED
             CONSTRUCTION.                                                                                  ALL NEW BUILDING WORK AND/OR ALTERATIONS OF EXISTING                                                                                                                                     AS PER THE ALOCAL AUTHORITY REQUIREMENTS.
                                                                                                            BUILDING WORK IS TO BE TERMITE PROTECTED VIA PHYSICAL &/
             ALL BALUSTRADES & HANDRAILS ARE DESIGNED & ARE TO BE CONSTRUCTED                               CHEMICAL BARRIERS AS PER NCC 2022 BCA - VOL 2, PART 3.4                                                                                                                                  LIVABLE         HOUSING    DESIGN
                                                                                                                                                                                                       SUBFLOOR             VENTILATION
             IN ACCORDANCE WITH THE NCC 2022 BCA - VOL 2, PART 11.3 BARRIERS &                              TERMITE RISK MANAGEMENT.
             HANDRAILS.                                                                                                                                                                                PROVIDE SUBFLOOR VENTILATION TO THE MINUMUM STANDARD AS PER                                   DWELLING ACCESS TO BE PROVIDED IN ACCORDANCE WITH PARTS
                                                                                                            A DURABLE NOTICE IS REQUIRED AND MUST BE INSTALLED IN A                                    NCC 2022 BCA - VOL 2, PART 6.2.1 SUBFLOOR VENTILATION. IN ADDITION                            1.1 & 1.2 FROM THE LIVABLE HOUSING DESIGN.
             REFER TO STRUCTURAL ENGINEERS DRAWINGS & SPECIFICATIONS FOR                                    PROMINENT LOCATION SUCH AS THE METER BOX & IS TO BE                                        TO THE MINIMUM SUBFLOOR SPACE, THE SUBFLOOR SPACE MUST;
             SOILS REPORTS, FOOTING & SLAB DOCUMENTATION & OTHER REQUIRED                                   PERMANENTLY FIXED. THE INFORMATION TO BE DISPLAYED ON THE                                                                                                                                DWELLING ENTRANCE TO BE PROVIDED IN ACCORDANCE WITH
                                                                                                                                                                                                       - BE CLEARED OF ALL BUILDING DEBRIS AND VEGETATION
             STRUCTURAL DOCUMENTATION.                                                                      NOTICE IS AS PER NCC 2022 BCA - VOL 2, PART 3.4.3 DURABLE                                                                                                                                PARTS 2.1, 2.2, 2.3 & 2.4 FROM THE LIVABLE HOUSING DESIGN.
                                                                                                                                                                                                       - HAVE THE GROUND BENEATH THE SUSPENDED FLOOR GRADED IN
                                                                                                            NOTICE.                                                                                    ACCORDANCE WITH 3.3.3                                                                         INTERNAL DOORS & CORRIDORS TO BE PROVIDED IN ACCORDANCE
                                                                                                                                                                                                       - CONTAIN NO DEAD AIR SPACES                                                                  WITH PARTS 3.1, 3.2, 3.3 FROM THE LIVABLE HOUSING DESIGN.
                                                                                                            THEREAFTER THE OWNER TAKES ONTHE RESPONSIBILITY TO                                         - HAVE OPENINGS AS PER NCC 2022 BCA - VOL 2, FIGURE 6.2.1d
             BRICK / BLOCKWORK ARTICULATION JOINTS                                                          ORGANISE REGULAR INSPECTIONS WHICH MUST BE CARRIED OUT BY                                  - BE GRADED AS PER NCC 2022 BCA - VOL 2, PART 3.3.3 SURFACE                                   SANITARY COMPARTMENT TO BE PROVIDED IN ACCORDANCE WITH
                                                                                                            A QBCC-LICENSED CONTRACTOR WITH THE APPROPRIATE TERMITE                                    WATER DRAINAGE.
             BRICKWORK ARTICULATION JOINTS ARE TO BE INSTALLED                                                                                                                                                                                                                                       PARTS 4.1 & 4.2 FROM THE LIVABLE HOUSING DESIGN.
                                                                                                            MANAGEMENT LICENCE TO ENSURE TERMITES HAVE NOT BRIDGED                                     -THE CLEARANCE BETWEEN THE GROUND SURFACE & THE UNDERSIDE
             AT LOCATIONS OUTLINED IN NCC 2022 BCA - VOL 2, PART                                            THE BARRIER. IT IS RECOMMENDED THAT INSPECTIONS BE AT LEAST
             5.6.8 VERTICAL ARTICULATION JOINTS. BOTH BRICK &                                                                                                                                          OF THE FLOOR, MUST BE AS PER NCC 2022 - VOL 2 6.2.1 (1)b                                      SHOWER TO BE PROVIDED IN ACCORDANCE WITH PARTS 5.1 & 5.2
                                                                                                            EVERY 12 MONTHS, OR MORE OFTEN IN HIGH RISK AREAS. IT SHALL                                                                                                                              FROM THE LIVABLE HOUSING DESIGN.
             BLOCKWORK ARTICULATION JOINTS ARE TO BE INSTALLED                                              ALSO BE ADVISED THAT CAUTION BE TAKEN TO ENSURE THAT ALL
             AS PER AS 4773.2 MASONRY IN SMALL BUILDINGS                                                    PHYSICAL TERMITE BARRIERS BE CLEAR OF GARDEN BED &/OR SOIL
             CONSTRUCTION OR AS PER ENGINEERS SPECIFICATIONS.                                               BUILD UP & THAT ANY CHEMICAL BARRIERS INSTALLED REMAIN                                                                                                                                   REINFORCEMENT OF BATHROOM & SANITARY COMPARTMENT
                                                                                                            UNDISTURBED.                                                                                                                                                                             WALLS TO BE PROVIDED IN ACCORDANCE WITH PARTS 6.1 & 6.2
                                                                                                                                                                                                                                                                                                     FROM THE LIVABLE HOUSING DESIGN.



                                                                                                                                                                                                                                                                                                                                  I/WE HAVE CHECKED THE PLANS AND AGREE THAT THEY
                                                                                                                                                                                                                                                                                                                                  ACCURATELY DEPICT THE HOUSE FOR CONSTRUCTION.
                                                                                                                                                                                                                                                                                                                                 ANY VARIATIONS REQUESTED AFTER SIGNING WILL INCUR
                                                                                                                                                                                                                                                                                                                                   A PROCESSING FEE IN ADDITION TO THE COST OF THE
                                                                                                                                                                                                                                                                                                                                      VARIATION ITEM/S AND ANY FURTHER PLANS TO BE
                                                                                                                                                                                                                                                                                                                                                      PREPARED.
                                                                                                                                                                                                                                                                                                                                OWNER SIGNED: ............................................ DATE: ...................
                                                                                                                                                                                                                                                                                                                                OWNER SIGNED: ............................................ DATE: ...................

© COPYRIGHT. THIS DRAWING REMAINS THE PROPERTY OF G.J GARDNER HOMES & IS PROVIDED FOR THE USE AS DESCRIBED & MAY NOT BE USED OR REPRODUCED IN WHOLE OR IN PART WITHOUT WRITTEN PERMISSION. ANY LANDSCAPING (WHEN SHOWN) ARE FOR ILLUSTRATIVE PURPOSES ONLY AND DO NOT FORM PART OF ANY CONTRACT.                                BUILDER SIGNED: ..........................................   DATE: ..................




 G.J Gardner.
                                                                                                                                                            CLIENT:                                                                                                                      PAGES:   SHEET SIZE:    REV                    DESCRIPTION                                                  DATE
                                                 HOMES                       CUSTOM                                                                                                                                                                                                      02 OF 09    A3
                                                                                                                                                                                                                                                                                                                 A                    CONCEPT PLAN                                                 05.06.24
                                                                                                                                                            RICHARD GODWIN                                                                                                               JOB NUMBER: AU116-47    B                    CONCEPT PLAN                                                 11.06.24
             GJ NOOSA PTY LTD                                                                                                                               DRAWING TITLE:                                                  PROJECT: PROPOSED RESIDENCE                                  DRAWN BY:
                                                                                                                                                                                                                                                                                                                 C                    CONCEPT PLAN                                                 13.06.24

                   QLD                                                 © COPYRIGHT EXCLUSIVE                                   QLD                                                                                                                                                       JB

                QBCC 1303975                                           TO G.J GARDNER HOMES                                QBCC 15309561                    GENERAL NOTES 1 : 100                                           60 CRANK STREET, TEWANTIN                                    DATE:        13.06.24
Log in to download the original file

Appendix A - Proposal Plans.pdf · 4.0 MB (large file)

The download may take up to a minute.