PROJECT:

PROPOSED RESIDENTIAL ALTERATIONS

ADDRESS:

2/30 HASTINGS STREET,
NOOSA HEADS, QLD 4567

STAGE:

BUILDING APPROVAL

www.gtgroup.net.au

GT € R oe 6 S [email protected]
0410 063 172

(07) 3298 6938

 
Full text of the other 24 pages

Page 2

GENERAL NOTES :

TIMBER FRAMING DESIGNED IN ACCORDANCE WITH
NCC VOL. 2 PART 3.4 & AS.1684-2010. RESIDENTIAL TIMBER
FRAMED CONSTRUCTION

BLOCKWORK MASONRY DESIGNED IN ACCORDANCE WITH
SINGLE LEAF MASONRY - C.M.A.A. (CM02-2014).

MASONRY CONSTRUCTION TO COMPLY WITH NCC VOL. 2 PART
3.3 & AS.3700-2011, MASONRY STRUCTURES).

PLYWOOD BRACING DESIGNED IN ACCORDANCE WITH
STRUCTURAL PLYWOOD WALL BRACING - P.A.A.
(COMPLIES WITH AS.1684.2-2010).

STEEL SECTIONS DESIGNED IN ACCORDANCE WITH STRUCTURAL
STEEL IN HOUSING 'THIRD EDITION’

(COMPLIES WITH AS4100-1998 STEEL STRUCTURES).

WIND LOADING CALCULATIONS IN ACCORDANCE WITH
AS.4055-2012. WIND LOADS FOR HOUSING

STORM WATER DRAINAGE TO COMPLY WITH NCC VOL. 2 PART
3.1.2 & AS/NZS.3500.3-2003 OR AS.3500.5-2000 AND COUNCIL
REQUIREMENTS.

TERMITE PROTECTION TO COMPLY WITH NCC VOL. 2 PART 3.1.3 &
AS.3660.1-2000 AND MANUFACTURER'S SPECIFICATIONS.

SUB-FLOOR VENTILATION MUST COMPLY WITH NCC VOL. 2 PART
3.4.1. *400mm MIN. CLEARANCE TO UNDERSIDE OF LOWEST
TIMBER MEMBER*.

ROOF & WALL CLADDING AND GUTTERS & DOWNPIPES TO
COMPLY WITH NCC VOL. 2 PART 3.5

GLAZING TO COMPLY WITH NCC VOL. 2 PART 3.6 &
AS.2047-2014 & AS.1288-2006.

SMOKE ALARMS MUST COMPLY WITH THE REQUIREMENTS OF
THE NCC VOL. 2 PART 3.7.2 AND AS.3786-2014. *MUST BE HARD
WIRED TO MAINS POWER*.

ALL WET AREAS TO COMPLY WITH NCC VOL. 2 PART 3.8.1 &
AS.3740-2010.

W.C. DOOR TO COMPLY WITH NCC VOL. 2 PART 3.8.3.3.
LIGHTING TO COMPLY WITH NCC VOL. 2 PART 3.8.4
VENTILATION TO COMPLY WITH NCC VOL. 2 PART 3.8.5

SOUND INSULATION TO COMPLY WITH NCC VOL. 2 PART 3.8.6
TREADS & RISERS TO COMPLY WITH NCC PART 3.9.1
BALUSTRADE & HANDRAILS TO COMPLY WITH NCC PART 3.9.2 &
ASINZS.1170.1-2002.

SWIMMING POOL FENCE/ GATE TO COMPLY WITH NCC VOL. 2
PART 3.9.3, AS.1926.1-2007 & QDC MP3.4.

ENERGY EFFICIENCY TO COMPLY WITH NCC VOL. 2 PART 3.12 OR
RECOGNISED ENERGY RATING SYSTEM.

ALL RELEVANT WORKS TO COMPLY WITH THE NATIONAL
CONSTRUCTION CODE (NCC) - BUILDING CODE OF AUSTRALIA -
CLASS 1 AND CLASS 10 BUILDINGS.

ALL ANCILLARY WORKS TO BE UNDERTAKEN IN ACCORDANCE
WITH THE MANUFACTURERS SPECIFICATION

SUSTAINABLE HOUSING REQUIREMENTS:

NEW DWELLING REQUIREMENTS

THE LAWS APPLY TO NEW HOUSES (CLASS 1a), TOWNHOUSES (CLASS 1b),
AND MAJOR RENOVATIONS. A NUMBER OF NEW LAWS CAME INTO EFFECT
ON 26TH NOV. 2010 WHICH REPLACES THE EXISTING VERSION OF MP 4.1
PUBLISHED ON 30TH JULY 2010.

THIS GUIDELINE COVERS THE REQUIREMENTS FOR (CLIMATE ZONE 3):
* 6-STAR (CLASS 1 BUILDINGS)
[5-STAR MIN SOFTWARE RATING + OPTIONAL CREDITS]
ENERGY EQUIVALENCE FOR NEW HOUSES AND TOWNHOUSES ;
* OPTIONAL CREDITS
FOR COVERED OUTDOOR LIVING AREAS, SUCH AS DECKS AND
VERANDAHS AND;
+ ENERGY EFFICIENT LIGHTING
FOR NEW HOUSES, TOWNHOUSES ENERGY EFFICIENT LIGHTING
FOR A MINIMUM OF 80% FLOOR AREA

ENERGY EFFICIENT FIXTURES REQUIREMENTS

IN CLASS 1a, CLASS 1b AND CLASS 2 BUILDINGS:

+ LIGHT FITTINGS

MUST BE ENERGY EFFICIENT LIGHTING FOR A MINIMUM OF 80%
OF THE TOTAL INTERNAL FLOOR AREA. ENERGY EFFICIENT
LIGHTING: INCLUDES FLUORESCENT AND COMPACT
FLUORESCENT LIGHTS. IT DOES NOT INCLUDE INCANDESCENT
OR HALOGEN.

+ AIR CONDITIONERS

NEW AND REPLACEMENT AIR-CONDITIONERS MUST HAVE AN
E.E.R. OF AT LEAST 2.9.

+ HOT WATER SYSTEMS

HOT WATER SYSTEMS MUST COMPLY WITHE QUEENSLAND
PLUMBING AND WASTE WATER CODE

A SUITABLE HOT WATER SYSTEM INCLUDES:

(A) A GAS HOT WATER SYSTEM WITH A FIVE STAR ENERGY
RATING; OR

(B) A HEAT PUMP OR A SOLAR HOT WATER SYSTEM WHERE:
(I) IN A BUILDING WITH 3 OR MORE BEDROOMS,

THE HOT WATER SYSTEM, MUST BE ELIGIBLE TO

RECEIVE AT LEAST 22 RENEWABLE ENERGY

CERTIFICATES; OR

(II) IN A BUILDING WITH 1 OR 2 BEDROOMS THE HOT

WATER SYSTEM MUST BE ELIGIBLE TO RECEIVE AT

LEAST 14 RENEWABLE ENERGY CERTIFICATES.

WATER CONSERVATIVE FIXTURE REQUIREMENTS

THE FOLLOWING WATER CONSERVATION FIXTURES MUST BE
INSTALLED

THROUGHOUT THE DWELLING:

+ WATER PRESSURE

WATER PRESSURE LIMITING: (TO RETICULATED MAINS WATER
SUPPLY AREAS ONLY IF REQUIRED BY LOCAL GOVT.)

THE MAXIMUM PRESSURE LEVEL OF WATER FROM ANY OUTLET
WITHIN THE PROPERTY BOUNDARIES MUST NOT EXCEED S00KPA.
+ TOILETS

DUAL FLUSH TOILETS: A TOILET MUST HAVE A DUAL FLUSH
CAPACITY THAT DOES NOT EXCEED 6 LITRES ON FULL FLUSH
AND 3 LITRES ON HALF FLUSH.

* TAPWARE

MIN. 3-STAR WELS RATED FOR KITCH. SINKS, BASINS AND
LAUNDRY TUBS.

+ SHOWER HEADS

TO RETICULATED MAINS WATER SUPPLY AREAS ONLY, TO BE
3 STAR RATING UNDER THE WATER EFFICIENCY LABELLING
SCHEME (WELS) OR AAA RATING WHEN ASSESSED AGAINST
AS/NZ 6400:2005 WATER EFFICIENT PRODUCTS - RATING AND
LABELLING.

REFER: Queensland Development Code Mandatory Part 4.1 Sustainable buildings
Guideline-version 12th November 2010 FOR ADDITIONAL SPECIFICS.

WORKPLACE HEALTH AND SAFTEY
REQUIREMENTS:

EXCAVATION AND TRENCHES
BEFORE EXCAVATION WORK IS CARRIED OUT, THE RELEVANT PERSON
OR PRINCIPAL CONTRACTOR, FOR CONSTRUCTION WORK, MUST FIND
OUT WHAT UNDERGROUND SERVICES EXIST IN THE AREA, AND OTHER
RELEVANT INFORMATION
A RELEVANT PERSON MUST IMPLEMENT ANY CONTROL MEASURES
NECESSARY TO PREVENT RISK:

(a) AN EXCAVATION COLLAPSING,

(b) OBJECTS FALLING INTO AN EXCAVATION,

(c) APERSON FALLING INTO AN EXCAVATION,

(d) SUBSTANCE EXPOSURE IN AN EXCAVATION,

(ie. CARBON MONOXIDE FROM PLANT).

(e) FROM THE COLLAPSE OF ANOTHER STRUCTURE

(ie. ADJOINING BUILDING OR ROAD).
TRENCHES
BATTERING AND SHORING FOR TRENCHES TO BE IN ACCORDANCE
WITH WORKPLACE HEALTH AND SAFTEY REQUIREMENTS.
WRITTEN APPROVAL TO VARY THE BENCHING AND BATTERING
REQUIREMENTS MAY BE OBTAINED FROM AN ENGINEER. THE
APPROVAL MUST BE KEPT ON SITE AT ALL TIMES.
LADDERS USED FOR ACCESS MUST BE NO MORE THAN 9 METRES
APART IN THE AREA
OF THE TRENCH WHERE WORK WILL BE CARRIED OUT.

WORK AT HEIGHTS

RISKS MUST BE MANAGED IF A PERSON COULD FALL.

FACTORS SUCH AS THE TYPE OF ACTIVITY BEING CARRIED OUT
SHOULD BE TAKEN INTO CONSIDERATION TO ESTABLISH THE DEGREE
OF RISK.

CONTROL MEASURES USED TO MANAGE RISKS MUST COMPLY WITH
REGULATORY REQUIREMENTS.

RELEVANT PEOPLE CARRYING OUT WORK AS OUTLINED IN THE
WORKPLACE HEALTH AND SAFTEY REQUIREMENTS MUST:

(a) PREVENT A FALL; OR

(b) IF PREVENTION IS NOT POSSIBLE, ARREST THE FALL AND PREVENT
OR MINIMISE THE RISK OF DEATH OR INJURY FROM THE ARREST OF
THE FALL.

LADDERS, TRESTLES AND SCAFFOLDING

RELEVANT PEOPLE MUST PREVENT OR MINIMISE RISKS FROM USING A
LADDER.

RELEVANT PEOPLE MUST PREVENT OR MINIMISE RISKS FROM
WORKING ON A PLATFORM SUPPORTED BY A TRESTLE LADDER.

ALL LADDERS, TRESTLES AND SCAFFOLDING TO BE IN ACCORDANCE

WITH WORKPLACE HEALTH AND SAFTEY REQUIREMENTS.

PROTECTION FROM FALLING OBJECTS

PRINCIPAL CONTRACTORS AND RELEVANT PEOPLE MUST TAKE
PRECAUTIONS TO ENSURE THAT OBJECTS DO NOT FALL ONTO OR HIT
PEOPLE DOING CONSTRUCTION WORK AND PEOPLE IN ADJOINING
AREAS.

PRINCIPAL CONTRACTORS MUST ASSESS THE RISK FROM FALLING
OBJECTS AND USE CONTROLS TO PREVENT OR MINIMISE THE RISKS
THE CONTROLS CHOSEN MUST COMPLY WITH ANY REGULATORY
REQUIREMENTS.

DEMOLITION WORK AND ASBESTOS REMOVAL

DEMOLITION WORK OR ASBESTOS REMOVAL WORK (PRESCRIBED
ACTIVITIES) ARE NOW CONSIDERED AS CONSTRUCTION WORK.

PEOPLE PERFORMING THIS TYPE OF WORK MUST NOW COMPLY WITH
THE CONSTRUCTION RELATED REGULATIONS.

DEMOLITION WORK INCLUDES THE:
(a) DEMOLITION OR SYSTEMATIC DISMANTLING OF A BUILDING OR
OTHER STRUCTURE, OR PART OF A BUILDING OR OTHER STRUCTURE
(b) NOT INCLUDING THE SYSTEMATIC DISMANTLING OF A PART OF A
BUILDING OR OTHER STRUCTURE FOR ALTERATION, MAINTENANCE,
REMODELLING OR REPAIR

DEMOLITION WORK INVOLVING THE REMOVAL OF ASBESTOS
MATERIALS, INCLUDING FIBRO SHEETING, NEEDS EXTRA SAFETY
PRECAUTIONS.

ASBESTOS REMOVAL WORK MUST BE DONE IN ACCORDANCE WITH THE

NATIONAL CODE OF PRACTICE FOR THE SAFE REMOVAL OF
ASBESTOS 2ND EDITION [NOHSC:2002 (2005).

FLOOD HAZARD REQUIREMENTS:

FLOOD HAZARD AREA

AREAS SUBJECT TO FLOODING ARE TO COMPLY WITH QDC MP3.5 AND

THE NATIONAL FLOOD STANDARD, WHICH INCLUDES THE FOLLOWING:
+ STRUCTURAL ENGINEER TO PROVIDE CONFIRMATION THAT
THE FOOTING, SLAB AND SUBFLOOR HAS BEEN DESIGNED TO.
MEET FLOOD ACTIONS SPECIFIED IN SECTION 2.3 OF THE
NATIONAL FLOOD STANDARD.
+ STRUCTURAL ENGINEER TO SPECIFY THE NECESSARY
DURABILITY AND CORROSION PROTECTION OF MATERIALS
LOCATED BELOW THE DEFINED FLOOD HAZARD LEVEL, IN
ACCORDANCE WITH SECTION 2.8 OF THE FLOOD HAZARD CODE.
+ ELECTRICAL SWITCHES ARE TO BE PLACED ABOVE THE
FLOOD HAZARD LEVEL.
+ ELECTRICAL CONDUITS AND CABLES INSTALLED BELOW THE

FLOOD HAZARD LEVEL MUST BE WATERPROOFED OR PLACED

IN WATERPROOFED ENCLOSURES.

+ UTILITIES SUCH AS METERBOARDS, HOT WATER SYSTEMS
AND GAS BOTTLES ARE TO BE LOCATED ABOVE THE FLOOD
HAZARD LEVEL.
+ SANITARY DRAINAGE SYSTEM TO BE PROTECTED FROM
BACKFLOW USING A REFLUX VALVE FITTED BETWEEN THE
BUILDING AND SEWER CONNECTION POINT.

DRAINAGE DEFICIENT AREA

SITE TO BE FILLED AND GRADED TO LEVELS AS PER FIGURE 2 OF
SUNSHINE COAST REGIONAL COUNCIL'S FLOOD REPORT. LICENSED
BUILDING SURVEYOR TO PROVIDE EVIDENCE THAT THE MODIFIED SITE
SURFACE LEVELS HAVE BEEN CONSTRUCTED IN ACCORDANCE WITH
THE REPORT.

 

THs |S ACONPUTER GENERATED DRAWING, DO NOT auenD ey Hav, | AMENDMENTS
4. TH ul PI
2. THIS DRAWING SHOWS DESIGN INTENT ONLY. ALL DIMENSIONS AND | —e¥_DATE_DESCRPTION

PROJECT

ey FOR APPROVAL

 

SETOUTS ARE TO BE CHECKED ON SITE PRIOR TO CONSTRUCTION. A_ ]17.08.2023] ISSUE FOR BUILDING APPROVAL
3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHIN THE DRAWINGS B | 14.01.2025 | PROJECT SCOPE ADJUSTMENTS:
[ARE TO BE REPORTED TO THE DESIGNER PRIOR TO CONSTRUCTION
4, DO NOT SCALE THIS DRAWING

COPYRIGHT:
(© GT GROUP BUILDING DESIGN. THESE DRAWINGS ARE PROTECTED BY
THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED
WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.

ce PROPOSED RESIDENTIAL ALTERATIONS AUG 2023
ce ADDRESS: PROJECT NO.
2/30 HASTINGS STREET, NOOSA HEADS QLD 4567 22008
[auor:¢s | awe

| ORIGINAL SHEET SIZE: A3 (420x207mm] GENERAL NOTES

DRAWING CREATED

‘SCALE @A3

www.gtgroup.net.qau
[email protected]
ere RPP

(07) 3298 6938

GT GROUP

 

 

Page 3

 
  
 
 
 
 
   
  
  
  
 
  
  
 
 
 
  

NOOSA HEADS MAIN BEACH

 

BAY VILLAGE SHOPPING CENTRE
SUBJECT SITE. LOT 2

 

 

THE HASTINGS. REFER
SITE PLAN BELOW

THE SEBEL

 

WEYBA CREEK

a. 4 ~ =

4OPPING CENTRE

7

EXISTING A 3 'SEBEL' BUILDING

——_

7

5

ae o ¢<
7 | ¥ ‘ SITE PLAN
: : . mi . SCALE 1:500

 

SITE DATA
RPD

LOTIPLAN: 2/GTP1154

PARISH OF WEYBA

COUNTY OF MARCH

LOCAL GOVERNMENT: NOOSA SHIRE COUNCIL
LOCALITY: NOOSA HEADS

SEGMENT/PARCEL: 30824/40

AREA CALCULATIONS

 

OVERALL SITE AREA: 4933 SQM
SUBJECT SITE AREA: 88 SQM
PROPOSED BUILDING GFA: 147 SQM

PROPOSED BUILDING SITE COVER: 64 SQM

LANDSCAPING TO SUBJECT SITE. 35 SQM

 

 

 

— SUBJECT SITE

SHADED

   

 

NOTES: AMENDMENTS PROJECT

 

 

1, THIS IS A COMPUTER GENERATED DRAWING, DONOT AMEND BY HAND.| Rey DATE DESCRIPTION BY
2. THIS DRAWING SHOWS DESIGN INTENT ONLY. ALL DIMENSIONS AND

SETOUTS ARE TO BE CHECKED ON SITE PRIOR TOCONSTRUCTION. | A ] 17.08.2023] ISSUE FOR BUILDING APPROVAL a PROPOSED RESIDENTIAL ALTERATIONS
3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHIN THE DRAWINGS B 14.01.2025) PROJECT SCOPE ADJUSTMENTS GB ADDRESS

ARE TO BE REPORTED TO THE DESIGNER PRIOR TO CONSTRUCTION.
4, DO NOT SCALE THIS DRAWING.

‘COPYRIGHT: | AUTHOR: GB DRAWING

‘© GT GROUP BULDING DESIGN. THESE DRAWINGS ARE PROTECTED BY
THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED | ORIGINAL SHEET SIZE: A3[420%297mm] LOCALITY AND SITE PLAN

WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.

2/30 HASTINGS STREET, NOOSA HEADS QLD 4567

  
  

 
   
 

 
 

DRAWING CREATED SCALE @A3

AUG 2028 4800

PROJECT NO, REVISION www.gtgroup.net.au
22048 B GT G ie @ lg 2 [email protected]

   
 

PST
(OD REE CKE)

  

DWG, NO,

A001

  

Page 4

NOTE:

THESE DRAWINGS ARE DESIGN CONCEPTS
ONLY AND SHALL NOT BE USED IN ANY
WAY FOR STRUCTURAL PURPOSES. REFER
TO STRUCTURAL ENGINEER'S DETAILS
FOR ALL MEMBER SIZES, SPECIFICATIONS
AND SITE SPECIFIC STRUCTURAL
REQUIREMENTS.

 

 

Parwn>

 

4
q

 

 
     
 

 

DP qcoy | | {COL
(EXTG.)EXTG] 7 | — 7tEXTE)

BOUNDARY
(DEDICATED LOT
EXCLUSIVE USE AREA)

ADJOINING
VILLA

ROADWAY
ay

BOUNDARY,

 

 

 

 

|
|
BOUNDARY

 

 

COL STEEL COLUMN UNLESS NOTED OTHERWISE, ALL EXISTING 4. ALL CONSTRUCTION WORK UNDERTAKEN
BUILT WORKS ARE TO REMAIN. FOR FURTHER IS TO COMPLY WITH THE NATIONAL
CLARIFICATION ON EXTENT OF DEMOLITION CONSTRUCTION CODE (BCA), RELEVANT
WORKS, REFER TO PROPOSED FLOOR PLAN FOR AUSTRALIAN STANDARDS AND
PROPOSED RECONFIGURATION LAYOUT, WALL APPLICABLE LOCAL AUTHORITY
SETOUT DIMENSIONS AND OPENING LOCATIONS. REQUIREMENTS.
2. ALL SETBACK/SETOUT DIMENSIONS ARE
TO BE CHECKED AND VERIFIED ON SITE
PRIOR TO CONSTRUCTION.
NOTE: DEMOLITION NOTES
ROOM DIMENSIONS DEMOLISH EXISTING WALLS TO EXTENT SHOWN.
SHOWN ARE TO DEMOLISH EXISTING DOORS AND WINDOWS.
DEMOLISH EXISTING STAIRS AND HANDRAIL.
ADJOINING FINISHED WALL FACES. DEMOLISH EXISTING CONCRETE GROUND SLAB.
| DEMOLISH EXISTING SCREEN STRUCTURES.
VILLA o— —- —_ DEMOLISH EXISTING BRACING FRAMES. NOTE:
CONFIRM SUFFICIENT RECTIFICATION WITH
BOUNDARY ADJOINING STRUCTURAL ENGINEER TO SUIT NEW WORKS,
— — © - - 7. DEMOLISH EXISTING GROUND PAVERS TO
VILLA EXTENT SHOWN.
| 8. DEMOLISH EXISTING JOINERY BENCH.
p) N 9. REMOVE EXISTING TUB, EQUIPMENT AND
CUPBOARDS AND RETAIN FOR REINSTATEMENT
(CLIENT TO CONFIRM).
10. REMOVE EXISTING HOT WATER SYSTEM AND
RETAIN FOR REINSTATEMENT.
. DEMOLISH EXISTING FLOOR TO EXTENT SHOWN.
12. DEMOLISH EXISTING SANITARY FIXTURES
INCLUDING TOILETS, SHOWERS AND BASINS.
13. DEMOLISH EXISTING KITCHEN JOINERY. RETAIN
EXISTING EQUIPMENT FOR REINSTATEMENT
(CLIENT TO CONFIRM).
wu 14. DEMOLISH EXISTING COLUMN. NOTE: CONFIRM
| epoe72200mm = +g-l9 SUFFICIENT RECTIFICATION WITH STRUCTURAL
| 5 CONCRETE th"); — — | ENGINEER TO SUIT NEW WORKS.
[ZLNOTEA 6 15. DEMOLISH EXISTING AIR CONDITIONER AND WALL
= MOUNTING BRACKETS
16. DEMOLISH EXISTING TELEVISION.
I] | 17. DEMOLISH EXISTING DOWNPIPE.
tL | 18. DEMOLISH EXISTING DECKING TO EXTENT
|i 4 | SHOWN.
— 19. DEMOLISH EXISTING DECK BALUSTRADE.

 

 

 

64 (ExTG)) 20, DEMOLISH EXISTING BEDROOM JOINERY.
_ _(EXTG) 21, DEMOLISH EXISTING FLOOR TILES TO EXTENT

7 SHOWN.
| ADJOINING 22, DEMOLISH EXISTING CARPET FLOORING TO
| SHARED EXTENT SHOWN.

 

 

 

 

 

 

_— —— _—_ bb 23, DEMOLISH EXISTING ROOF SHEETING.
ADJOINING BOUNDARY | ROADWAY 24. DEMOLISH EXISTING EAVES GUTTERS.
DECK OUTLINEOVER _ 25, DEMOLISH EXISTING CEILING FITTINGS AND
SHARED ° ~~ BOUNDARY © FIXTURES.
(DEDICATED LOT 26, DEMOLISH EXISTING CEILING LINING.
ROADWAY EXCLUSIVE USE AREA) \ }

 

 

 

 

 

 

 

a

NOTE:
200) PLANS REPRESENT GENERAL DESIGN

(01 \ DEMOLITION FLOOR PLAN - GROUND DEMOLITION INTENT ONLY. FULL EXTENT OF
, SCALE 1:100 DEMOLITION REQUIRED TO SUIT PROPOSED

WORKS TO BE CONFIRMED ON SITE.

 

 

ne AMENDMENTS PROJECT DRAWING CREATED SCALE @A3
1, THIS IS ACOMPUTER GENERATED DRAWING, DONOTAMENDBYHAND.! pey DATE DESCRIPTION BY

2. THSORAMNG SHOWS ESIGN NTENT ONLY AL DIENSIONS NO FOR APPROVAL AUG 2023 1
SETOUTS ARE TO BE CHECKED ON SITE PRIOR TO ConsTRUCTION. | A |17.08.2023] ISSUE FOR BUILDING APPROVAL CB PROPOSED RESIDENTIAL ALTERATIONS AUG 2023 00
3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHINTHE DRawIGs | ® |14.01.2025] PROJECT SCOPE ADJUSTMENTS GB ADDRESS PROJECT NO. REVISION

Bele Bala
«Sonor sue msm Nee RORTOGMIRECTO 2/30 HASTINGS STREET, NOOSA HEADS QLD 4567 oe OT SROUP Poet

COPYRIGHT: | AUTHOR: GB: DRAWING WG. No, ere RPP
© GT GROUP BUILDING DESIGN. THESE DRAWINGS ARE PROTECTED BY omc an SESE

THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED | ORIGINAL SHEET SIZE: A3 420x297mm) DEMOLITION FLOOR PLAN - GROUND A051 ODETTE)

WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.

 

 

 

Page 5

LEGEND NOTE NOTES NOTE:

COL STEEL COLUMN UNLESS NOTED OTHERWISE, ALL EXISTING 1. ALL CONSTRUCTION WORK UNDERTAKEN THESE DRAWINGS ARE DESIGN CONCEPTS
BUILT WORKS ARE TO REMAIN. FOR FURTHER IS TO COMPLY WITH THE NATIONAL ONLY AND SHALL NOT BE USED IN ANY
CLARIFICATION ON EXTENT OF DEMOLITION CONSTRUCTION CODE (BCA), RELEVANT WAY FOR STRUCTURAL PURPOSES. REFER
WORKS, REFER TO PROPOSED FLOOR PLAN FOR AUSTRALIAN STANDARDS AND TO STRUCTURAL ENGINEER'S DETAILS
PROPOSED RECONFIGURATION LAYOUT, WALL APPLICABLE LOCAL AUTHORITY FOR ALL MEMBER SIZES, SPECIFICATIONS
SETOUT DIMENSIONS AND OPENING LOCATIONS. REQUIREMENTS. AND SITE SPECIFIC STRUCTURAL

2. ALL SETBACK/SETOUT DIMENSIONS ARE REQUIREMENTS.

(03 \ TO BE CHECKED AND VERIFIED ON SITE
NEU, PRIOR TO CONSTRUCTION.

no NOTE: [DEMOLITION NOTES |
ROOM DIMENSIONS
SN SHOWN ARE TO

 

 

DEMOLISH EXISTING WALLS TO EXTENT SHOWN.

DEMOLISH EXISTING DOORS AND WINDOWS.

DEMOLISH EXISTING STAIRS AND HANDRAIL.

ADJOINING FINISHED WALL FACES. DEMOLISH EXISTING CONCRETE GROUND SLAB.

| DEMOLISH EXISTING SCREEN STRUCTURES.
VILLA o— —- —_ DEMOLISH EXISTING BRACING FRAMES. NOTE:
CONFIRM SUFFICIENT RECTIFICATION WITH
BOUNDARY ADJOINING STRUCTURAL ENGINEER TO SUIT NEW WORKS,
— — © - - 7. DEMOLISH EXISTING GROUND PAVERS TO
VILLA EXTENT SHOWN.
| 8. DEMOLISH EXISTING JOINERY BENCH.

p) Cc 9. REMOVE EXISTING TUB, EQUIPMENT AND

CUPBOARDS AND RETAIN FOR REINSTATEMENT

(CLIENT TO CONFIRM).

10. DEMOLISH EXISTING HOT WATER SYSTEM AND

ASSOCIATED WORKS.

. DEMOLISH EXISTING FLOOR TO EXTENT SHOWN.

12. DEMOLISH EXISTING SANITARY FIXTURES

INCLUDING TOILETS, SHOWERS AND BASINS.

13. DEMOLISH EXISTING KITCHEN JOINERY. RETAIN
EXISTING EQUIPMENT FOR REINSTATEMENT
(CLIENT TO CONFIRM).

14. DEMOLISH EXISTING COLUMN. NOTE: CONFIRM
SUFFICIENT RECTIFICATION WITH STRUCTURAL
ENGINEER TO SUIT NEW WORKS.

15. DEMOLISH EXISTING AIR CONDITIONER AND WALL
MOUNTING BRACKETS

16. DEMOLISH EXISTING TELEVISION.

17. DEMOLISH EXISTING DOWNPIPE.

18. DEMOLISH EXISTING DECKING TO EXTENT
SHOWN.

19. DEMOLISH EXISTING DECK BALUSTRADE.

20. DEMOLISH EXISTING BEDROOM JOINERY.

DEMOLISH EXISTING FLOOR TILES TO EXTENT

DECK Fe 7 ADJOINING SHOWN.

——————— 22, DEMOLISH EXISTING CARPET FLOORING TO
a SHARED EXTENT SHOWN.
_——— - 23, DEMOLISH EXISTING ROOF SHEETING.
ADJOINING BOUNDARY. ROADWAY 24. DEMOLISH EXISTING EAVES GUTTERS.
25, DEMOLISH EXISTING CEILING FITTINGS AND
SHARED ~~ “BOUNDARY FIXTURES.

(DEDICATED LOT 26. DEMOLISH EXISTING CEILING LINING.
ROADWAY EXCLUSIVE USE AREA) . /

Parwn>

 

4
q

 

 
    

 

| NOTE 15

fo}

 

 

 

BOUNDARY

   
 

DP
(EXT.

 

 

(DEDICATED LOT
EXCLUSIVE USE AREA)

7
4
~N
\
7
mY
x

ADJOINING
VILLA

ROADWAY
@ ”
| Yew Ly Vy
YO VINGIDINING’
x

\SZNZNZNMYN My NZS
© ¢ DMM XK PIs OX OK
NOOO OO Or SO“Ks<
A\ S\N SN SSN ASN SNS NSN INNS

oO XIN NN LN IN INN IN IN NY

BOUNDARY,

7

 

Te]
|
NOTE 1

 

BOUNDARY

 

 

 

NOTE 1 NOTE 2

 

 

x

 

 

 

 

 

fF

 

 

 

 

 

 

 

 

 

 

 

 

 

a

NOTE:
200) PLANS REPRESENT GENERAL DESIGN

(01 \ DEMOLITION FLOOR PLAN - LEVEL 1 DEMOLITION INTENT ONLY. FULL EXTENT OF
, SCALE 1:100 DEMOLITION REQUIRED TO SUIT PROPOSED

WORKS TO BE CONFIRMED ON SITE.

 

 

NOTES: AMENDMENTS PROJECT “DRAWINGCREATED - [email protected]. THS OnAninG SHOH's DESIG NTENT ONLY AL DENSON np. | EY_OATE__DESORPTON ey FOR APPROVAL PROPOSED RESIDENTIAL ALTERATIONS AUG 2023 4:100

SETOUTS ARE TO BE CHECKED ON SITE PRIOR TO CONSTRUCTION. A |17.08.2023] ISSUE FOR BUILDING APPROVAL cB
PROJECT NO. REVISION

3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHIN THE DRAWINGS B | 14.01.2025] PROJECT SCOPE ADJUSTMENTS 6a ‘ADDRESS www.gtgroup.net.au
ARE TO BE REPORTED TO THE DESIGNER PRIOR TO CONSTRUCTION, © | 15.01.2025) UPDATED PROJECT SCOPE ADJUSTMENTS GB 22048 c RUG Es [lt NES
4, DONO SOA PS ORANG 2/30 HASTINGS STREET, NOOSA HEADS QLD 4567 a Re et eee

 

COPYRIGHT: [ AUTHOR: 6B DRAWING PWG, No. ae

© GT GROUP BUILDING DESIGN. THESE DRAWINGS ARE PROTECTED BY | ORIGINAL SHEET SIZE. Aa 42027 mm) DEMOLITION FLOOR PLAN - LEVEL 1 A052 (07) 3298 6938

THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED
WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.

 

Page 6

ADJOINING
VILLA

BOUNDARY

 

4
q

ADJOINING
VILLA
ROADWAY

BOUNDARY,

 

 

 

ADJOINING
SHARED
ROADWAY

ENSUITE

1965x1570mm
TILE

ATH

oP Oe

NOTH 1 NOTE2

 

1670x4970mm

TILEX 1570x860mm
TILE

EAVESJLINE O'

ADJOINING
VILLA

Wc

@— —

 

 

 

 

 

of Ios

yrs) N

ee

 

ore

[ “NOTE 1

3655x3170mm

 

 

BED 1

CARPET oo

 

  
  
 

 

 

 

 

 

 

 

BED 2

3225x2660mm
CARPET

 

“
BOUNDARY
(DEDICATED LOT
EXCLUSIVE USE AREA)

7

 

 

 

 

BOUNDARY

KN “EAVESLINEOVER
—_ —_—_—_——

‘s— =

 

 

BOUNDARY
(DEDICATED LOT

EXCLUSIVE USE AREA)

a

LEGEND

COL STEEL COLUMN

BOUNDARY

ADJOINING
SHARED
ROADWAY

(01. \ DEMOLITION FLOOR PLAN - LEVEL 2

 

NOTE

UNLESS NOTED OTHERWISE, ALL EXISTING
BUILT WORKS ARE TO REMAIN. FOR FURTHER
CLARIFICATION ON EXTENT OF DEMOLITION
WORKS, REFER TO PROPOSED FLOOR PLAN FOR
PROPOSED RECONFIGURATION LAYOUT, WALL
SETOUT DIMENSIONS AND OPENING LOCATIONS.

AS

 

NOTES

1. ALL CONSTRUCTION WORK UNDERTAKEN
|S TO COMPLY WITH THE NATIONAL
CONSTRUCTION CODE (BCA), RELEVANT
AUSTRALIAN STANDARDS AND
APPLICABLE LOCAL AUTHORITY
REQUIREMENTS.

2, ALL SETBACK/SETOUT DIMENSIONS ARE
TO BE CHECKED AND VERIFIED ON SITE
PRIOR TO CONSTRUCTION.

NOTE:

THESE DRAWINGS ARE DESIGN CONCEPTS
ONLY AND SHALL NOT BE USED IN ANY
WAY FOR STRUCTURAL PURPOSES. REFER
TO STRUCTURAL ENGINEER'S DETAILS
FOR ALL MEMBER SIZES, SPECIFICATIONS
AND SITE SPECIFIC STRUCTURAL
REQUIREMENTS.

 

 

NOTE:

ROOM DIMENSIONS
SHOWN ARE TO
FINISHED WALL FACES.

[DEMOLITION NOTES. |

DEMOLISH EXISTING WALLS TO EXTENT SHOWN.

DEMOLISH EXISTING DOORS AND WINDOWS.

DEMOLISH EXISTING STAIRS AND HANDRAIL.

DEMOLISH EXISTING CONCRETE GROUND SLAB.

DEMOLISH EXISTING SCREEN STRUCTURES.

DEMOLISH EXISTING BRACING FRAMES. NOTE:

CONFIRM SUFFICIENT RECTIFICATION WITH

STRUCTURAL ENGINEER TO SUIT NEW WORKS.

7. DEMOLISH EXISTING GROUND PAVERS TO
EXTENT SHOWN.

8. DEMOLISH EXISTING JOINERY BENCH.

9. REMOVE EXISTING TUB, EQUIPMENT AND
CUPBOARDS AND RETAIN FOR REINSTATEMENT
(CLIENT TO CONFIRM).

10. DEMOLISH EXISTING HOT WATER SYSTEM AND
ASSOCIATED WORKS.

11. DEMOLISH EXISTING FLOOR TO EXTENT SHOWN.

12. DEMOLISH EXISTING SANITARY FIXTURES
INCLUDING TOILETS, SHOWERS AND BASINS.

13. DEMOLISH EXISTING KITCHEN JOINERY. RETAIN
EXISTING EQUIPMENT FOR REINSTATEMENT
(CLIENT TO CONFIRM).

14. DEMOLISH EXISTING COLUMN. NOTE: CONFIRM
SUFFICIENT RECTIFICATION WITH STRUCTURAL
ENGINEER TO SUIT NEW WORKS.

15. DEMOLISH EXISTING AIR CONDITIONER AND WALL
MOUNTING BRACKETS.

16. DEMOLISH EXISTING TELEVISION.

17, DEMOLISH EXISTING DOWNPIPE.

18. DEMOLISH EXISTING DECKING TO EXTENT
SHOWN.

19. DEMOLISH EXISTING DECK BALUSTRADE.

20, DEMOLISH EXISTING BEDROOM JOINERY.

21, DEMOLISH EXISTING FLOOR TILES TO EXTENT
SHOWN.

22. DEMOLISH EXISTING CARPET FLOORING TO
EXTENT SHOWN.

23. DEMOLISH EXISTING ROOF SHEETING.

24. DEMOLISH EXISTING EAVES GUTTERS.

25. DEMOLISH EXISTING CEILING FITTINGS AND
FIXTURES.

26. DEMOLISH EXISTING CEILING LINING.

Parwn>

 

 

NOTE:

PLANS REPRESENT GENERAL DESIGN
DEMOLITION INTENT ONLY. FULL EXTENT OF
DEMOLITION REQUIRED TO SUIT PROPOSED

YT) SCALE 1:100

WORKS TO BE CONFIRMED ON SITE.

 

NOTES: AMENDMENTS PROJECT DRAWING CREATED SCALE @AB

 

41, THIS IS A COMPUTER GENERATED DRAWING, DO NOT AMEND BYHAND.| Rey DATE —_DESCRIPTION BY FOR APPROVAL
2. THIS DRAWING SHOWS DESIGN INTENT ONLY. ALL DIMENSIONS AND AUG 2023 11
SETOUTS ARE TO BE CHECKED ON SITE PRIOR TO ConsTRUCTION. | A |17.08.2023] ISSUE FOR BUILDING APPROVAL CB PROPOSED RESIDENTIAL ALTERATIONS 00
3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHIN THE DRAWINGS | 8 | 14.01.2025] PROJECT SCOPE ADJUSTMENTS 6a ‘ADDRESS PROJECTNO. REVISION www.gtgroup.net.au
ARE TO BE REPORTED TO THE DESIGNER PRIOR TO CONSTRUCTION. C | 15.01.2025) UPDATED PROJECT SCOPE ADJUSTMENTS GB 22048 Cc i, phe ide el
4, DONO SOA PS ORANG 2/30 HASTINGS STREET, NOOSA HEADS QLD 4567 22048 Re et eee
©.GT GROUP BULLONG DESIGN. THESE DRAWINGS ARE PROTEGTED BY [auriorce__| brawn “re SOE
THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED | ORIGINAL SHEET SIZE: A3 (420x297) DEMOLITION FLOOR PLAN - LEVEL 2 A053 Oe

WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.

 

 

Page 7

LEGEND NOTE NOTES NOTE:

COL STEEL COLUMN UNLESS NOTED OTHERWISE, ALL EXISTING 1. ALL CONSTRUCTION WORK UNDERTAKEN THESE DRAWINGS ARE DESIGN CONCEPTS
BUILT WORKS ARE TO REMAIN. FOR FURTHER IS TO COMPLY WITH THE NATIONAL ONLY AND SHALL NOT BE USED IN ANY
CLARIFICATION ON EXTENT OF DEMOLITION CONSTRUCTION CODE (BCA), RELEVANT WAY FOR STRUCTURAL PURPOSES. REFER
WORKS, REFER TO PROPOSED FLOOR PLAN FOR AUSTRALIAN STANDARDS AND TO STRUCTURAL ENGINEER'S DETAILS
PROPOSED RECONFIGURATION LAYOUT, WALL APPLICABLE LOCAL AUTHORITY FOR ALL MEMBER SIZES, SPECIFICATIONS
SETOUT DIMENSIONS AND OPENING LOCATIONS. REQUIREMENTS. AND SITE SPECIFIC STRUCTURAL

REQUIREMENTS.

 

 

Parwn>

 

4
q

 

 
    
  

 

NOTE 5 noTe1 NOTES
°COL NoTE6 COL |L\p77% id
NOTE 17 Z 4
EXTG. SANDRA A
(ExTG,) (EXTG,) Wey a

27,

BOUNDARY

  

(DEDICATED LOT
EXCLUSIVE USE AREA)

BOUNDARY,

  

wi
BI
Oo
Zz

oO
>
0
U
O°
zw
Ho
hOQ
3
|
my
|
I
BOUNDARY

 

 

 

2. ALL SETBACK/SETOUT DIMENSIONS ARE
TO BE CHECKED AND VERIFIED ON SITE
f- “
NOTE: DEMOLITION NOTES
ROOM DIMENSIONS DEMOLISH EXISTING WALLS TO EXTENT SHOWN.
MM DEMOLISH EXISTING STAIRS AND HANDRAIL.
ADJOINING FINISHED WALL FACES. DEMOLISH EXISTING CONCRETE GROUND SLAB.
|
VILLA oe - DEMOLISH EXISTING BRACING FRAMES. NOTE:
CONFIRM SUFFICIENT RECTIFICATION WITH
— — e - - 7. DEMOLISH EXISTING GROUND PAVERS TO
VILLA EXTENT SHOWN.
p-© \ 9, REMOVE EXISTING TUB, EQUIPMENT AND
CUPBOARDS AND RETAIN FOR REINSTATEMENT
10. DEMOLISH EXISTING HOT WATER SYSTEM AND
ASSOCIATED WORKS.
12. DEMOLISH EXISTING SANITARY FIXTURES
INCLUDING TOILETS, SHOWERS AND BASINS.
eh | . EXISTING EQUIPMENT FOR REINSTATEMENT
yall “oe (CLIENT TO CONFIRM).
VILLA b 7, #- | Ss
i+ -2—||S SUFFICIENT RECTIFICATION WITH STRUCTURAL
ROADWAY , fi ig rok ENGINEER TO SUIT NEW WORKS.
_ MOUNTING BRACKETS
16. DEMOLISH EXISTING TELEVISION.
FRAMING | 18. DEMOLISH EXISTING DECKING TO EXTENT
SHOWN.
-——o COL COL co. 20. DEMOLISH EXISTING BEDROOM JOINERY.
(EXTG) = __ EXT.) _(EXTG,) 21. DEMOLISH EXISTING FLOOR TILES TO EXTENT
— 2
-_ —___ _ 3. DEMOLISH EXISTING ROOF SHEETING.
ADJOINING BOUNDARY | ROADWAY 24. DEMOLISH EXISTING EAVES GUTTERS.
©

PRIOR TO CONSTRUCTION.
SHOWN ARE TO DEMOLISH EXISTING DOORS AND WINDOWS.
DEMOLISH EXISTING SCREEN STRUCTURES.
BOUNDARY ADJOINING STRUCTURAL ENGINEER TO SUIT NEW WORKS,
8. DEMOLISH EXISTING JOINERY BENCH.
(CLIENT TO CONFIRM).
. DEMOLISH EXISTING FLOOR TO EXTENT SHOWN.
ADJOINING 13. DEMOLISH EXISTING KITCHEN JOINERY. RETAIN
pu 14. DEMOLISH EXISTING COLUMN. NOTE: CONFIRM
15. DEMOLISH EXISTING AIR CONDITIONER AND WALL
5680x3310mm 17, DEMOLISH EXISTING DOWNPIPE,
I 19. DEMOLISH EXISTING DECK BALUSTRADE.
‘ ADJOINING 22 DEMOLISH EXISTING CARPET FLOORING TO
J SHARED EXTENT SHOWN.
DECK OUTLINE OVER 25. DEMOLISH EXISTING CEILING FITTINGS AND

 

 

 

SHARED O——" = SNDARY FIXTURES.

(DEDICATED LOT 26. DEMOLISH EXISTING CEILING LINING.
ROADWAY EXCLUSIVE USE AREA)

 

 

NOTE:

PLANS REPRESENT GENERAL DESIGN
(01 DEMOLITION CEILING PLAN - GROUND DEMOLITION INTENT ONLY. FULL EXTENT OF
, SCALE 1:100 DEMOLITION REQUIRED TO SUIT PROPOSED

WORKS TO BE CONFIRMED ON SITE.

 

 

NOTES: AMENDMENTS PROJECT “DRAWINGCREATED - [email protected]. THS OnAninG SHOH's DESIG NTENT ONLY AL DENSON np. | EY_OATE__DESORPTON et FOR APPROVAL PROPOSED RESIDENTIAL ALTERATIONS AUG 2023 4:100

SETOUTS ARE TO BE CHECKED ON SITE PRIOR TO CONSTRUCTION. A |17.08.2023] ISSUE FOR BUILDING APPROVAL

3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHIN THE DRAWINGS B |14.01.2025| PROJECT SCOPE ADJUSTMENTS Ge ADDRESS PROJECTNO. REVISION www.gtgroup.net.au
ARE TO BE REPORTED TO THE DESIGNER PRIOR TO CONSTRUCTION. 22048 B " . ” 7
4, DONOT SEALE TS ORANG 2/30 HASTINGS STREET, NOOSA HEADS QLD 4567 i Rr nee

COPYRIGHT: | AUTHOR: GB: DRAWING WG. No, ere RPP
© GT GROUP BUILDING DESIGN. THESE DRAWINGS ARE PROTECTED BY (OD Reece)

THE LAWS OF COPYRIGHT AND HAY NOT BE COPIED OR REPRODUCED [ORIGINAL SHEET Size: AS ezoaermm | DEMOLITION CEILING PLAN - GROUND A054

WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.

 

 

 

Page 8

ADJOINING
VILLA

BOUNDARY

 

4
q

ADJOINING
VILLA
ROADWAY

BOUNDARY,

ADJOINING
VILLA

@—_

 
  

 

 

 

A

Tian

SA
SS

OT at

NDAD
re
BS

Ss

OOO

 

 

NX
\
~

XN

x

\
NXQQOQOOQYAY

 

Z
Z
4
Ze

NN
NONN
XQ s_e
NX dye
\
SMYYYCYY

SAAS /

w*X
\

Y

TNO
YLLLTT ALS,
SLL) LLL.
SILLA L LL.

GILLES

“OIL Lp
%
LLG |

r=
ASN \
\ IN’
ane
\
Let
77

\
\

4

S\

K
NOTE NOEL
STS
ONY

YY

Sy

NS
\YX

MQ nv
“NOTE1

LULL

\
NO
SA

 

BOUNDARY

  

 

(DEDICATED LOT
EXCLUSIVE USE AREA)

7

LEGEND

COL STEEL COLUMN

BOUNDARY

NOTE

UNLESS NOTED OTHERWISE, ALL EXISTING
BUILT WORKS ARE TO REMAIN. FOR FURTHER
CLARIFICATION ON EXTENT OF DEMOLITION
WORKS, REFER TO PROPOSED FLOOR PLAN FOR
PROPOSED RECONFIGURATION LAYOUT, WALL
SETOUT DIMENSIONS AND OPENING LOCATIONS.

AS

NOTES

1. ALL CONSTRUCTION WORK UNDERTAKEN
|S TO COMPLY WITH THE NATIONAL
CONSTRUCTION CODE (BCA), RELEVANT
AUSTRALIAN STANDARDS AND
APPLICABLE LOCAL AUTHORITY
REQUIREMENTS.

2, ALL SETBACK/SETOUT DIMENSIONS ARE
TO BE CHECKED AND VERIFIED ON SITE
PRIOR TO CONSTRUCTION.

NOTE:

THESE DRAWINGS ARE DESIGN CONCEPTS
ONLY AND SHALL NOT BE USED IN ANY
WAY FOR STRUCTURAL PURPOSES. REFER
TO STRUCTURAL ENGINEER'S DETAILS
FOR ALL MEMBER SIZES, SPECIFICATIONS
AND SITE SPECIFIC STRUCTURAL
REQUIREMENTS.

 

 

NOTE:

ROOM DIMENSIONS
SHOWN ARE TO
FINISHED WALL FACES.

Parwn>

16.
17.

[DEMOLITION NOTES. |

DEMOLISH EXISTING WALLS TO EXTENT SHOWN.
DEMOLISH EXISTING DOORS AND WINDOWS.
DEMOLISH EXISTING STAIRS AND HANDRAIL.
DEMOLISH EXISTING CONCRETE GROUND SLAB.
DEMOLISH EXISTING SCREEN STRUCTURES.
DEMOLISH EXISTING BRACING FRAMES. NOTE:
CONFIRM SUFFICIENT RECTIFICATION WITH
STRUCTURAL ENGINEER TO SUIT NEW WORKS.
DEMOLISH EXISTING GROUND PAVERS TO
EXTENT SHOWN.

DEMOLISH EXISTING JOINERY BENCH.

REMOVE EXISTING TUB, EQUIPMENT AND
CUPBOARDS AND RETAIN FOR REINSTATEMENT
(CLIENT TO CONFIRM).

. DEMOLISH EXISTING HOT WATER SYSTEM AND

ASSOCIATED WORKS.

. DEMOLISH EXISTING FLOOR TO EXTENT SHOWN.
. DEMOLISH EXISTING SANITARY FIXTURES

INCLUDING TOILETS, SHOWERS AND BASINS.

. DEMOLISH EXISTING KITCHEN JOINERY. RETAIN

EXISTING EQUIPMENT FOR REINSTATEMENT
(CLIENT TO CONFIRM).

. DEMOLISH EXISTING COLUMN. NOTE: CONFIRM

SUFFICIENT RECTIFICATION WITH STRUCTURAL
ENGINEER TO SUIT NEW WORKS.

. DEMOLISH EXISTING AIR CONDITIONER AND WALL

MOUNTING BRACKETS.
DEMOLISH EXISTING TELEVISION.
DEMOLISH EXISTING DOWNPIPE.

 

 

18. DEMOLISH EXISTING DECKING TO EXTENT
SHOWN.
DEMOLISH EXISTING DECK BALUSTRADE.

DEMOLISH EXISTING BEDROOM JOINERY.

\
SN
SS

N
SS
\XN
YA
\S
A
\S
So
ae
2s.
&
\
\
\
\
\

 

NIXON
NXQOQOOYAY

19.
20.

OXON

ADJOINING
SHARED
ROADWAY

5

St YL

 

 

r

 

 

 

 

 

BOUNDARY

 

 

 

 

 

 

BOUNDARY
(DEDICATED LOT
EXCLUSIVE USE AREA)

7

ADJOINING
SHARED
ROADWAY

(01. \ DEMOLITION CEILING PLAN - LEVEL 1

 

 

NOTE:

21
22
23
24
25

26.

DEMOLISH EXISTING FLOOR TILES TO EXTENT
SHOWN.

DEMOLISH EXISTING CARPET FLOORING TO
EXTENT SHOWN.

DEMOLISH EXISTING ROOF SHEETING.
DEMOLISH EXISTING EAVES GUTTERS.
DEMOLISH EXISTING CEILING FITTINGS AND
FIXTURES.

DEMOLISH EXISTING CEILING LINING.

PLANS REPRESENT GENERAL DESIGN
DEMOLITION INTENT ONLY. FULL EXTENT OF
DEMOLITION REQUIRED TO SUIT PROPOSED

 

Yo) SCALE 1:100

WORKS TO BE CONFIRMED ON SITE.

 

NOTES:
4, THIS IS A COMPUTER GENERATED DRAWING. DO NOT AMEND BY HAND.

AMENDMENTS
REV___DATE

PROJECT DRAWING CREATED SCALE @A3

DESCRIPTION

 

 

ile cres cetacean FOR APPROVAL reuneoens
SETOUTS ARE TO BE CHECKED ON SITE PRIOR TO CONSTRUCTION. ‘A _]17.08,2023] ISSUE FOR BUILDING APPROVAL CB PROPOSED RESIDENTIAL ALTERATIONS 00

3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHINTHE DRAWINGS | 8 | 14.01.2025] PROJECT SCOPE ADJUSTMENTS SB ADDRESS PROJECT NO. REVISION www.gtgroup.net.au
ARE TO BE REPORTED TO THE DESIGNER PRIOR TO CONSTRUCTION, © | 15.01.2025) UPDATED PROJECT SCOPE ADJUSTMENTS GB 22048 c RUG Es [lt NES

4. DONOT SCALE THIS DRAWING 2/30 HASTINGS STREET, NOOSA HEADS QLD 4567 a [email protected]

{GT GROUP BULOING DESIGN. THESE ORANINGS ARE PROTECTED BY [numion cB avin OHNO CIES

THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED | ORIGINAL SHEET SIZE: A3 420x297mm) DEMOLITION CEILING PLAN - LEVEL 1 A055 ODETTE)

WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.

Page 9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  
    
   

 

 

 

 

 

 

 

 

 

ADJOINING
VILLA g¢— — —
BOUNDARY ADJOINING
_ _ @ _ -
ENSUITE NBATH VILLA
DO) 1965x1570mm —1670x4g70mm = WC
| PLASTERBOARD PLASTERBQARDs79,g6qmm 9 Po =
ASTERBOARD 8
EAVES|LINE 0} > oe
| ~ 1/282
\|2ea
~ \|ee2
zi ag3
| 4S 25
| ~<
ADJOINING 8 | .
2
VILLA
ROADWAY |
| 4 (OTE25/, |
Ge gbieg TLL |
| ZBEOA BEDE 7,
CLA, [Nore 26 ii |
“3 g/ siosteony ZN) |
— ¢ BOS 2 SOSTERBORRD 7 7, |
LO Nee LN
- | VEIL MOLLE |
IN yo
SS CCEAVESLINEOVER)— i ssts—~S~—S
ADJOINING BOUNDARY
SHARED S BOUNDARY ©
(DEDICATED LOT
ROADWAY EXCLUSIVE USE AREA)

LEGEND

COL STEEL COLUMN

BOUNDARY

ADJOINING
SHARED
ROADWAY

(01. \ DEMOLITION CEILING PLAN - LEVEL 2

 

YT) SCALE 1:100

NOTE

UNLESS NOTED OTHERWISE, ALL EXISTING
BUILT WORKS ARE TO REMAIN. FOR FURTHER
CLARIFICATION ON EXTENT OF DEMOLITION
WORKS, REFER TO PROPOSED FLOOR PLAN FOR
PROPOSED RECONFIGURATION LAYOUT, WALL
SETOUT DIMENSIONS AND OPENING LOCATIONS.

AS

NOTES

1. ALL CONSTRUCTION WORK UNDERTAKEN
|S TO COMPLY WITH THE NATIONAL
CONSTRUCTION CODE (BCA), RELEVANT
AUSTRALIAN STANDARDS AND
APPLICABLE LOCAL AUTHORITY
REQUIREMENTS.

2, ALL SETBACK/SETOUT DIMENSIONS ARE
TO BE CHECKED AND VERIFIED ON SITE
PRIOR TO CONSTRUCTION.

NOTE:

THESE DRAWINGS ARE DESIGN CONCEPTS
ONLY AND SHALL NOT BE USED IN ANY
WAY FOR STRUCTURAL PURPOSES. REFER
TO STRUCTURAL ENGINEER'S DETAILS
FOR ALL MEMBER SIZES, SPECIFICATIONS
AND SITE SPECIFIC STRUCTURAL
REQUIREMENTS.

 

 

NOTE:

ROOM DIMENSIONS
SHOWN ARE TO
FINISHED WALL FACES.

[DEMOLITION NOTES. |

DEMOLISH EXISTING WALLS TO EXTENT SHOWN.

DEMOLISH EXISTING DOORS AND WINDOWS.

DEMOLISH EXISTING STAIRS AND HANDRAIL.

DEMOLISH EXISTING CONCRETE GROUND SLAB.

DEMOLISH EXISTING SCREEN STRUCTURES.

DEMOLISH EXISTING BRACING FRAMES. NOTE:

CONFIRM SUFFICIENT RECTIFICATION WITH

STRUCTURAL ENGINEER TO SUIT NEW WORKS.

7. DEMOLISH EXISTING GROUND PAVERS TO
EXTENT SHOWN.

8. DEMOLISH EXISTING JOINERY BENCH.

9. REMOVE EXISTING TUB, EQUIPMENT AND
CUPBOARDS AND RETAIN FOR REINSTATEMENT
(CLIENT TO CONFIRM).

10. DEMOLISH EXISTING HOT WATER SYSTEM AND
ASSOCIATED WORKS.

11. DEMOLISH EXISTING FLOOR TO EXTENT SHOWN.

12. DEMOLISH EXISTING SANITARY FIXTURES
INCLUDING TOILETS, SHOWERS AND BASINS.

13. DEMOLISH EXISTING KITCHEN JOINERY. RETAIN
EXISTING EQUIPMENT FOR REINSTATEMENT
(CLIENT TO CONFIRM).

14. DEMOLISH EXISTING COLUMN. NOTE: CONFIRM
SUFFICIENT RECTIFICATION WITH STRUCTURAL
ENGINEER TO SUIT NEW WORKS.

15. DEMOLISH EXISTING AIR CONDITIONER AND WALL
MOUNTING BRACKETS.

16. DEMOLISH EXISTING TELEVISION.

17, DEMOLISH EXISTING DOWNPIPE.

18. DEMOLISH EXISTING DECKING TO EXTENT
SHOWN.

19. DEMOLISH EXISTING DECK BALUSTRADE.

20, DEMOLISH EXISTING BEDROOM JOINERY.

21, DEMOLISH EXISTING FLOOR TILES TO EXTENT
SHOWN.

22. DEMOLISH EXISTING CARPET FLOORING TO
EXTENT SHOWN.

23. DEMOLISH EXISTING ROOF SHEETING.

24. DEMOLISH EXISTING EAVES GUTTERS.

25. DEMOLISH EXISTING CEILING FITTINGS AND
FIXTURES.

26. DEMOLISH EXISTING CEILING LINING.

Parwn>

 

 

NOTE:

PLANS REPRESENT GENERAL DESIGN
DEMOLITION INTENT ONLY. FULL EXTENT OF
DEMOLITION REQUIRED TO SUIT PROPOSED
WORKS TO BE CONFIRMED ON SITE.

 

NOTES:

4, THIS IS A COMPUTER GENERATED DRAWING. DO NOT AMEND BY HAND.

2. THIS DRAWING SHOWS DESIGN INTENT ONLY. ALL DIMENSIONS AND
SETOUTS ARE TO BE CHECKED ON SITE PRIOR TO CONSTRUCTION.

3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHIN THE DRAWINGS
ARE TO BE REPORTED TO THE DESIGNER PRIOR TO CONSTRUCTION.

4. DO NOT SCALE THIS DRAWING.

COPYRIGHT:
© GT GROUP BUILDING DESIGN. THESE DRAWINGS ARE PROTECTED BY
THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED
WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.

AMENDMENTS

REV

DATE __DESCRIPTION

A |17.08,2023] ISSUE FOR BUILDING APPROVAL
B_ | 14.01.2025] PROJECT SCOPE ADJUSTMENTS
© |15.01.2025] UPDATED PROJECT SCOPE ADJUSTMENTS

ey FOR APPROVAL

2

[Auton Ge

| ORIGINAL SHEET SIZE: A3 (420x207mm]

PROJECT

PROPOSED RESIDENTIAL ALTERATIONS

ADDRESS

2/30 HASTINGS STREET, NOOSA HEADS QLD 4567

DRAWING

DEMOLITION CEILING PLAN - LEVEL 2

DRAWING CREATED SCALE @A3

 

AUG 2023 1:100
PROJECT NO. REVISION Ramer ei ear sl
22048 c GT |S} R @ lg Pp [email protected]
DWG. NO. ere RPP
3298 693
A056 (07) Ee t)

Page 10

LEGEND NOTE NOTES NOTE:

COL STEEL COLUMN UNLESS NOTED OTHERWISE, ALL EXISTING 1. ALL CONSTRUCTION WORK UNDERTAKEN THESE DRAWINGS ARE DESIGN CONCEPTS
BUILT WORKS ARE TO REMAIN. FOR FURTHER IS TO COMPLY WITH THE NATIONAL ONLY AND SHALL NOT BE USED IN ANY
CLARIFICATION ON EXTENT OF DEMOLITION CONSTRUCTION CODE (BCA), RELEVANT WAY FOR STRUCTURAL PURPOSES. REFER
WORKS, REFER TO PROPOSED FLOOR PLAN FOR AUSTRALIAN STANDARDS AND TO STRUCTURAL ENGINEER'S DETAILS
PROPOSED RECONFIGURATION LAYOUT, WALL APPLICABLE LOCAL AUTHORITY FOR ALL MEMBER SIZES, SPECIFICATIONS
SETOUT DIMENSIONS AND OPENING LOCATIONS. REQUIREMENTS. AND SITE SPECIFIC STRUCTURAL

REQUIREMENTS.

 

 

Parwn>

 

4

 

     

 

BOUNDARY
(DEDICATED LOT
EXCLUSIVE USE AREA)

ADJOINING
VILLA
ROADWAY

BOUNDARY,

7

BOUNDARY

 

 

 

TO BE CHECKED AND VERIFIED ON SITE
MN ROOM DIMENSIONS DEMOLISH EXISTING WALLS TO EXTENT SHOWN.
DEMOLISH EXISTING CONCRETE GROUND SLAB.
VILLA ! ¢— - —
CONFIRM SUFFICIENT RECTIFICATION WITH
VILLA EXTENT SHOWN.
CUPBOARDS AND RETAIN FOR REINSTATEMENT
ASSOCIATED WORKS.
INCLUDING TOILETS, SHOWERS AND BASINS.
(CLIENT TO CONFIRM).
ENGINEER TO SUIT NEW WORKS.
16. DEMOLISH EXISTING TELEVISION.
SHOWN.
21, DEMOLISH EXISTING FLOOR TILES TO EXTENT
ADJOINING BOUNDARY ROADWAY 24. DEMOLISH EXISTING EAVES GUTTERS.

2. ALL SETBACK/SETOUT DIMENSIONS ARE
PRIOR TO CONSTRUCTION.
f- “
NOTE: DEMOLITION NOTES
SHOWN ARE TO DEMOLISH EXISTING DOORS AND WINDOWS.
DEMOLISH EXISTING STAIRS AND HANDRAIL.
ADJOINING FINISHED WALL FACES.
DEMOLISH EXISTING SCREEN STRUCTURES.
DEMOLISH EXISTING BRACING FRAMES. NOTE:
BOUNDARY ADJOINING STRUCTURAL ENGINEER TO SUIT NEW WORKS,
— — © - - 7. DEMOLISH EXISTING GROUND PAVERS TO
8. DEMOLISH EXISTING JOINERY BENCH.
p) N 9. REMOVE EXISTING TUB, EQUIPMENT AND
(CLIENT TO CONFIRM).
10. DEMOLISH EXISTING HOT WATER SYSTEM AND
. DEMOLISH EXISTING FLOOR TO EXTENT SHOWN.
12. DEMOLISH EXISTING SANITARY FIXTURES
13. DEMOLISH EXISTING KITCHEN JOINERY. RETAIN
EXISTING EQUIPMENT FOR REINSTATEMENT
14. DEMOLISH EXISTING COLUMN. NOTE: CONFIRM
SUFFICIENT RECTIFICATION WITH STRUCTURAL
15. DEMOLISH EXISTING AIR CONDITIONER AND WALL
MOUNTING BRACKETS
17. DEMOLISH EXISTING DOWNPIPE.
18. DEMOLISH EXISTING DECKING TO EXTENT
19. DEMOLISH EXISTING DECK BALUSTRADE.
20. DEMOLISH EXISTING BEDROOM JOINERY.
ADJOINING oN
a 22. DEMOLISH EXISTING CARPET FLOORING TO
EXTENT SHOWN.
SHARED 23. DEMOLISH EXISTING ROOF SHEETING.
25. DEMOLISH EXISTING CEILING FITTINGS AND
SHARED ~~ “BOUNDARY _ FIXTURES.

 

 

 

(DEDICATED LOT 26. DEMOLISH EXISTING CEILING LINING.
ROADWAY EXCLUSIVE USE AREA) 27. DEMOLISH EXISTING CEILING AND FRAMING TO
EXTENT SHOWN TO SUIT PROPOSED WORKS,

 

 

NOTE:

PLANS REPRESENT GENERAL DESIGN
(01 DEMOLITION ROOF CAVITY PLAN DEMOLITION INTENT ONLY. FULL EXTENT OF
, SCALE 1:100 DEMOLITION REQUIRED TO SUIT PROPOSED

WORKS TO BE CONFIRMED ON SITE.

 

 

NOTES: AMENDMENTS PROJECT DRAWING CREATED [email protected] asscareceenzome ouaeorr ie | ey oe seer «|| FORAPPROVAL | cco RESIDENTIAL ALTERATIONS Rus 2028° 100
SETOUTS ARE TO BE CHECKED ON SITE PRIOR TO.CONSTRUCTION. | A | 17.08.2023] ISSUE FOR BUILDING APPROVAL GB 5

2. ANY DISCREPANCIES OR OMISSIONS FOUND WITHIN THE ORAWNNGs | & |14.01.2025| PROJECT SCOPE ADJUSTMENTS cB ADDRESS PROJECT NO. REVISION

Bele Bala
«Sonor sue msm Nee RORTOGMIRECTO 2/30 HASTINGS STREET, NOOSA HEADS QLD 4567 on OT SROUP Poet

COPYRIGHT: | AUTHOR: GB: DRAWING WG. No, ere RPP
© GT GROUP BUILDING DESIGN. THESE DRAWINGS ARE PROTECTED BY

THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED | ORIGINAL SHEET SIZE: A3 420x297mm) DEMOLITION ROOF CAVITY PLAN A057 ODETTE)

WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.

 

 

 

Page 11

NOTE NOTES NOTE:

UNLESS NOTED OTHERWISE, ALL EXISTING 1. ALL CONSTRUCTION WORK UNDERTAKEN THESE DRAWINGS ARE DESIGN CONCEPTS
BUILT WORKS ARE TO REMAIN. FOR FURTHER IS TO COMPLY WITH THE NATIONAL ONLY AND SHALL NOT BE USED IN ANY
CLARIFICATION ON EXTENT OF DEMOLITION CONSTRUCTION CODE (BCA), RELEVANT WAY FOR STRUCTURAL PURPOSES. REFER
WORKS, REFER TO PROPOSED FLOOR PLAN FOR AUSTRALIAN STANDARDS AND TO STRUCTURAL ENGINEER'S DETAILS
PROPOSED RECONFIGURATION LAYOUT, WALL APPLICABLE LOCAL AUTHORITY FOR ALL MEMBER SIZES, SPECIFICATIONS
SETOUT DIMENSIONS AND OPENING LOCATIONS. REQUIREMENTS. AND SITE SPECIFIC STRUCTURAL

2. ALL SETBACK/SETOUT DIMENSIONS ARE REQUIREMENTS.

(03 \ (BY TO BE CHECKED AND VERIFIED ON SITE
(2205 4 PRIOR TO CONSTRUCTION.

 

 

 

  
 
     
 

 

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 

 

 

 

 

  

 

 

 

NOTE:
ROOM DIMENSIONS
N\ SHOWN ARE TO
ADJOINING ADJOINING FINISHED WALL FACES.
VILLA VILLA oq -
ROADWAY
- lig __ BOUNDARY _ ADJOINING LEGEND
VILLA ——_———
| AW AWNING WINDOW
-O \ COL STEEL COLUMN
CT COOKTOP
| I WC = DHW DOUBLE HUNG WINDOW
1725x900mm oe DP  DOWNPIPE
| TILE Bow DRY CLOTHES DRYER
0615 SGW geo FW FLOOR WASTE
. oa EXTG. p38 e a DW DISHWASHER
a7 So z DP *COL wd) HEE ag s rm FGW FIXED GLASS WINDOW
| "| al (EXTG.) /(EXTG.) ew WS 2 Ou £9 S HB — HAND BASIN
3300 8) 4 oy Se eae a 2 (3300 HWU HOT WATER UNIT
| y 3 470] B Foo LUBII| °7] N LVW LOUVRE WINDOW
e : ene pee s = NOTE: ALTERATIONS TO EXISTING OV OVEN
L Cr + NTRY ; 2 STRUCTURAL FRAMING TO SUIT P PANTRY
3 @ARPORT: 200x1075mm- era ADJUSTED STAIR CONFIGURATION TO REF REFRIGERATOR
(04 >! a I {\sso0x32domm)! Il > 5 4 (02) STRUCTURAL ENGINEER'S DETAILS SGD SLIDING GLASS DOOR
(2203 5 “\conorerel" COL "7797 ScD = * (22027 SGW_ SLIDING GLASS WINDOW
| rhe -as4} \j (EXTG) 25 zZ SHR SHOWER
iL ‘Il g 3 SWP SANITARY WASTE PIPE
s ri ea 2l= gs WC TOILET
2 & ¢ 72 & WM — WASHING MACHINE
WP WASTE PIPE
- ——o COL 910
s EXT) COL °
° (EXTG) 7 >
| ADJOINING
| / SHARED
ADJOINING BOUNDARY | ROADWAY
SHARED o—— —“FounpaRyY SC

ROADWAY (DEDICATED LOT N\

EXCLUSIVE USE AREA)
CRITICAL NOTE: LIFT SHAFT OPENING AND

 

% 3210 70 2100 ooo EXTENTS CRITICAL TO SUIT LIFT SUPPLIER'S
Ht Het +$—<Ht REQUIREMENTS, BUILDER TO CONFIRM SHAFT

OPENING ON SITE AND COORDINATE WITH LIFT
SUPPLIER TO ENSURE SUFFICIENT OPENING.

= CRITICAL NOTE: PARTITION WALLS SHOWN ARE BASED ON 70mm WIDE STUD FOR
(or 4 (38 APPROVAL PURPOSES ONLY. REFER TO STRUCTURAL ENGINEER'S DETAILS FOR ALL
Kaz) SKas007 FRAMING SIZING AND STRUCTURAL REQUIREMENTS THROUGHOUT PROPOSED
WORKS. WHERE 90mm STUD FRAMES ARE REQUIRED TO SUIT PROPOSED
STRUCTURE, BUILDER TO MAINTAIN EXTERNAL BUILDING FOOTPRINT AND ADJUST
(01 PROPOS ED FLOOR PLAN - G ROU ND ROOM SIZES ACCORDINGLY ON INTERNAL SIDE, ENSURING MINIMUM INTERNAL
7 SCALE 1-100 CIRCULATION WIDTHS ARE MAINTAINED (WHERE REQUIRED). ALL DIMENSIONS
Yo) SHOWN ARE FOR APPROVAL PURPOSES ONLY, STRUCTURAL LAYOUT TO BE
CONFIRMED ON SITE BY PROJECT ENGINEER & BUILDER PRIOR TO CONSTRUCTION.

 

 

 

NOTES: AMENDMENTS PROJECT DRAWING CREATED SCALE @A3
1, THIS IS A COMPUTER GENERATED DRAWING. DONOT AMEND BYHAND.! Rey DATE DESCRIPTION BY FOR APPROVAL
2. THIS DRAWING SHOWS DESIGN INTENT ONLY. ALL DIMENSIONS AND AUG 2023 14
SETOUTS ARE TO BE CHECKED ON SITE PRIOR TO.CONSTRUCTION. | A | 17.08.2023] ISSUE FOR BUILDING APPROVAL cB PROPOSED RESIDENTIAL ALTERATIONS AUG 202300 11000
3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHIN THE DRAWINGS | 8 |13.09.2023] UPDATED ISSUE FOR BUILDING APPROVAL cB ‘ADDRESS PROJECT NO. REVISION Pe lente
ARE TO BE REPORTED TO THE DESIGNER PRIOR TO CONSTRUCTION, © | 14.01.2025) PROJECT SCOPE ADJUSTMENTS GB 22048 D RUG Es [lt NES
4, DO NOT SCALE THIS DRAWING. D_ 15.01.2025 | UPDATED PROJECT SCOPE ADJUSTMENTS GB 2/130 HASTINGS STREET, NOOSA HEADS QLD 4567 [email protected]
eae unicorn yee sce corer [Sn mama | OM a0 eee
Fe Lace GTN MOMMY NOS Co oR REPRODLCE [cmna SETSeE KiaHaeTe! | PROPOSED FLOOR PLAN - GROUND A100 CDTEDERE

 

WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.

Page 12

ADJOINING
VILLA
ROADWAY

Vv

ADJOINING
VILLA

BOUNDARY

 

4
q

70
(0 2295

4

ADJOINING

Loan)

VILLA

NOTE

UNLESS NOTED OTHERWISE, ALL EXISTING
BUILT WORKS ARE TO REMAIN. FOR FURTHER
CLARIFICATION ON EXTENT OF DEMOLITION
WORKS, REFER TO PROPOSED FLOOR PLAN FOR
PROPOSED RECONFIGURATION LAYOUT, WALL
SETOUT DIMENSIONS AND OPENING LOCATIONS.

@— —

 

 

| "PANTRY *

1950x1360mm
TIMBER

BOUNDARY,

N
70 70 gq 70 b 79
1D 1388, pe 174g

 
 
 
  
 

 

BOUNDARY
70

(DEDICATED LOT
EXCLUSIVE USE AREA)

  

©

715

NOTES

1. ALL CONSTRUCTION WORK UNDERTAKEN
|S TO COMPLY WITH THE NATIONAL
CONSTRUCTION CODE (BCA), RELEVANT

NOTE:

THESE DRAWINGS ARE DESIGN CONCEPTS
ONLY AND SHALL NOT BE USED IN ANY

WAY FOR STRUCTURAL PURPOSES. REFER

TO STRUCTURAL ENGINEER'S DETAILS

AUSTRALIAN STANDARDS AND
APPLICABLE LOCAL AUTHORITY FOR ALL MEMBER SIZES, SPECIFICATIONS
REQUIREMENTS. AND SITE SPECIFIC STRUCTURAL

2. ALL SETBACK/SETOUT DIMENSIONS ARE REQUIREMENTS.

TO BE CHECKED AND VERIFIED ON SITE
PRIOR TO CONSTRUCTION.

 

NOTE:

ROOM DIMENSIONS
SHOWN ARE TO
FINISHED WALL FACES.

AS

LEGEND

AW — AWNING WINDOW
COL STEEL COLUMN

CT COOKTOP

DHW DOUBLE HUNG WINDOW
DP = DOWNPIPE

DRY CLOTHES DRYER

FW FLOOR WASTE

DW DISHWASHER

FGW FIXED GLASS WINDOW
HB HAND BASIN

LVW LOUVRE WINDOW

OV OVEN

P PANTRY

7450, 920 60020

  

04521 FGW

600mm WIDE 'HEKA HOOD' OR APPROVED
EQUIVALENT WINDOW AWNINGS x2. BUILDER
TO CONFIRM SPECIFIC AWNING DETAILS WITH
CLIENT PRIOR TO CONSTRUCTION

REF

SGD
sSGW
SHR

REFRIGERATOR

SLIDING GLASS DOOR
SLIDING GLASS WINDOW
SHOWER

3295

 

 

2120
70
yb
al

ROOF OVER

7

ADJOINING
SHARED
ROADWAY

 

 

 
 
 
 

DECK

4895x2110mm
— TIMBER

  

BOUNDARY.

  
 

Zz

BOUNDARY

(DEDICATED LOT

EXCLUSIVE USE AREA)

4845 ROOF OVER

t
LX

 
   
     
          

SS

OVER

R

COL

, 1740

O©

(01. \ PROPOSED FLOOR PLAN - LEVEL 1

BOUNDARY
1785
®

2115 DHW
1520

7

“ ADJOINING
YY SHARED

ROADWAY

A

CRITICAL NOTE: LIFT SHAFT OPENING AND
EXTENTS CRITICAL TO SUIT LIFT SUPPLIER'S
Ht REQUIREMENTS. BUILDER TO CONFIRM SHAFT
OPENING ON SITE AND COORDINATE WITH LIFT
SUPPLIER TO ENSURE SUFFICIENT OPENING.

70

 

Yo) SCALE 1:100

swP
we
WM
wP

SANITARY WASTE PIPE
TOILET

WASHING MACHINE
WASTE PIPE

AN

CRITICAL NOTE: PARTITION WALLS SHOWN ARE BASED ON 70mm WIDE STUD FOR
APPROVAL PURPOSES ONLY. REFER TO STRUCTURAL ENGINEER'S DETAILS FOR ALL
FRAMING SIZING AND STRUCTURAL REQUIREMENTS THROUGHOUT PROPOSED
WORKS. WHERE 90mm STUD FRAMES ARE REQUIRED TO SUIT PROPOSED
STRUCTURE, BUILDER TO MAINTAIN EXTERNAL BUILDING FOOTPRINT AND ADJUST
ROOM SIZES ACCORDINGLY ON INTERNAL SIDE, ENSURING MINIMUM INTERNAL
CIRCULATION WIDTHS ARE MAINTAINED (WHERE REQUIRED). ALL DIMENSIONS
SHOWN ARE FOR APPROVAL PURPOSES ONLY, STRUCTURAL LAYOUT TO BE
CONFIRMED ON SITE BY PROJECT ENGINEER & BUILDER PRIOR TO CONSTRUCTION.

 

NOTES:

4, THIS IS A COMPUTER GENERATED DRAWING. DO NOT AMEND BY HAND.

2. THIS DRAWING SHOWS DESIGN INTENT ONLY. ALL DIMENSIONS AND
SETOUTS ARE TO BE CHECKED ON SITE PRIOR TO CONSTRUCTION.

3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHIN THE DRAWINGS
ARE TO BE REPORTED TO THE DESIGNER PRIOR TO CONSTRUCTION.

4. DO NOT SCALE THIS DRAWING.

COPYRIGHT:
© GT GROUP BUILDING DESIGN. THESE DRAWINGS ARE PROTECTED BY
THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED
WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.

AMENDMENTS
REV___DATE

DESCRIPTION

 

A |17.08,2023] ISSUE FOR BUILDING APPROVAL
B_ | 14.01.2025] PROJECT SCOPE ADJUSTMENTS
© |15.01.2025] UPDATED PROJECT SCOPE ADJUSTMENTS

D

FOR APPROVAL

PROJECT

PROPOSED RESIDENTIAL ALTERATIONS

ADDRESS

2/30 HASTINGS STREET, NOOSA HEADS QLD 4567

DRAWING

PROPOSED FLOOR PLAN - LEVEL 1

[Auton Ge
| ORIGINAL SHEET SIZE: A3 [420x297mm]

DRAWING CREATED SCALE @A3

 

AUG 2023 1:100
PROJECT NO. REVISION Ramer ei ear sl
22048 c GT |S} R @ lg Pp [email protected]
DWG. NO. ere RPP
3298 693
A 01 (07) Ee t)

 

Page 13

NOTE

 

 

 

   
  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

    
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES NOTE:

 

 

 

UNLESS NOTED OTHERWISE, ALL EXISTING 1. ALL CONSTRUCTION WORK UNDERTAKEN THESE DRAWINGS ARE DESIGN CONCEPTS
BUILT WORKS ARE TO REMAIN. FOR FURTHER IS TO COMPLY WITH THE NATIONAL ONLY AND SHALL NOT BE USED IN ANY
CLARIFICATION ON EXTENT OF DEMOLITION CONSTRUCTION CODE (BCA), RELEVANT WAY FOR STRUCTURAL PURPOSES. REFER
WORKS, REFER TO PROPOSED FLOOR PLAN FOR AUSTRALIAN STANDARDS AND TO STRUCTURAL ENGINEER'S DETAILS
PROPOSED RECONFIGURATION LAYOUT, WALL APPLICABLE LOCAL AUTHORITY FOR ALL MEMBER SIZES, SPECIFICATIONS
SETOUT DIMENSIONS AND OPENING LOCATIONS. REQUIREMENTS. AND SITE SPECIFIC STRUCTURAL
2. ALL SETBACK/SETOUT DIMENSIONS ARE REQUIREMENTS.
(oe 8» TO BE CHECKED AND VERIFIED ON SITE
wn) 4 ia PRIOR TO CONSTRUCTION.
v
NOTE:
q ROOM DIMENSIONS
ADJOINING ADJOINING FINISHED WALL FACES.
|
VILLA VILLA ° _
ROADWAY
. BOUNDARY ADJOINING LEGEND
_ _ @ -
ENSUI WC VILLA —
AW AWNING WINDOW
2265x157 157061371
DO Soe 5 al COL STEEL COLUMN
70 (2205 194308, 79 p80 70 174gP 78 — = CT — COOKTOP
| | Ht Ht it —$_ Ht Ht 5 DHW DOUBLE HUNG WINDOW
% DP DOWNPIPE
EAVES LINE 0) o&
— | -EXISING Sp? Baw DRY CLOTHES DRYER
| [ J Ct ED 5 ES FW FLOOR WASTE
a oa | _ aos 2 a DW DISHWASHER
a = DI ce y|H8 ae Ci l| aa rm FGW_ FIXED GLASS WINDOW
| & S| yrs) F F BO) ZA 2g = HB HAND BASIN
\ 4300 8 Z at, wpe S a 8 \ 4300 LVW_ LOUVRE WINDOW
3 | ee 2 _ oN OV OVEN
eae a 4 = = 2 P PANTRY
C errr D g wo REF REFRIGERATOR
ELLA a S SGD SLIDING GLASS DOOR
(04 >! I | —— | ‘ | & = 2 4 (02 SGW SLIDING GLASS WINDOW
2203) | 8 a \a202/ SHR SHOWER
b BED 1 BED 2 8 2 SWP SANITARY WASTE PIPE
| s z 3 WC TOILET
8 =
| 3655x3170mm 3225x2660mm 3 a 3 WM WASHING MACHINE
—— G CARPET (—~ CARPET 8 & WP — WASTE PIPE
| JRL 7.535] <5 '_ LOFT ACCESS =
~ © / LADDER OVER
ae | = y 4
us, 4 ADJOINING
S HII) JU AU) FL
@ N i | EAVES LINE OVER SHARED
g Ren |e 1 -
ADJOINING & Ny) | BOUNDARY, ROADWAY
> = = =—
SHARED ~ DP BOUNDARY |_ INSULATED PANEL ROOF OVER
ROADWAY exe tee Use ene a) EXISTING DECK TO STRUCTURAL
ENGINEER'S OETA CRITICAL NOTE: LIFT SHAFT OPENING AND
EXTENTS CRITICAL TO SUIT LIFT SUPPLIER'S
4845 ROOF 174
# # oy REQUIREMENTS. BUILDER TO CONFIRM SHAFT
OPENING ON SITE AND COORDINATE WITH LIFT
SUPPLIER TO ENSURE SUFFICIENT OPENING.
> CRITICAL NOTE: PARTITION WALLS SHOWN ARE BASED ON 70mm WIDE STUD FOR
(or 4 (BY APPROVAL PURPOSES ONLY. REFER TO STRUCTURAL ENGINEER'S DETAILS FOR ALL
Kan) SK a0 FRAMING SIZING AND STRUCTURAL REQUIREMENTS THROUGHOUT PROPOSED
WORKS. WHERE 90mm STUD FRAMES ARE REQUIRED TO SUIT PROPOSED
PROPOSED FLOOR PLAN - LEVEL 2 STRUCTURE, BUILDER TO MAINTAIN EXTERNAL BUILDING FOOTPRINT AND ADJUST
01 - ROOM SIZES ACCORDINGLY ON INTERNAL SIDE, ENSURING MINIMUM INTERNAL
7 SCALE 1-100 CIRCULATION WIDTHS ARE MAINTAINED (WHERE REQUIRED). ALL DIMENSIONS
SHOWN ARE FOR APPROVAL PURPOSES ONLY, STRUCTURAL LAYOUT TO BE
CONFIRMED ON SITE BY PROJECT ENGINEER & BUILDER PRIOR TO CONSTRUCTION.
wores: ‘AMENDMENTS Rover TRUCE “SHES
41, THIS IS A COMPUTER GENERATED DRAWING, DO NOT AMEND BY HAND.| rey DATE DESCRIPTION BY Fi R APPR VAL "
> Terouts ANE 10 86 CHECKED ON SITE PRIOR TOCONSTHUCTION. | A ]17.08.2023] ISSUE FOR BUILDING APPROVAL CB 0 0 PROPOSED RESIDENTIAL ALTERATIONS AUG 202300 1:00,
® tke tosereronep rome neoonge suonTocaerucion | © |18012028| UPDATED PROJECT SCOPE ADJUSTMENTS 8 poones 72048 .C CO or aoe
4. BOWoT SCALE TS DRAWING 2130 HASTINGS STREET, NOOSA HEADS QLD 4567 a GT |S} R @ lg Pp meric ues
COPYRIGHT: TamnoR Ga | rans DWG. NO, OYTO aY 7)
THE LAWS OF COBVRIGHT AND HAY NOT BE CODIED OR REPRODUCED. | ORIGINAL SHEET SIZE: A3 (420x297) PROPOSED FLOOR PLAN - LEVEL 2 A102 Oe

WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.

 

 

Page 14

NOTE NOTES NOTE:

UNLESS NOTED OTHERWISE, ALL EXISTING 1. ALL CONSTRUCTION WORK UNDERTAKEN THESE DRAWINGS ARE DESIGN CONCEPTS
BUILT WORKS ARE TO REMAIN. FOR FURTHER IS TO COMPLY WITH THE NATIONAL ONLY AND SHALL NOT BE USED IN ANY
CLARIFICATION ON EXTENT OF DEMOLITION CONSTRUCTION CODE (BCA), RELEVANT WAY FOR STRUCTURAL PURPOSES. REFER
WORKS, REFER TO PROPOSED FLOOR PLAN FOR AUSTRALIAN STANDARDS AND TO STRUCTURAL ENGINEER'S DETAILS
PROPOSED RECONFIGURATION LAYOUT, WALL APPLICABLE LOCAL AUTHORITY FOR ALL MEMBER SIZES, SPECIFICATIONS
SETOUT DIMENSIONS AND OPENING LOCATIONS. REQUIREMENTS. AND SITE SPECIFIC STRUCTURAL

2. ALL SETBACK/SETOUT DIMENSIONS ARE REQUIREMENTS.

 

(03 \ (BY TO BE CHECKED AND VERIFIED ON SITE
(2205 4 PRIOR TO CONSTRUCTION.

 

 

 

 
 
   
 

 

 
 
  

 

 

 

 

 

 

 

v
NOTE:
ROOM DIMENSIONS
N\ SHOWN ARE TO
ADJOINING ADJOINING FINISHED WALL FACES.
|
VILLA VILLA oq -
ROADWAY
- wg — BOUNDARY ADJOINING LEGEND
VILLA ———
AW AWNING WINDOW
DO ; v9 ; Lao COL STEEL COLUMN
7 7 7 —
2875 7 880 1748 CT COOKTOP
| | He or Qe ate Ht = DHW DOUBLE HUNG WINDOW
EAVES LINE 0) oe DP DOWNPIPE
TT Tee Bow DRY CLOTHES DRYER
48075 DHW aus FW FLOOR WASTE
a 2 | S538 2 a DW DISHWASHER
i» > 883 » FGW FIXED GLASS WINDOW
| 3 Al £8 3 HB HAND BASIN
\ 4300 8 Z | | a 8 \ 4300 LVW_ LOUVRE WINDOW
3 \ OV OVEN
| = = | e P PANTRY
g 8 REF REFRIGERATOR
23 ca SGD SLIDING GLASS DOOR
(04) >! | | Z Zz | > 4 (02 SGW SLIDING GLASS WINDOW
(2037 | 5 5 | < (22027) SHR SHOWER
| b 3 3 oS SWP SANITARY WASTE PIPE
3 2 2 3 8 we TOILET
| 3 Z| WM — WASHING MACHINE
——o G | | WP WASTE PIPE
- ——6
® | 18075 DHW | 7 ®
ADJOINING
>, EAVES LINE OVER SHARED
\s— — ee
ADJOINING BOUNDARY ROADWAY
SHARED S ~~ “BOUNDARY © N\
(DEDICATED LOT
ROADWAY EXCLUSIVE USE AREA)
0 0 CRITICAL NOTE: LIFT SHAFT OPENING AND
7885 760 9875 EXTENTS CRITICAL TO SUIT LIFT SUPPLIER'S
He t—+ He REQUIREMENTS. BUILDER TO CONFIRM SHAFT
OPENING ON SITE AND COORDINATE WITH LIFT
SUPPLIER TO ENSURE SUFFICIENT OPENING.

FRAMING SIZING AND STRUCTURAL REQUIREMENTS THROUGHOUT PROPOSED
WORKS. WHERE 90mm STUD FRAMES ARE REQUIRED TO SUIT PROPOSED
PROPOS ED FLOOR PLAN - LO FT STRUCTURE, BUILDER TO MAINTAIN EXTERNAL BUILDING FOOTPRINT AND ADJUST
01 ROOM SIZES ACCORDINGLY ON INTERNAL SIDE, ENSURING MINIMUM INTERNAL
ay, SCALE 1-100 CIRCULATION WIDTHS ARE MAINTAINED (WHERE REQUIRED). ALL DIMENSIONS

SHOWN ARE FOR APPROVAL PURPOSES ONLY, STRUCTURAL LAYOUT TO BE
CONFIRMED ON SITE BY PROJECT ENGINEER & BUILDER PRIOR TO CONSTRUCTION.

> CRITICAL NOTE: PARTITION WALLS SHOWN ARE BASED ON 70mm WIDE STUD FOR
4 (B APPROVAL PURPOSES ONLY. REFER TO STRUCTURAL ENGINEER'S DETAILS FOR ALL

 

 

 

NOTES: AMENDMENTS PROJECT DRAWING CREATED SCALE @AS

1, THIS IS A COMPUTER GENERATED DRAWING. DONOT AMEND BYHAND.! Rey DATE DESCRIPTION BY FOR APPROVAL

2. THIS DRAWING SHOWS DESIGN INTENT ONLY. ALL DIMENSIONS AND AUG 2023 11
SETOUTS ARE TO BE CHECKED ON SITE PRIOR TOCoNSTRUCTION | A ]17.08.2023] ISSUE FOR BUILDING APPROVAL GB PROPOSED RESIDENTIAL ALTERATIONS AUG 2023 00

3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHIN THE DRAWINGS | 8 | 14.01.2025] PROJECT SCOPE ADJUSTMENTS cB ‘ADDRESS PROJECT NO. REVISION Pe lente
[ARE TO BE REPORTED TO THE DESIGNER PRIOR TO CONSTRUCTION 22048 B dele hh elds

4, DONO SOA PS ORANG 2/30 HASTINGS STREET, NOOSA HEADS QLD 4567 208 Re et eee

COPYRIGHT: [AUTHOR cB SS«*'CRAWINGG DW. No. Sees

© GT GROUP BUILDING DESIGN. THESE DRAWINGS ARE PROTECTED BY

THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED | ORIGINAL SHEET SIZE: A3 (420x297mm] PROPOSED FLOOR PLAN - LOFT M 03

WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.

(07) 3298 6938

 

 

Page 15

ADJOINING
VILLA

BOUNDARY

 

ADJOINING
VILLA
ROADWAY

 

 

ADJOINING
SHARED

4
q

BOUNDARY,

 

ROADWAY

ADJOINING
VILLA

~ BOUNDARY

 

~~ “BOUNDARY ©

(DEDICATED LOT
EXCLUSIVE USE AREA)

    
   
  
   

BOUNDARY
(DEDICATED LOT
EXCLUSIVE USE AREA)

7

7

 

(01. \ PROPOSED FLOOR PLAN - ROOF

 

Yo) SCALE 1:100

NOTE

UNLESS NOTED OTHERWISE, ALL EXISTING
BUILT WORKS ARE TO REMAIN. FOR FURTHER
CLARIFICATION ON EXTENT OF DEMOLITION

NOTES

1. ALL CONSTRUCTION WORK UNDERTAKEN
|S TO COMPLY WITH THE NATIONAL
CONSTRUCTION CODE (BCA), RELEVANT

NOTE:

THESE DRAWINGS ARE DESIGN CONCEPTS
ONLY AND SHALL NOT BE USED IN ANY
WAY FOR STRUCTURAL PURPOSES. REFER

TO STRUCTURAL ENGINEER'S DETAILS

WORKS, REFER TO PROPOSED FLOOR PLAN FOR AUSTRALIAN STANDARDS AND
PROPOSED RECONFIGURATION LAYOUT, WALL APPLICABLE LOCAL AUTHORITY FOR ALL MEMBER SIZES, SPECIFICATIONS
SETOUT DIMENSIONS AND OPENING LOCATIONS. REQUIREMENTS. AND SITE SPECIFIC STRUCTURAL

ROOF MOUNTED SOLAR
PANEL SYSTEM AS SPECIFIED
TO NORTH FACING SIDE OF
EXISTING ROOF

BOUNDARY

ADJOINING
SHARED
ROADWAY

2, ALL SETBACK/SETOUT DIMENSIONS ARE
TO BE CHECKED AND VERIFIED ON SITE
PRIOR TO CONSTRUCTION.

AN

 

REQUIREMENTS.

NOTE:

ROOM DIMENSIONS
SHOWN ARE TO
FINISHED WALL FACES.

LEGEND

AW — AWNING WINDOW

COL STEEL COLUMN

CT COOKTOP

DHW DOUBLE HUNG WINDOW
DP = DOWNPIPE

DRY CLOTHES DRYER

FW FLOOR WASTE

DW DISHWASHER

FGW FIXED GLASS WINDOW
HB HAND BASIN

LVW LOUVRE WINDOW

OV OVEN

P PANTRY

REF REFRIGERATOR

SGD SLIDING GLASS DOOR
SGW SLIDING GLASS WINDOW
SHR SHOWER

SWP SANITARY WASTE PIPE
wc TOILET

WM WASHING MACHINE

CRITICAL NOTE: PARTITION WALLS SHOWN ARE BASED ON 70mm WIDE STUD FOR
APPROVAL PURPOSES ONLY. REFER TO STRUCTURAL ENGINEER'S DETAILS FOR ALL
FRAMING SIZING AND STRUCTURAL REQUIREMENTS THROUGHOUT PROPOSED
WORKS. WHERE 90mm STUD FRAMES ARE REQUIRED TO SUIT PROPOSED
STRUCTURE, BUILDER TO MAINTAIN EXTERNAL BUILDING FOOTPRINT AND ADJUST
ROOM SIZES ACCORDINGLY ON INTERNAL SIDE, ENSURING MINIMUM INTERNAL
CIRCULATION WIDTHS ARE MAINTAINED (WHERE REQUIRED). ALL DIMENSIONS
SHOWN ARE FOR APPROVAL PURPOSES ONLY, STRUCTURAL LAYOUT TO BE
CONFIRMED ON SITE BY PROJECT ENGINEER & BUILDER PRIOR TO CONSTRUCTION.

 

NOTES:

4, THIS IS A COMPUTER GENERATED DRAWING. DO NOT AMEND BY HAND.

2. THIS DRAWING SHOWS DESIGN INTENT ONLY. ALL DIMENSIONS AND
SETOUTS ARE TO BE CHECKED ON SITE PRIOR TO CONSTRUCTION.

AMENDMENTS

REV

A |17.08,2023] ISSUE FOR BUILDING APPROVAL

DATE __DESCRIPTION

ee FOR APPROVAL

PROJECT

PROPOSED RESIDENTIAL ALTERATIONS

DRAWING CREATED SCALE @A3

AUG 2023 1:100

PROJECT NO, REVISION
22048 B

DWG, NO,

A104

3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHIN THE DRAWINGS B | 14.01.2025 | PROJECT SCOPE ADJUSTMENTS: GB
[ARE TO BE REPORTED TO THE DESIGNER PRIOR TO CONSTRUCTION
4, DO NOT SCALE THIS DRAWING

COPYRIGHT:
© GT GROUP BUILDING DESIGN. THESE DRAWINGS ARE PROTECTED BY
THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED
WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.

ADDRESS

2/30 HASTINGS STREET, NOOSA HEADS QLD 4567

DRAWING

PROPOSED FLOOR PLAN - ROOF

www.gtgroup.net.qau
[email protected]
ere RPP

(07) 3298 6938

GT GROUP

[Auton Ge
| ORIGINAL SHEET SIZE: A3 [420x297mm)

 

 

Page 16

 

 

 

 

  
  

 

NOTE

UNLESS NOTED OTHERWISE, ALL EXISTING
BUILT WORKS ARE TO REMAIN. FOR FURTHER
CLARIFICATION ON EXTENT OF DEMOLITION

NOTES

1.

ALL CONSTRUCTION WORK UNDERTAKEN
IS TO COMPLY WITH THE NATIONAL
CONSTRUCTION CODE (BCA), RELEVANT

NOTE:

THESE DRAWINGS ARE DESIGN CONCEPTS
ONLY AND SHALL NOT BE USED IN ANY
WAY FOR STRUCTURAL PURPOSES. REFER

WORKS, REFER TO PROPOSED FLOOR PLAN FOR AUSTRALIAN STANDARDS AND TO STRUCTURAL ENGINEER'S DETAILS
PROPOSED RECONFIGURATION LAYOUT, WALL APPLICABLE LOCAL AUTHORITY FOR ALL MEMBER SIZES, SPECIFICATIONS
SETOUT DIMENSIONS AND OPENING LOCATIONS. REQUIREMENTS. AND SITE SPECIFIC STRUCTURAL

 

 

 

  

 

 

 

 

 

 

 

 

 

 

 

2. ALL SETBACK/SETOUT DIMENSIONS ARE REQUIREMENTS.
TO BE CHECKED AND VERIFIED ON SITE
PRIOR TO CONSTRUCTION.
AM ROOM DIMENSIONS
ADJOINING ADJOINING FINISHED WALL FACES.
VILLA VILLA eo -
ROADWAY |" BOUNDARY ADJOINING LEGEND
- a ~ VILLA ST
COL STEEL COLUMN
Pr? N _ DP DOWNPIPE
| | WC = TP TIMBER POST
1725x900mm 5e we WASTE PIPE
a?
>a
w
| Paste EREOARD COL 22 BATHROOM HEATER LIGHT AS SPECIFIED
2 EXTG, WZ su
> pp COL = 855 oO EXHAUST FAN AS SPECIFIED
| <| (EXTG.) (EXTG.) 26 ag
zZ é is ° LED DOWNLIGHT AS SPECIFIED
2
3 \
a
I EN | exoteswiseaove © guepereronroleon
CARPORT ° LAUNDRY EQUIPMENT TO iO
| | 3200xfo75mm SUIT STAIRS OVER \ CEILING FAN AS SPECIFIED
5500x3290mm z \ /
FOSHEET  xrg) 6 ~
| FFL+ 2.700 3
ao
—— NOTE:
LIGHTING LAYOUT SHOWN IS NOMINAL.
- ——o COL COL BUILDER TO CONFIRM SUITABLE LAYOUT
(EXTG) (EXTG.) __ col AGAINST ENERGY EFFICIENCY REPORT
DP (EXTG) 7 AND LOCAL AUTHORITY REQUIREMENTS
| ADJOINING AND COORDINATE WITH ELECTRICIAN.
. |
pi,
\ _ _ _ SHARED
ADJOINING | BOUNDARY | ROADWAY
fo _
SHARED ° BOUNDARY ©
ROADWAY (DEDICATED LOT
0 EXCLUSIVE USE AREA)
CRITICAL NOTE: PARTITION WALLS SHOWN ARE BASED ON 70mm WIDE STUD FOR
APPROVAL PURPOSES ONLY. REFER TO STRUCTURAL ENGINEER'S DETAILS FOR ALL
FRAMING SIZING AND STRUCTURAL REQUIREMENTS THROUGHOUT PROPOSED
WORKS. WHERE 90mm STUD FRAMES ARE REQUIRED TO SUIT PROPOSED
REFLECTED CEILING PLAN GROUND STRUCTURE, BUILDER TO MAINTAIN EXTERNAL BUILDING FOOTPRINT AND ADJUST
01 - ROOM SIZES ACCORDINGLY ON INTERNAL SIDE, ENSURING MINIMUM INTERNAL
7 SCALE 1-100 CIRCULATION WIDTHS ARE MAINTAINED (WHERE REQUIRED). ALL DIMENSIONS
SHOWN ARE FOR APPROVAL PURPOSES ONLY, STRUCTURAL LAYOUT TO BE
CONFIRMED ON SITE BY PROJECT ENGINEER & BUILDER PRIOR TO CONSTRUCTION.
NOTES: AMENDMENTS PROVECT TUNERS «AEG
1 TS ISACOMPUTER GENERATED ORAMING, DONT anENoBY KaNo,| AMENOMENTS ay ;
2 route ANE 10 BF CHECKED ONSITE PRIOR TO CONSTRUCTON ‘A | 17.08.2023] ISSUE FOR BUILDING APPROVAL GB FOR APPROVAL PROPOSED RESIDENTIAL ALTERATIONS AUG 202300 1:100,
3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHIN THE DRAWINGS B | 13.09.2023) UPDATED ISSUE FOR BUILDING APPROVAL GB ‘ADDRESS PROLECT NO. REVISION www.gtgroup.net.au
ARE TO BE REPORTED TO THE DESIGNER PRIOR TO CONSTRUCTION. C |14.01.2025) PROJECT SCOPE ADJUSTMENTS: GB 22048 Cc i. " -

GT GROUP

2/30 HASTINGS STREET, NOOSA HEADS QLD 4567

DRAWING

REFLECTED CEILING PLAN - GROUND

[email protected]
era Ie
(07) 3298 6938

COPYRIGHT:

© GT GROUP BUILDING DESIGN. THESE DRAWINGS ARE PROTECTED BY
THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED
WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.

DW, NO.

A109

| AUTHOR: GB
| ORIGINAL SHEET SIZE: A3 [420x297mm]

 

Page 17

NOTE

UNLESS NOTED OTHERWISE, ALL EXISTING
BUILT WORKS ARE TO REMAIN. FOR FURTHER
CLARIFICATION ON EXTENT OF DEMOLITION

NOTES

1. ALL CONSTRUCTION WORK UNDERTAKEN

IS TO COMPLY WITH THE NATIONAL
CONSTRUCTION CODE (BCA), RELEVANT

THESE DRAWINGS ARE DESIGN CONCEPTS
ONLY AND SHALL NOT BE USED IN ANY
WAY FOR STRUCTURAL PURPOSES. REFER

WORKS, REFER TO PROPOSED FLOOR PLAN FOR AUSTRALIAN STANDARDS AND TO STRUCTURAL ENGINEER'S DETAILS
PROPOSED RECONFIGURATION LAYOUT, WALL APPLICABLE LOCAL AUTHORITY FOR ALL MEMBER SIZES, SPECIFICATIONS
SETOUT DIMENSIONS AND OPENING LOCATIONS. REQUIREMENTS. AND SITE SPECIFIC STRUCTURAL

 

2. ALL SETBACK/SETOUT DIMENSIONS ARE REQUIREMENTS.

TO BE CHECKED AND VERIFIED ON SITE

 

 

   

 

 

 

  
   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PRIOR TO CONSTRUCTION.
NOTE:
ROOM DIMENSIONS
SHOWN ARE TO
ADJOINING ADJOINING FINISHED WALL FACES.
VILLA VILLA ° _
ROADWAY SOUNDARY ADJOINING LEGEND
7 eT ~ VILLA ————
COL STEEL COLUMN
p> N _ DP DOWNPIPE
| ; = TP TIMBER POST
PANTRY 58 wp WASTE PIPE
8
| 1950x1360mm £8 BATHROOM HEATER LIGHT AS SPECIFIED
PLASTERBOARD — 25u
= DP L 823 O EXHAUST FAN AS SPECIFIED
< EXTG. a
| gl (EXTE FL DSO S ° LED DOWNLIGHT AS SPECIFIED
S ° 1
oO
| a KITCHEN a 8 SMOKE DETECTOR TO LOCAL
3035x2275mim- f . | Ca AUTHORITY REQUIREMENTS
PLASTERBOARD Fr Is /
FL 2,560 & 12g \ CEILING FAN AS SPECIFIED
| | , on 8 ° > /
oa |S oa XN
x lg Z -
( 7 3
\ VING/DINING 3 3
fi =
_¢ 6490x3275mm = NOTE:
° PLASTERBOARD, | LIGHTING LAYOUT SHOWN IS NOMINAL.
- 6 | BUILDER TO CONFIRM SUITABLE LAYOUT
- AGAINST ENERGY EFFICIENCY REPORT
7 AND LOCAL AUTHORITY REQUIREMENTS
6 D ECK 4 & ADJOINING AND COORDINATE WITH ELECTRICIAN.
4895x2110mm = 3
BS INSULATED PANEL Ss 5 of SHARED
oO
ADJOINING “Hl so, PHVAREES BOUNDARY yal je ROADWAY
SHARED DP BOUNDARY
(DEDICATED LOT
ROADWAY EXCLUSIVE USE AREA)
CRITICAL NOTE: PARTITION WALLS SHOWN ARE BASED ON 70mm WIDE STUD FOR
APPROVAL PURPOSES ONLY. REFER TO STRUCTURAL ENGINEER'S DETAILS FOR ALL
FRAMING SIZING AND STRUCTURAL REQUIREMENTS THROUGHOUT PROPOSED
WORKS. WHERE 90mm STUD FRAMES ARE REQUIRED TO SUIT PROPOSED
STRUCTURE, BUILDER TO MAINTAIN EXTERNAL BUILDING FOOTPRINT AND ADJUST
(01 RE FLECTE D C EILIN G PLAN - LEVEL 1 ROOM SIZES ACCORDINGLY ON INTERNAL SIDE, ENSURING MINIMUM INTERNAL
- SCALE 1100 CIRCULATION WIDTHS ARE MAINTAINED (WHERE REQUIRED). ALL DIMENSIONS
YT) SHOWN ARE FOR APPROVAL PURPOSES ONLY, STRUCTURAL LAYOUT TO BE
CONFIRMED ON SITE BY PROJECT ENGINEER & BUILDER PRIOR TO CONSTRUCTION.
NOTES: AMENDMENTS PROJECT “DRAWING CREATED SCALE@A3
1 TS ISACOMPUTER GENERATED ORAMING, DONT anENoBY KaNo,| AMENOMENTS ay ;
2 route ANE 10 BF CHECKED ONSITE PRIOR TO CONSTRUCTON ‘A ] 17.08.2023] ISSUE FOR BUILDING APPROVAL GB FOR APPROVAL PROPOSED RESIDENTIAL ALTERATIONS AUG 2023 1:100
3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHIN THE DRAWINGS B | 14.01.2025) PROJECT SCOPE ADJUSTMENTS GB ‘ADDRESS PROLECT NO. REVISION www.gtgroup.net.au
" ARE TO BE REPORTED TO THE DESIGNER PRIOR TO CONSTRUCTION. C |15.01.2025| UPDATED PROJECT SCOPE ADJUSTMENTS, GB 22048 Cc

GT GROUP

2/30 HASTINGS STREET, NOOSA HEADS QLD 4567

DRAWING

REFLECTED CEILING PLAN - LEVEL 1

[email protected]
era Ie
(07) 3298 6938

COPYRIGHT:

© GT GROUP BUILDING DESIGN. THESE DRAWINGS ARE PROTECTED BY
THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED
WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.

| AUTHOR: GB
| ORIGINAL SHEET SIZE: A3 [420x297mm]

DW, NO.

A110

D

 

Page 18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE

UNLESS NOTED OTHERWISE, ALL EXISTING
BUILT WORKS ARE TO REMAIN. FOR FURTHER
CLARIFICATION ON EXTENT OF DEMOLITION

NOTES

1. ALL CONSTRUCTION WORK UNDERTAKEN
|S TO COMPLY WITH THE NATIONAL
CONSTRUCTION CODE (BCA), RELEVANT

NOTE:

THESE DRAWINGS ARE DESIGN CONCEPTS
ONLY AND SHALL NOT BE USED IN ANY
WAY FOR STRUCTURAL PURPOSES. REFER

TO STRUCTURAL ENGINEER'S DETAILS

WORKS, REFER TO PROPOSED FLOOR PLAN FOR AUSTRALIAN STANDARDS AND
PROPOSED RECONFIGURATION LAYOUT, WALL APPLICABLE LOCAL AUTHORITY FOR ALL MEMBER SIZES, SPECIFICATIONS
SETOUT DIMENSIONS AND OPENING LOCATIONS. REQUIREMENTS. AND SITE SPECIFIC STRUCTURAL

 

2, ALL SETBACK/SETOUT DIMENSIONS ARE
TO BE CHECKED AND VERIFIED ON SITE

 

 

REQUIREMENTS.

 

 

 

PRIOR TO CONSTRUCTION.
NOTE:
ROOM DIMENSIONS
N\ SHOWN ARE TO
ADJOINING ADJOINING FINISHED WALL FACES.
VILLA VILLA oq -
ROADWAY
- __ BOUNDARY ADJOINING LEGEND
T ENSUI WC VILLA Sa
Lo 2265x1570mm — 15701370mm COL STEEL COLUMN
PLASTERBOARD —PLASTERSOARD _ DP DOWNPIPE
| | = TP TIMBER POST
—~e we WASTE PIPE
— — | — — __EAVES LINE OV§ >a
| 7 <a3 BATHROOM HEATER LIGHT AS SPECIFIED
388
> bp 248 © EXHAUST FAN AS SPECIFIED
| <I (exe) ve ag
3 ° nd ° LED DOWNLIGHT AS SPECIFIED
2 Zz
3S ° °
| ® FFL+2560) | Fre 2see Ay = ‘ e SMOKE DETECTOR TO LOCAL
8 S _ AUTHORITY REQUIREMENTS
° a /
| I | ° x \ CEILING FAN AS SPECIFIED
| a % /
| / aN 8 S ~
| | r = >
| B 7 BRD 2 z a
2 « | 3655x3470rhm © 3225 ° 8 NOTE
| PLASTERBOARD PLA ARD = LIGHTING LAYOUT SHOWN IS NOMINAL
i) | FFL¥ 2.560 BUILDER TO CONFIRM SUITABLE LAYOUT
| M AGAINST ENERGY EFFICIENCY REPORT
7 AND LOCAL AUTHORITY REQUIREMENTS
ADJOINING AND COORDINATE WITH ELECTRICIAN
0 CCSCEAVESLINEOVER ff SHARED
ADJOINING BOUNDARY ROADWAY
SHARED S BOUNDARY ©
(DEDICATED LOT
ROADWAY EXCLUSIVE USE AREA)

AN

CRITICAL NOTE: PARTITION WALLS SHOWN ARE BASED ON 70mm WIDE STUD FOR
APPROVAL PURPOSES ONLY. REFER TO STRUCTURAL ENGINEER'S DETAILS FOR ALL
FRAMING SIZING AND STRUCTURAL REQUIREMENTS THROUGHOUT PROPOSED
WORKS. WHERE 90mm STUD FRAMES ARE REQUIRED TO SUIT PROPOSED
STRUCTURE, BUILDER TO MAINTAIN EXTERNAL BUILDING FOOTPRINT AND ADJUST
ROOM SIZES ACCORDINGLY ON INTERNAL SIDE, ENSURING MINIMUM INTERNAL
CIRCULATION WIDTHS ARE MAINTAINED (WHERE REQUIRED). ALL DIMENSIONS
SHOWN ARE FOR APPROVAL PURPOSES ONLY, STRUCTURAL LAYOUT TO BE
CONFIRMED ON SITE BY PROJECT ENGINEER & BUILDER PRIOR TO CONSTRUCTION.

(01 \ REFLECTED CEILING PLAN - LEVEL 2
Yo) SCALE 1:100

 

 

NOTES: AMENDMENTS PROJECT DRAWING CREATED

 

SCALE @A3
41, THIS IS A COMPUTER GENERATED DRAWING, DO NOT AMEND BYHAND.| Rey DATE —_DESCRIPTION BY FOR APPROVAL
2. THIS DRAWING SHOWS DESIGN INTENT ONLY. ALL DIMENSIONS AND AUG 2023 11
SETOUTS ARE TO BE CHECKED ON SITE PRIOR TO ConsTRUCTION. | A |17.08.2023] ISSUE FOR BUILDING APPROVAL CB PROPOSED RESIDENTIAL ALTERATIONS 00
3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHIN THE DRAWINGS | 8 | 14.01.2025] PROJECT SCOPE ADJUSTMENTS 6a ‘ADDRESS PROJECTNO. REVISION www.gtgroup.net.au
ARE TO BE REPORTED TO THE DESIGNER PRIOR TO CONSTRUCTION. C | 15.01.2025) UPDATED PROJECT SCOPE ADJUSTMENTS GB 22048 Cc i, phe ide el
4, DONO SOA PS ORANG 2/30 HASTINGS STREET, NOOSA HEADS QLD 4567 22048 Re et eee
©.GT GROUP BULLONG DESIGN. THESE DRAWINGS ARE PROTEGTED BY [AUTHOR DRAWING “er SOE
UL omc an SESE
THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED | ORIGINAL SHEET SIZE: A3 (420x297) REFLECTED CEILING PLAN - LEVEL 2 A111 Oe

 

WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.

Page 19

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

     

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE

UNLESS NOTED OTHERWISE, ALL EXISTING
BUILT WORKS ARE TO REMAIN. FOR FURTHER
CLARIFICATION ON EXTENT OF DEMOLITION

NOTES

1. ALL CONSTRUCTION WORK UNDERTAKEN
|S TO COMPLY WITH THE NATIONAL
CONSTRUCTION CODE (BCA), RELEVANT

NOTE:

THESE DRAWINGS ARE DESIGN CONCEPTS
ONLY AND SHALL NOT BE USED IN ANY

WAY FOR STRUCTURAL PURPOSES. REFER

TO STRUCTURAL ENGINEER'S DETAILS

WORKS, REFER TO PROPOSED FLOOR PLAN FOR AUSTRALIAN STANDARDS AND
PROPOSED RECONFIGURATION LAYOUT, WALL APPLICABLE LOCAL AUTHORITY FOR ALL MEMBER SIZES, SPECIFICATIONS
SETOUT DIMENSIONS AND OPENING LOCATIONS. REQUIREMENTS. AND SITE SPECIFIC STRUCTURAL

2, ALL SETBACK/SETOUT DIMENSIONS ARE
TO BE CHECKED AND VERIFIED ON SITE

 

REQUIREMENTS.

 

PRIOR TO CONSTRUCTION.
NOTE:
ROOM DIMENSIONS
N\ SHOWN ARE TO
ADJOINING ADJOINING FINISHED WALL FACES.
VILLA VILLA oq -
ROADWAY
. BOUNDARY ADJOINING LEGEND
_ _ @ - _
VILLA Se
COL STEEL COLUMN
PP N J DP DOWNPIPE
| | - TP TIMBER POST
-w we WASTE PIPE
_ _ _ _ _____EAVES LINE OV@&¥————— >a
| rT <a3 BATHROOM HEATER LIGHT AS SPECIFIED
388
> f SAG oO EXHAUST FAN AS SPECIFIED
= | aa
| 8 | | INO s ° LED DOWNLIGHT AS SPECIFIED
3 ° i oN
| |= = | 8 SMOKE DETECTOR TO LOCAL
5 6 ~ AUTHORITY REQUIREMENTS
ig a | ia
f | \
| | ¥ LOFT ¥ = ) CEILING FAN AS SPECIFIED
5 6485x5315mm (APPROX) 5 < ~
| iS PLASTERBOARD | Z
| 2 =z | a
= , =
sb q | ° ° | NOTE.
| | LIGHTING LAYOUT SHOWN IS NOMINAL.
on) | | BUILDER TO CONFIRM SUITABLE LAYOUT
| | AGAINST ENERGY EFFICIENCY REPORT
7 AND LOCAL AUTHORITY REQUIREMENTS
ADJOINING AND COORDINATE WITH ELECTRICIAN
SS CCEAVESLINEOVER st” ff SHARED
\s— = ——
ADJOINING BOUNDARY ROADWAY
SHARED S BOUNDARY ©
(DEDICATED LOT
ROADWAY EXCLUSIVE USE AREA)

(01. \ REFLECTED CEILING PLAN - LEVEL 3

 

Yo) SCALE 1:100

AN

CRITICAL NOTE: PARTITION WALLS SHOWN ARE BASED ON 70mm WIDE STUD FOR
APPROVAL PURPOSES ONLY. REFER TO STRUCTURAL ENGINEER'S DETAILS FOR ALL
FRAMING SIZING AND STRUCTURAL REQUIREMENTS THROUGHOUT PROPOSED
WORKS. WHERE 90mm STUD FRAMES ARE REQUIRED TO SUIT PROPOSED
STRUCTURE, BUILDER TO MAINTAIN EXTERNAL BUILDING FOOTPRINT AND ADJUST
ROOM SIZES ACCORDINGLY ON INTERNAL SIDE, ENSURING MINIMUM INTERNAL
CIRCULATION WIDTHS ARE MAINTAINED (WHERE REQUIRED). ALL DIMENSIONS
SHOWN ARE FOR APPROVAL PURPOSES ONLY, STRUCTURAL LAYOUT TO BE
CONFIRMED ON SITE BY PROJECT ENGINEER & BUILDER PRIOR TO CONSTRUCTION.

 

NOTES:
4, THIS IS A COMPUTER GENERATED DRAWING. DO NOT AMEND BY HAND.

AMENDMENTS

REV

DATE __DESCRIPTION

 

e FOR APPROVAL

PROJECT

DRAWING CREATED SCALE @A3

2. THIS DRAWING SHOWS DESIGN INTENT ONLY. ALL DIMENSIONS AND AUG 2023 11
SETOUTS ARE TO BE CHECKED ON SITE PRIOR TO ConSTRUCTION | A ]17.08,2023] ISSUE FOR BUILDING APPROVAL G PROPOSED RESIDENTIAL ALTERATIONS 00
3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHIN THE DRAWINGS B | 14.01.2025) PROJECT SCOPE ADJUSTMENTS Ge ‘ADDRESS PROJECTNO. REVISION www.gtgroup.net.au
ARE TO BE REPORTED TO THE DESIGNER PRIOR TO CONSTRUCTION. 22048 B drake A “
4, DONOT SCALE THIS DRAWING. 2/30 HASTINGS STREET, NOOSA HEADS QLD 4567 aes. [email protected]
cr GROUP BULOING DESIGN, THESE DRAWINGS ARE PROTECTED BY [numion cB avin ows. no Ra CSILe
THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED | ORIGINAL SHEET SIZE: A3 (420x297mm REFLECTED CEILING PLAN - LEVEL 3 A112 ODETTE)

 

WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.

 

Page 20

NOTE: LEGEND NOTE NOTES NOTE:

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

      
     

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PLANS REPRESENT GENERAL DESIGN NGL NATURAL GROUND LINE UNLESS NOTED OTHERWISE, ALL EXISTING 1. ALL CONSTRUCTION WORK UNDERTAKEN Oe a NS NO BUC frees
DEMOLITION INTENT ONLY. FULL EXTENT OF BUILT WORKS ARE TO REMAIN. FOR FURTHER IS TO COMPLY WITH THE NATIONAL OO OA RITA EUSpoNe NeEER
CLARIFICATION ON EXTENT OF DEMOLITION CONSTRUCTION CODE (BCA), RELEVANT .
DEMOLITION REQUIRED TO SUIT PROPOSED WORKS, REFER TO PROPOSED FLOOR PLAN FOR AUSTRALIAN STANDARDS AND 0 OR NE CER Sate SP OIRICATIONS
PROPOSED RECONFIGURATION LAYOUT, WALL APPLICABLE LOCAL AUTHORITY ;
WORKS TO BE CONFIRMED ON SITE. SETOUT DIMENSIONS AND OPENING LOCATIONS. REQUIREMENTS. AND SITE SPECIFIC STRUCTURAL
2. ALL SETBACK/SETOUT DIMENSIONS ARE REQUIREMENTS.
TO BE CHECKED AND VERIFIED ON SITE
PRIOR TO CONSTRUCTION.
RIDGE (APPROX. RL 12.275) RIDGE (APPROX. RL 12.275)
MO am \
DEMOLISH EXISTING EXTERNAL WALL TO
EXTENT SHOWN
x
oO
a
& = ;—
= DEMOLISH EXISTING EXTERNAL WALL
3 = TO EXTENT SHOWN
LEVEL 2 (RL7.335) ‘t |__|
Zz _ 4 — — _— — — r oo. — — — — —
ao =__—>
& UU rit = = rit ep rim
3 Wl) qe DEMOLISH EXISTING WINDOW
g| 3 Ma i
&
B I == DEMOLISH EXISTING EXTERNAL WALL
as WT \ TO EXTENT SHOWN
LEVEL (RL479)-g ILL |
3 __
— 3 | _ _ _ _ | _ _ _ _ _
re AN ee DEMOLISH EXISTING EXTERNAL WALL
Wea OXTENT SHOWN NMA TO mec Ah hi TO EXTENT SHOWN
3 iat, "We HNO UNE TONT it mi wt
z Dx MITT, JI ITT TUONO TCT CETL
Wt NPE R \ “IE DEMOLISH EXISTING EXTERNAL STAIRS Sane THIN Let ILL ni DEMOLISH EXISTING SCREEN STRUCTURE
Vail SUT te
GROUND (RL 1.91) Z IN i YES i
ACL (RL 1.91)
DEMOLISH EXISTING DOOR
‘A051 J SCALE 1:100 ‘A051 J SCALE 1:100
woes: ‘AMENDMENTS mROLECT TRANSCEND ~~ SCNE@ HS
41, THIS IS A COMPUTER GENERATED DRAWING, DO NOT AMEND BYHAND.| Rey DATE —_DESCRIPTION BY Fi R APPR VAL "
» TTOUISARE 10 SE CHECKED ONSITEPROR TOCONSTHUCTON, | A ]17.08.2023] ISSUE FOR BUILDING APPROVAL CB 0 0 PROPOSED RESIDENTIAL ALTERATIONS AUG 202300 1:00,
* eieestusteuecetarnocowmnen | ¢ |!5er us| UPDATED PReuecY SCOPE ADNSTMENTS Ss sone nue Lae benaleai
4. BOWoT SCALE TS DRAWING 2130 HASTINGS STREET, NOOSA HEADS QLD 4567 22048 ¢ GT |S} R @ lg Pp meric ues
COPYRIGHT: TamnoR Ga | rans DWG. NO, OYTO aY 7)

© GT GROUP BUILDING DESIGN. THESE DRAWINGS ARE PROTECTED BY

THE LAWS OF COPYRIGHT AND HAY NOT BE COPIED OR REPRODUCED [ORGINAL SHEET SZE:A5;«20207") | DEMOLITION EASTERN AND NORTHERN ELEVATIONS A200

WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.

(07) 3298 6938

 

Page 21

LEVEL 2 (RL 7.335)
Zz

NOTE:

PLANS REPRESENT GENERAL DESIGN
DEMOLITION INTENT ONLY. FULL EXTENT OF
DEMOLITION REQUIRED TO SUIT PROPOSED
WORKS TO BE CONFIRMED ON SITE.

RIDGE (APPROX. RL 12.275)

   
 

IEBRBE

LEGEND

NGL NATURAL GROUND LINE

 

BREE

 

ranign

DEMOLISH EXISTING EXTERNAL WALL TO
EXTENT SHOWN

 

 

 

 

 

Art

DEMOLISH EXISTING EXTERNAL WALL TO
EXTENT SHOWN

 

REMOVE EXISTING WINDOW AND RETAIN
FOR REINSTATEMENT

NOTE

UNLESS NOTED OTHERWISE, ALL EXISTING
BUILT WORKS ARE TO REMAIN. FOR FURTHER
CLARIFICATION ON EXTENT OF DEMOLITION
WORKS, REFER TO PROPOSED FLOOR PLAN FOR
PROPOSED RECONFIGURATION LAYOUT, WALL
SETOUT DIMENSIONS AND OPENING LOCATIONS.

RIDGE (APPROX. RL 12.275)
Z

NOTES

1. ALL CONSTRUCTION WORK UNDERTAKEN
|S TO COMPLY WITH THE NATIONAL
CONSTRUCTION CODE (BCA), RELEVANT
AUSTRALIAN STANDARDS AND
APPLICABLE LOCAL AUTHORITY
REQUIREMENTS.

2, ALL SETBACK/SETOUT DIMENSIONS ARE
TO BE CHECKED AND VERIFIED ON SITE
PRIOR TO CONSTRUCTION.

 

 

 

 

 

 

NOTE:

THESE DRAWINGS ARE DESIGN CONCEPTS
ONLY AND SHALL NOT BE USED IN ANY
WAY FOR STRUCTURAL PURPOSES. REFER

TO STRUCTURAL ENGINEER'S DETAILS
FOR ALL MEMBER SIZES, SPECIFICATIONS
AND SITE SPECIFIC STRUCTURAL
REQUIREMENTS.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10365 EXISTING OVERALL HEIGHT (APPROX.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DEMOLISH EXISTING WINDOW
roy
g __t DEMOLISH EXISTING WINDOW
LEVEL 1 (RL 4.79) |
Z _ _ _ _ _ _ _ _ _ _ _
| ! ! ! ig ! TTS DEMOLISH EXISTING EXTERNAL WALL TO
TTT EXTENT SHOWN
3 JTLT VTE
g VUEDVOOVOL CUCU TOTO E TYEE NU
PUVOAUANNT TAT ALULURe TE DEMOLISH EXISTING SCREEN STRUCTURE ‘ DEMOLISH EXISTING EXTERNAL WALL
GROUND (RL 1.91) TO EXTENT SHOWN (il | | | l | TO EXTENT SHOWN

 

 

 

 

 

 

 

 

 

ACL (RL 1.91)

(03 \ DEMOLITION WESTERN ELEVATION

 

‘A051 J SCALE 1:100

(04 \ DEMOLITION SOUTHERN ELEVATION

 

‘A051 J SCALE 1:100

 

1 THIS IS ACONPUTER GENERATED DRAWING, OONOT AMEND By Hano,| AMENDMENTS
2. THIS DRAWING SHOWS DESIGN INTENT ONLY. ALL DIMENSIONS AnD | Ce” __DATE_DESORIPTION
SETOUTS ARE TO BE CHECKED ON SITE PRIOR TO CONSTRUCTION, A_ ]17.08.2023] ISSUE FOR BUILDING APPROVAL
3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHIN THE DRAWINGS B | 14.01.2025 | PROJECT SCOPE ADJUSTMENTS:
[ARE TO BE REPORTED TO THE DESIGNER PRIOR TO CONSTRUCTION
4, DO NOT SCALE THIS DRAWING

COPYRIGHT:
© GT GROUP BUILDING DESIGN. THESE DRAWINGS ARE PROTECTED BY
THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED
WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.

ey FOR APPROVAL

[Auton Ge
| ORIGINAL SHEET SIZE: A3 [420x297mm)

PROJECT

PROPOSED RESIDENTIAL ALTERATIONS

ADDRESS

2/30 HASTINGS STREET, NOOSA HEADS QLD 4567

DRAWING

DEMOLITION WESTERN AND SOUTHERN ELEVATIONS

DRAWING CREATED SCALE @A3

AUG 2023 1:100

PROJECT NO, REVISION

22048 B
DWG. NO.
A201

GT GROUP

 

 

www.gtgroup.net.qau
[email protected]
ere RPP

(07) 3298 6938

Page 22

NOTE:

UNLESS NOTED OTHERWISE, ALL EXISTING
BUILT WORKS ARE TO REMAIN. GENERALLY,
PROPOSED WORKS ARE TO MATCH EXISTING.

 

 

 

 

 

 

 

 

LEGEND

NGL NATURAL GROUND LINE

NOTE

UNLESS NOTED OTHERWISE, ALL EXISTING
BUILT WORKS ARE TO REMAIN. FOR FURTHER
CLARIFICATION ON EXTENT OF DEMOLITION
WORKS, REFER TO PROPOSED FLOOR PLAN FOR
PROPOSED RECONFIGURATION LAYOUT, WALL
SETOUT DIMENSIONS AND OPENING LOCATIONS.

NOTES

1. ALL CONSTRUCTION WORK UNDERTAKEN
|S TO COMPLY WITH THE NATIONAL
CONSTRUCTION CODE (BCA), RELEVANT
AUSTRALIAN STANDARDS AND
APPLICABLE LOCAL AUTHORITY
REQUIREMENTS.

2, ALL SETBACK/SETOUT DIMENSIONS ARE
TO BE CHECKED AND VERIFIED ON SITE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE:

THESE DRAWINGS ARE DESIGN CONCEPTS
ONLY AND SHALL NOT BE USED IN ANY
WAY FOR STRUCTURAL PURPOSES. REFER

TO STRUCTURAL ENGINEER'S DETAILS
FOR ALL MEMBER SIZES, SPECIFICATIONS
AND SITE SPECIFIC STRUCTURAL
REQUIREMENTS.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PRIOR TO CONSTRUCTION.
RIDGE (APPROX. RL 13.325) RIDGE (APPROX. RL 13.325)
A ~
L. €< ROOF MOUNTED SOLAR PANEL SYSTEM
awk REFER DOOR AND WINDOW DETAILS AS SPECIFIED TO NORTH FACING SIDE OF
EXISTING ROOF
4 w
LOFT (RL 10.28)
LOFT ) | J UL HT - _ - - - - _
8 — INSULATED PANEL ROOF OVER EXISTING
a DECK TO STRUCTURAL ENGINEER'S DETAILS
<x
e| #
a| 8 800mm WIDE 'HEKA HOOD’ OR APPROVED
a EQUIVALENT WINDOW AWNINGS x2. BUILDER
= 3° PITCH TO CONFIRM SPECIFIC AWNING DETAILS WITH
LEVEL 2(RL7.535) z _— an CLIENT PRIOR TO CONSTRUCTION
= H _ — a“ 1 W - - — = —
rs +— v ve]
a a z i
3 — é 600mm WIDE 'HEKA HOOD' OR rw] € € REFER DOOR AND WINDOW DETAILS
a| APPROVED EQUIVALENT WINDOW 3 t PAINTED PVC DOWNPIPE AS SPECIFIED
Z| S AWNINGS x2, BUILDER TO CONFIRM = ps
6 SPECIFIC AWNING DETAILS WITH s ON OSM ERMA WALLS TO
LEVEL1(RL479) = CLIENT PRIOR TO CONSTRUCTION 4 | # 4
Zz a _ _ ! _ _ _ _ _
—————
€< EXTENT OF NEW EXTERNAL WALLS
TN i 1 TO MATCH EXISTING € EXTENT OF NEW EXTERNAL WALLS TO
° a = MATCH EXISTING
3 N tt
N —
WA \ ret NEW ENTRY STAIR AS SPECIFIED
GROUND (RL 1.91) Waal IN =
ACL (RL 1.91)
REFER DOOR AND WINDOW DETAILS
A100 J SCALE 1:100 A100 / SCALE 1:100
NOTES: AMENDMENTS PROJECT “DRAWINGCREATED - SCALE@A3
41, THIS IS A COMPUTER GENERATED DRAWING, DO NOT AMEND BYHAND.| Rey DATE —_DESCRIPTION BY Fi R APPR VAL "
» TTOUISARE 10 SE CHECKED ONSITEPRORTOCONSTUCHON, | A ]13.01.2025] ISSUE FOR BUILDING APPROVAL GB 0 0 PROPOSED RESIDENTIAL ALTERATIONS AUG 2023 1:100
2. ANY DISCREPANCIES OR ONISSIONS FOUND WITHINTHEDRAWNGS |B [14.01.2025] PROJECT SCOPE ADJUSTMENTS ga ADDRESS PROJECT NO, REVISION www.gtgroup.net.au
4 OONTSCAETISORAING 2130 HASTINGS STREET, NOOSA HEADS QLD 4567 i GT ( i R @ lg P er aia
1 CT ve
Ser ROUP BUILDING DESIGN. THESE DRAWINGS ARE PROTECTED BY |AutHCR $e DRAWING one. Ne (07) 3298 6938
THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED | He 297m) PROPOSED EASTERN AND NORTHERN ELEVATIONS A202

 

WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.

 

Page 23

NOTE: LEGEND NOTE NOTES NOTE:

UNLESS NOTED OTHERWISE, ALL EXISTING TT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

    

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BUILT WORKS ARE TO REMAIN, GENERALLY, NGL NATURAL GROUND LINE UNLESS NOTED OTHERWISE, ALL EXISTING 1. ALL CONSTRUCTION WORK UNDERTAKEN Oe a NS NO BUC frees
PROPOSED WORKS ARE TO MATCH EXISTING. BUILT WORKS ARE TO REMAIN. FOR FURTHER IS TO COMPLY WITH THE NATIONAL
WAY FOR STRUCTURAL PURPOSES, REFER
CLARIFICATION ON EXTENT OF DEMOLITION CONSTRUCTION CODE (BCA), RELEVANT .
WORKS, REFER TO PROPOSED FLOOR PLAN FOR AUSTRALIAN STANDARDS AND TO STRUCTURAL ENGINEER'S DETAILS
PROPOSED RECONFIGURATION LAYOUT, WALL APPLICABLE LOCAL AUTHORITY FOR ALL MEMBER SIZES, SPECIFICATIONS
SETOUT DIMENSIONS AND OPENING LOCATIONS. REQUIREMENTS. AND SITE SPECIFIC STRUCTURAL
2. ALL SETBACK/SETOUT DIMENSIONS ARE REQUIREMENTS.
TO BE CHECKED AND VERIFIED ON SITE
PRIOR TO CONSTRUCTION.
RIDGE (APPROX. RL 13.325) RIDGE (APPROX. RL. 13.325)
A.
h REFER DOOR AND WINDOW DETAILS
4
A w
LOFT (RL 10.28)
Zz _ _ LL LH LH _ _ _ _ _ Mn Ul WH _ _ _ _ i
x
oO —— — yy
ao
&
=| an TTTyk EXISTING WINDOW RELOCATED
zl S Lod LL
= T tT EXTENT OF NEW EXTERNAL WALLS. ee reoKtOS en ROOF anne oes DEY 5
LEVEL 2(RL7.535) 2 DECK TO STRUCTURAL ENGINEER'S DETAIL
LEVEL 2 ( ) 3 _ tf I __TOMATCHEXISTING = _ _ | =“ _ ST Gin 5
S —__
a
L.
B Tot EXTENT OF NEW EXTERNAL WALLS < PAINTED PVC DOWNPIPE AS SPECIFIED
&| 2 na TO MATCH EXISTING o
Z| SN < 600mm WIDE 'HEKA HOOD’ OR APPROVED g
6 EQUIVALENT WINDOW AWNINGS x2. BUILDER
LEVEL1(RL479) = TO CONFIRM SPECIFIC AWNING DETAILS WITH
Zz _ — _ __ __CLIFNT PRIOR TO CONSTRUCTION _ _ _ _ a
EXTENT OF NEW EXTERNAL WALLS
TO MATCH EXISTING Me
s
3
. N
REFER DOOR AND WINDOW DETAILS € Sa REFER DOOR AND WINDOW DETAILS
GROUND (RL 1.91) i NI
ACL (RL 1.91)
‘A100 J SCALE 1:100 ‘A100 J SCALE 1:100
wores: ‘AMENDMENTS Rover TRANSCEND —SCNE@ HS
41, THIS IS A COMPUTER GENERATED DRAWING, DO NOT AMEND BYHAND.| Rey DATE —_DESCRIPTION BY Fi R APPR VAL "
» TTOUISARE 10 SE CHECKED ONSITEPRORTOCONSTUCHON, | A ]13.01.2025] ISSUE FOR BUILDING APPROVAL CB 0 0 PROPOSED RESIDENTIAL ALTERATIONS AUG 202300 1:00
Fe eitestCusteueeetaen ocowamnen | ¢ {150 us| UPDATED PRelecT SCOPE ADNSTMENTS Ss renee nue Lae benaleai
4. BOWoT SCALE TS DRAWING 2130 HASTINGS STREET, NOOSA HEADS QLD 4567 22048 ¢ GT |S} R @ lg Pp meric ues
COPYRIGHT: [amnor Ga | rans DWG. NO, OPA

© GT GROUP BUILDING DESIGN. THESE DRAWINGS ARE PROTECTED BY

THE LAWS OF COPYRIGHT AND HAY NOT BE COPIED OR REPRODUCED [ORGINAL SHEET SZE:AS;82020Ter| | PROPOSED WESTERN AND SOUTHERN ELEVATIONS A203

WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.

(07) 3298 6938

 

 

Page 24

NOTE:

UNLESS NOTED OTHERWISE, ALL EXISTING

 

LEGEND

 

NOTE

NOTES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE:

THESE DRAWINGS ARE DESIGN CONCEPTS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

    

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

    

 

 

 

 

 

 

 

 

 

 

 

BUILT WORKS ARE TO REMAIN. GENERALLY, NGL NATURAL GROUND LINE UNLESS NOTED OTHERWISE, ALL EXISTING 1. ALL CONSTRUCTION WORK UNDERTAKEN ONLY AND SHALL NOT BE USED IN ANY
PROPOSED WORKS ARE TO MATCH EXISTING. BUILT WORKS ARE TO REMAIN. FOR FURTHER IS TO COMPLY WITH THE NATIONAL
WAY FOR STRUCTURAL PURPOSES. REFER
CLARIFICATION ON EXTENT OF DEMOLITION CONSTRUCTION CODE (BCA), RELEVANT -
WORKS, REFER TO PROPOSED FLOOR PLAN FOR AUSTRALIAN STANDARDS AND TO STRUCTURAL ENGINEER'S DETAILS
PROPOSED RECONFIGURATION LAYOUT, WALL APPLICABLE LOCAL AUTHORITY FOR ALL MEMBER SIZES, SPECIFICATIONS
SETOUT DIMENSIONS AND OPENING LOCATIONS. REQUIREMENTS. AND SITE SPECIFIC STRUCTURAL
2. ALL SETBACK/SETOUT DIMENSIONS ARE REQUIREMENTS.
TO BE CHECKED AND VERIFIED ON SITE
PRIOR TO CONSTRUCTION
RIDGE (APPROX. RL 13.325) RIDGE (APPROX. RL 13.325)
af
CEILING +2360n}n41 | r CEILING +2360 tT
+ | + mm
] oH PAINTED FLUSH SET PLASTERBOARD PAINTED FLUSH SET PLASTERBOARD
| oae WALL AND CEILING LINING WALL AND CEILING LINING
LOFT Sire LOFT
Net
| ou
oO
LOFT (RL 1028) ill ALL FRAMING TO STRUCTURAL ENGINEER'S DETAILS
_ Z. ae _ _ = _ | _ _ _ _
Wee H ~¥ z=
CEILING +2560mm ¢ WALL INSULATION TO COMPLY WITH CEILING +2560mm
io ENERGY EFFICIENCY REPORT ALL FRAMING TO STRUCTURAL ENGINEER'S
g
5 ENSUITE 1 WE 600mm WIDE 'HEKA HOOD' OR APPROVED BED2 ft. DETAILS
EQUIVALENT WINDOW AWNINGS x2, BUILDER
LEVEL 2 (RL 7.538 - TO CONFIRM SPECIFIC AWNING DETAILS WITH 3° PITCH Wal INSULATION TO COMPLY WITH
EVEL 2 (RL 7.535) | _ __ CLIENT PRIOR TO CONSTRUCTION __ — SAITCH E Le _ ENERGY EFFICIENCY REPORT -
a vy a
CEILING ¥2560mm CEILING-+2560mm,
tl «+ REFER DOOR AND WINDOW DETAILS INSULATED PANEL ROOF OVER EXISTING
9 JOINERY AS SPECIFIED DECK TO STRUCTURAL ENGINEER'S DETAILS
S KITCHEN PANTR DECK LIVING
[ Lo ‘ MEE CERSTWO ARTO PAINTED PVC DOWNPIPE AS SPECIFIED
LEVEL 1 (L479) r=] Lit ie REPLACE EXISTING
Zz | — — —_ — _ | — _ — _— —_
LING +2700mm ¢___ Wait CLADDING TO MATCH EXISTING EILING +2700mm <—___________ WALL CLADDING TO MATCH EXISTING
So CEILING +2400ehm
3 €< INTERNAL LIFT TO LIFT SUPPLIER'S €< INTERNAL LIFT TO LIFT SUPPLIER'S
8 L
“ CA LIFT, =WC DETAILS CARPORT ENTRY LIFT DETAILS
y | FIXTURES AND FITTINGS AS SPECIFIED < REFER DOOR AND WINDOW DETAILS
GROUND (RL 1.91) LY <e A
ACL (RL 1.91) f ]
REINFORCED CONCRETE GROUND SLABS 7
TO STRUCTURAL ENGINEER'S DETAILS REINFORCED CONCRETE GROUND SLABS
TO STRUCTURAL ENGINEER'S DETAILS
(A DETAIL SECTION A (8 \ DETAIL SECTION B
LT SCALE 1:100 LT) SCALE 1:100
NOTES: AMENDMENTS PROJECT “DRAWING CREATED ‘SCALE @ A3
1 TS ISACOMPUTER GENERATED ORAMING, DONT anENoBY KaNo,| AMENOMENTS ay ;
2 PrOUTS ANE TOBE CHECKED ONSITE PRIOR TO CONSTRUCTION, ‘A | 17.08.2023] ISSUE FOR BUILDING APPROVAL GB FOR APPROVAL PROPOSED RESIDENTIAL ALTERATIONS AUG 2023 1:100
2. ANY DISCREPANCIES OR OMISSIONS FOUND VITHINTHEDRAWNGS | 8 |13.09.2023| UPDATED ISSUE FOR BUILDING APPROVAL ga ADDRESS PROJECT NO, REVISION Mamet Mariel]
4 tonorscamisomnns  MORTOOASTHETON. | | 1501 2005| UPDATED PROJECT SCOPE ADJUSTMENTS 8 2/30 HASTINGS STREET, NOOSA HEADS QLD 4567 awe _D GT GROUP Dis RSET ache

COPYRIGHT:

© GT GROUP BUILDING DESIGN. THESE DRAWINGS ARE PROTECTED BY
THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED
WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.

| AUTHOR: GB

| ORIGINAL SHEET SIZE: A3 [420x297mm]

DRAWING

DETAIL SECTIONS A AND B

DW, NO.

A300

 

Orsay
(07) 3298 6938

 

Page 25

NOTE: DIMENSIONS SHOWN FOR DOORS AND WINDOWS REPRESENT LEGEND NOTES

N\ PHYSICAL OPENING SIZES. FRAME MANUFACTURER TO INCREASE FG - FIXED GLAZING. 1. REFER FLOOR PLAN FOR OPENING DIRECTION OF ALL WINDOWS AND DOORS.
SIZES OF STUD OPENINGS AS REQUIRED TO SUIT DOOR AND WINDOW 2. DOOR AND WINDOW FRAWING FINISH TO BE CONFIRMED BY CLIENT AND/OR
MANUFACTURER'S REQUIREMENTS. 3. FRAME DIMENSIONS SHOWN ARE NOMINAL. DOORS AND WINDOWS TO BE PRICED

BASED ON THE CLOSEST STANDARD SIZE TO THAT SHOWN.

4. ALL GLAZING SHALL COMPLY WITH AS1288

5. GLASS THICKNESS SHALL BE DESIGNED BY THE DOOR & WINDOW SUPPLIER TO
SUIT LOCAL WIND CONDITIONS.

6. UNLESS NOTED OTHERWISE, ALL GLAZING SHALL BE CLEAR FINISH.

7, ALL OPENABLE DOOR AND WINDOW FRAMES (INCLUDING LOUVRE WINDOWS) ARE
TO ALLOW FOR INSTALLATION OF INSECT OR 'CRIMSAFE' SECURITY SCREENING.

8. ALL GLAZING TO COMPLY WITH THE REQUIREMENTS NOTED IN THE SITE SPECIFIC
ENERGY EFFICIENCY ASSESSMENT AND REPORT.

9. BUILDER TO ALLOW FOR DOUBLE GLAZED WINDOWS AND DOORS IN CONTRACT
(WHERE DESIGN ALLOWS). CONFIRM WITH CLIENT PRIOR TO CONSTRUCTION.

2100 770

~
gq
°

|
|
|

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

e
\ / / z |
Cu
og |
gs S So — Ze
2] f s) (>= | se
Ba
/ \ \] a |
oO
FFL |
vw — — F ~~ F ~~ F a ~~ a ~~ a ~~ a ~~
ALUMINIUM FRAME. TIMBER FRAME. TIMBER FRAME. TIMBER FRAME.
2100 1500
8 hii FG
. = a | 47 ie
~~
s
2 3
gS — Ss
a s
3 N
g 8
8
s
FEL =
WZ —_ —_ ; —_ —_ —_ ; —_ —_ —_ —_ —_ —_ —_ —_ _ —_
e
8
01 02 031 104 05 NOTE: ALL PROPOSED WINDOWS TO MATCH
SN EXISTING. BUILDER TO CONFIRM ON SITE WINDOW
ALUMINIUM FRAMED ALUMINIUM FRAMED ALUMINIUM FRAMED ALUMINIUM FRAME
AWNING WINDOW FIXED GLASS WINDOW AWNING WINDOW SLIDING WINDOW. TYPES AND SIZES PRIOR TO CONSTRUCTION.
(TO BE CONFIRMED). (TO BE CONFIRMED). (TO BE CONFIRMED).
NOTES: AMENDMENTS PROJECT “DRAWINGCREATED  -- SCALE@A3
1, THISIS A COMPUTER GENERATED DRAWING. DO NOTAMENDBY KAND.| Rey parE DESCRIPTION ay ;
» route ANE 10 BF CHECKED ONSITE PRIOR TO CONSTRUCT, ‘A | 17.08.2023] ISSUE FOR BUILDING APPROVAL GB FOR APPROVAL PROPOSED RESIDENTIAL ALTERATIONS AUG 2023 1:50
2. ANY DISCREPANCIES OR OMISSIONS FOUND WITHINTHEDRAWNGS | 8 |13.09.2023| UPDATED ISSUE FOR BUILDING APPROVAL ga ADDRESS PROLECT NO. REVISION Mime etre sareiselt)
«Bonorsone BoM NRTPCOASTTON | 1501 2n25| UPDATED PROVECT SCOPE ADWUSTHENTS ce 2/30 HASTINGS STREET, NOOSA HEADS QLD 4567 on oT GROUP RreRGIS eM aaTe
COPYRIGHT: [amor ce | rns DWG, NO. 0410 063 172

(© GT GROUP BUILDING DESIGN. THESE DRAWINGS ARE PROTECTED BY

THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED [ ORIGINAL SHEET SIZE: A3 [4201297 mm] DOOR AND WINDOW SCHEDULE A400 (07) 3298 6938

WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.

 

 

Used in these records

About this file

File size
10.2 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Change proposal plans.pdf · 10.2 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.