Change proposal plans · 51983.3225.22
Plans and drawings: the text below has words only, no drawings.
Very large file (10.2 MB): may take a few minutes to open.
GENERAL NOTES : TIMBER FRAMING DESIGNED IN ACCORDANCE WITH NCC VOL. 2 PART 3.4 & AS.1684-2010. RESIDENTIAL TIMBER FRAMED CONSTRUCTION BLOCKWORK MASONRY DESIGNED IN ACCORDANCE WITH SINGLE LEAF MASONRY - C.M.A.A. (CM02-2014). MASONRY CONSTRUCTION TO COMPLY WITH NCC VOL. 2 PART 3.3 & AS.3700-2011, MASONRY STRUCTURES). PLYWOOD BRACING DESIGNED IN ACCORDANCE WITH STRUCTURAL PLYWOOD WALL BRACING - P.A.A. (COMPLIES WITH AS.1684.2-2010). STEEL SECTIONS DESIGNED IN ACCORDANCE WITH STRUCTURAL STEEL IN HOUSING 'THIRD EDITION’ (COMPLIES WITH AS4100-1998 STEEL STRUCTURES). WIND LOADING CALCULATIONS IN ACCORDANCE WITH AS.4055-2012. WIND LOADS FOR HOUSING STORM WATER DRAINAGE TO COMPLY WITH NCC VOL. 2 PART 3.1.2 & AS/NZS.3500.3-2003 OR AS.3500.5-2000 AND COUNCIL REQUIREMENTS. TERMITE PROTECTION TO COMPLY WITH NCC VOL. 2 PART 3.1.3 & AS.3660.1-2000 AND MANUFACTURER'S SPECIFICATIONS. SUB-FLOOR VENTILATION MUST COMPLY WITH NCC VOL. 2 PART 3.4.1. *400mm MIN. CLEARANCE TO UNDERSIDE OF LOWEST TIMBER MEMBER*. ROOF & WALL CLADDING AND GUTTERS & DOWNPIPES TO COMPLY WITH NCC VOL. 2 PART 3.5 GLAZING TO COMPLY WITH NCC VOL. 2 PART 3.6 & AS.2047-2014 & AS.1288-2006. SMOKE ALARMS MUST COMPLY WITH THE REQUIREMENTS OF THE NCC VOL. 2 PART 3.7.2 AND AS.3786-2014. *MUST BE HARD WIRED TO MAINS POWER*. ALL WET AREAS TO COMPLY WITH NCC VOL. 2 PART 3.8.1 & AS.3740-2010. W.C. DOOR TO COMPLY WITH NCC VOL. 2 PART 3.8.3.3. LIGHTING TO COMPLY WITH NCC VOL. 2 PART 3.8.4 VENTILATION TO COMPLY WITH NCC VOL. 2 PART 3.8.5 SOUND INSULATION TO COMPLY WITH NCC VOL. 2 PART 3.8.6 TREADS & RISERS TO COMPLY WITH NCC PART 3.9.1 BALUSTRADE & HANDRAILS TO COMPLY WITH NCC PART 3.9.2 & ASINZS.1170.1-2002. SWIMMING POOL FENCE/ GATE TO COMPLY WITH NCC VOL. 2 PART 3.9.3, AS.1926.1-2007 & QDC MP3.4. ENERGY EFFICIENCY TO COMPLY WITH NCC VOL. 2 PART 3.12 OR RECOGNISED ENERGY RATING SYSTEM. ALL RELEVANT WORKS TO COMPLY WITH THE NATIONAL CONSTRUCTION CODE (NCC) - BUILDING CODE OF AUSTRALIA - CLASS 1 AND CLASS 10 BUILDINGS. ALL ANCILLARY WORKS TO BE UNDERTAKEN IN ACCORDANCE WITH THE MANUFACTURERS SPECIFICATION SUSTAINABLE HOUSING REQUIREMENTS: NEW DWELLING REQUIREMENTS THE LAWS APPLY TO NEW HOUSES (CLASS 1a), TOWNHOUSES (CLASS 1b), AND MAJOR RENOVATIONS. A NUMBER OF NEW LAWS CAME INTO EFFECT ON 26TH NOV. 2010 WHICH REPLACES THE EXISTING VERSION OF MP 4.1 PUBLISHED ON 30TH JULY 2010. THIS GUIDELINE COVERS THE REQUIREMENTS FOR (CLIMATE ZONE 3): * 6-STAR (CLASS 1 BUILDINGS) [5-STAR MIN SOFTWARE RATING + OPTIONAL CREDITS] ENERGY EQUIVALENCE FOR NEW HOUSES AND TOWNHOUSES ; * OPTIONAL CREDITS FOR COVERED OUTDOOR LIVING AREAS, SUCH AS DECKS AND VERANDAHS AND; + ENERGY EFFICIENT LIGHTING FOR NEW HOUSES, TOWNHOUSES ENERGY EFFICIENT LIGHTING FOR A MINIMUM OF 80% FLOOR AREA ENERGY EFFICIENT FIXTURES REQUIREMENTS IN CLASS 1a, CLASS 1b AND CLASS 2 BUILDINGS: + LIGHT FITTINGS MUST BE ENERGY EFFICIENT LIGHTING FOR A MINIMUM OF 80% OF THE TOTAL INTERNAL FLOOR AREA. ENERGY EFFICIENT LIGHTING: INCLUDES FLUORESCENT AND COMPACT FLUORESCENT LIGHTS. IT DOES NOT INCLUDE INCANDESCENT OR HALOGEN. + AIR CONDITIONERS NEW AND REPLACEMENT AIR-CONDITIONERS MUST HAVE AN E.E.R. OF AT LEAST 2.9. + HOT WATER SYSTEMS HOT WATER SYSTEMS MUST COMPLY WITHE QUEENSLAND PLUMBING AND WASTE WATER CODE A SUITABLE HOT WATER SYSTEM INCLUDES: (A) A GAS HOT WATER SYSTEM WITH A FIVE STAR ENERGY RATING; OR (B) A HEAT PUMP OR A SOLAR HOT WATER SYSTEM WHERE: (I) IN A BUILDING WITH 3 OR MORE BEDROOMS, THE HOT WATER SYSTEM, MUST BE ELIGIBLE TO RECEIVE AT LEAST 22 RENEWABLE ENERGY CERTIFICATES; OR (II) IN A BUILDING WITH 1 OR 2 BEDROOMS THE HOT WATER SYSTEM MUST BE ELIGIBLE TO RECEIVE AT LEAST 14 RENEWABLE ENERGY CERTIFICATES. WATER CONSERVATIVE FIXTURE REQUIREMENTS THE FOLLOWING WATER CONSERVATION FIXTURES MUST BE INSTALLED THROUGHOUT THE DWELLING: + WATER PRESSURE WATER PRESSURE LIMITING: (TO RETICULATED MAINS WATER SUPPLY AREAS ONLY IF REQUIRED BY LOCAL GOVT.) THE MAXIMUM PRESSURE LEVEL OF WATER FROM ANY OUTLET WITHIN THE PROPERTY BOUNDARIES MUST NOT EXCEED S00KPA. + TOILETS DUAL FLUSH TOILETS: A TOILET MUST HAVE A DUAL FLUSH CAPACITY THAT DOES NOT EXCEED 6 LITRES ON FULL FLUSH AND 3 LITRES ON HALF FLUSH. * TAPWARE MIN. 3-STAR WELS RATED FOR KITCH. SINKS, BASINS AND LAUNDRY TUBS. + SHOWER HEADS TO RETICULATED MAINS WATER SUPPLY AREAS ONLY, TO BE 3 STAR RATING UNDER THE WATER EFFICIENCY LABELLING SCHEME (WELS) OR AAA RATING WHEN ASSESSED AGAINST AS/NZ 6400:2005 WATER EFFICIENT PRODUCTS - RATING AND LABELLING. REFER: Queensland Development Code Mandatory Part 4.1 Sustainable buildings Guideline-version 12th November 2010 FOR ADDITIONAL SPECIFICS. WORKPLACE HEALTH AND SAFTEY REQUIREMENTS: EXCAVATION AND TRENCHES BEFORE EXCAVATION WORK IS CARRIED OUT, THE RELEVANT PERSON OR PRINCIPAL CONTRACTOR, FOR CONSTRUCTION WORK, MUST FIND OUT WHAT UNDERGROUND SERVICES EXIST IN THE AREA, AND OTHER RELEVANT INFORMATION A RELEVANT PERSON MUST IMPLEMENT ANY CONTROL MEASURES NECESSARY TO PREVENT RISK: (a) AN EXCAVATION COLLAPSING, (b) OBJECTS FALLING INTO AN EXCAVATION, (c) APERSON FALLING INTO AN EXCAVATION, (d) SUBSTANCE EXPOSURE IN AN EXCAVATION, (ie. CARBON MONOXIDE FROM PLANT). (e) FROM THE COLLAPSE OF ANOTHER STRUCTURE (ie. ADJOINING BUILDING OR ROAD). TRENCHES BATTERING AND SHORING FOR TRENCHES TO BE IN ACCORDANCE WITH WORKPLACE HEALTH AND SAFTEY REQUIREMENTS. WRITTEN APPROVAL TO VARY THE BENCHING AND BATTERING REQUIREMENTS MAY BE OBTAINED FROM AN ENGINEER. THE APPROVAL MUST BE KEPT ON SITE AT ALL TIMES. LADDERS USED FOR ACCESS MUST BE NO MORE THAN 9 METRES APART IN THE AREA OF THE TRENCH WHERE WORK WILL BE CARRIED OUT. WORK AT HEIGHTS RISKS MUST BE MANAGED IF A PERSON COULD FALL. FACTORS SUCH AS THE TYPE OF ACTIVITY BEING CARRIED OUT SHOULD BE TAKEN INTO CONSIDERATION TO ESTABLISH THE DEGREE OF RISK. CONTROL MEASURES USED TO MANAGE RISKS MUST COMPLY WITH REGULATORY REQUIREMENTS. RELEVANT PEOPLE CARRYING OUT WORK AS OUTLINED IN THE WORKPLACE HEALTH AND SAFTEY REQUIREMENTS MUST: (a) PREVENT A FALL; OR (b) IF PREVENTION IS NOT POSSIBLE, ARREST THE FALL AND PREVENT OR MINIMISE THE RISK OF DEATH OR INJURY FROM THE ARREST OF THE FALL. LADDERS, TRESTLES AND SCAFFOLDING RELEVANT PEOPLE MUST PREVENT OR MINIMISE RISKS FROM USING A LADDER. RELEVANT PEOPLE MUST PREVENT OR MINIMISE RISKS FROM WORKING ON A PLATFORM SUPPORTED BY A TRESTLE LADDER. ALL LADDERS, TRESTLES AND SCAFFOLDING TO BE IN ACCORDANCE WITH WORKPLACE HEALTH AND SAFTEY REQUIREMENTS. PROTECTION FROM FALLING OBJECTS PRINCIPAL CONTRACTORS AND RELEVANT PEOPLE MUST TAKE PRECAUTIONS TO ENSURE THAT OBJECTS DO NOT FALL ONTO OR HIT PEOPLE DOING CONSTRUCTION WORK AND PEOPLE IN ADJOINING AREAS. PRINCIPAL CONTRACTORS MUST ASSESS THE RISK FROM FALLING OBJECTS AND USE CONTROLS TO PREVENT OR MINIMISE THE RISKS THE CONTROLS CHOSEN MUST COMPLY WITH ANY REGULATORY REQUIREMENTS. DEMOLITION WORK AND ASBESTOS REMOVAL DEMOLITION WORK OR ASBESTOS REMOVAL WORK (PRESCRIBED ACTIVITIES) ARE NOW CONSIDERED AS CONSTRUCTION WORK. PEOPLE PERFORMING THIS TYPE OF WORK MUST NOW COMPLY WITH THE CONSTRUCTION RELATED REGULATIONS. DEMOLITION WORK INCLUDES THE: (a) DEMOLITION OR SYSTEMATIC DISMANTLING OF A BUILDING OR OTHER STRUCTURE, OR PART OF A BUILDING OR OTHER STRUCTURE (b) NOT INCLUDING THE SYSTEMATIC DISMANTLING OF A PART OF A BUILDING OR OTHER STRUCTURE FOR ALTERATION, MAINTENANCE, REMODELLING OR REPAIR DEMOLITION WORK INVOLVING THE REMOVAL OF ASBESTOS MATERIALS, INCLUDING FIBRO SHEETING, NEEDS EXTRA SAFETY PRECAUTIONS. ASBESTOS REMOVAL WORK MUST BE DONE IN ACCORDANCE WITH THE NATIONAL CODE OF PRACTICE FOR THE SAFE REMOVAL OF ASBESTOS 2ND EDITION [NOHSC:2002 (2005). FLOOD HAZARD REQUIREMENTS: FLOOD HAZARD AREA AREAS SUBJECT TO FLOODING ARE TO COMPLY WITH QDC MP3.5 AND THE NATIONAL FLOOD STANDARD, WHICH INCLUDES THE FOLLOWING: + STRUCTURAL ENGINEER TO PROVIDE CONFIRMATION THAT THE FOOTING, SLAB AND SUBFLOOR HAS BEEN DESIGNED TO. MEET FLOOD ACTIONS SPECIFIED IN SECTION 2.3 OF THE NATIONAL FLOOD STANDARD. + STRUCTURAL ENGINEER TO SPECIFY THE NECESSARY DURABILITY AND CORROSION PROTECTION OF MATERIALS LOCATED BELOW THE DEFINED FLOOD HAZARD LEVEL, IN ACCORDANCE WITH SECTION 2.8 OF THE FLOOD HAZARD CODE. + ELECTRICAL SWITCHES ARE TO BE PLACED ABOVE THE FLOOD HAZARD LEVEL. + ELECTRICAL CONDUITS AND CABLES INSTALLED BELOW THE FLOOD HAZARD LEVEL MUST BE WATERPROOFED OR PLACED IN WATERPROOFED ENCLOSURES. + UTILITIES SUCH AS METERBOARDS, HOT WATER SYSTEMS AND GAS BOTTLES ARE TO BE LOCATED ABOVE THE FLOOD HAZARD LEVEL. + SANITARY DRAINAGE SYSTEM TO BE PROTECTED FROM BACKFLOW USING A REFLUX VALVE FITTED BETWEEN THE BUILDING AND SEWER CONNECTION POINT. DRAINAGE DEFICIENT AREA SITE TO BE FILLED AND GRADED TO LEVELS AS PER FIGURE 2 OF SUNSHINE COAST REGIONAL COUNCIL'S FLOOD REPORT. LICENSED BUILDING SURVEYOR TO PROVIDE EVIDENCE THAT THE MODIFIED SITE SURFACE LEVELS HAVE BEEN CONSTRUCTED IN ACCORDANCE WITH THE REPORT. THs |S ACONPUTER GENERATED DRAWING, DO NOT auenD ey Hav, | AMENDMENTS 4. TH ul PI 2. THIS DRAWING SHOWS DESIGN INTENT ONLY. ALL DIMENSIONS AND | —e¥_DATE_DESCRPTION PROJECT ey FOR APPROVAL SETOUTS ARE TO BE CHECKED ON SITE PRIOR TO CONSTRUCTION. A_ ]17.08.2023] ISSUE FOR BUILDING APPROVAL 3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHIN THE DRAWINGS B | 14.01.2025 | PROJECT SCOPE ADJUSTMENTS: [ARE TO BE REPORTED TO THE DESIGNER PRIOR TO CONSTRUCTION 4, DO NOT SCALE THIS DRAWING COPYRIGHT: (© GT GROUP BUILDING DESIGN. THESE DRAWINGS ARE PROTECTED BY THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN. ce PROPOSED RESIDENTIAL ALTERATIONS AUG 2023 ce ADDRESS: PROJECT NO. 2/30 HASTINGS STREET, NOOSA HEADS QLD 4567 22008 [auor:¢s | awe | ORIGINAL SHEET SIZE: A3 (420x207mm] GENERAL NOTES DRAWING CREATED ‘SCALE @A3 www.gtgroup.net.qau [email protected] ere RPP (07) 3298 6938 GT GROUP
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Change proposal plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 10.2 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.