Council archive · source document
Change proposal plans · 51983.3225.22
Plans and drawings: the text below has words only, no drawings.
Very large file (10.2 MB): may take a few minutes to open.
ADJOINING
VILLA
BOUNDARY
ADJOINING
VILLA
ROADWAY
ADJOINING
SHARED
4
q
BOUNDARY,
ROADWAY
ADJOINING
VILLA
~ BOUNDARY
~~ “BOUNDARY ©
(DEDICATED LOT
EXCLUSIVE USE AREA)
BOUNDARY
(DEDICATED LOT
EXCLUSIVE USE AREA)
7
7
(01. \ PROPOSED FLOOR PLAN - ROOF
Yo) SCALE 1:100
NOTE
UNLESS NOTED OTHERWISE, ALL EXISTING
BUILT WORKS ARE TO REMAIN. FOR FURTHER
CLARIFICATION ON EXTENT OF DEMOLITION
NOTES
1. ALL CONSTRUCTION WORK UNDERTAKEN
|S TO COMPLY WITH THE NATIONAL
CONSTRUCTION CODE (BCA), RELEVANT
NOTE:
THESE DRAWINGS ARE DESIGN CONCEPTS
ONLY AND SHALL NOT BE USED IN ANY
WAY FOR STRUCTURAL PURPOSES. REFER
TO STRUCTURAL ENGINEER'S DETAILS
WORKS, REFER TO PROPOSED FLOOR PLAN FOR AUSTRALIAN STANDARDS AND
PROPOSED RECONFIGURATION LAYOUT, WALL APPLICABLE LOCAL AUTHORITY FOR ALL MEMBER SIZES, SPECIFICATIONS
SETOUT DIMENSIONS AND OPENING LOCATIONS. REQUIREMENTS. AND SITE SPECIFIC STRUCTURAL
ROOF MOUNTED SOLAR
PANEL SYSTEM AS SPECIFIED
TO NORTH FACING SIDE OF
EXISTING ROOF
BOUNDARY
ADJOINING
SHARED
ROADWAY
2, ALL SETBACK/SETOUT DIMENSIONS ARE
TO BE CHECKED AND VERIFIED ON SITE
PRIOR TO CONSTRUCTION.
AN
REQUIREMENTS.
NOTE:
ROOM DIMENSIONS
SHOWN ARE TO
FINISHED WALL FACES.
LEGEND
AW — AWNING WINDOW
COL STEEL COLUMN
CT COOKTOP
DHW DOUBLE HUNG WINDOW
DP = DOWNPIPE
DRY CLOTHES DRYER
FW FLOOR WASTE
DW DISHWASHER
FGW FIXED GLASS WINDOW
HB HAND BASIN
LVW LOUVRE WINDOW
OV OVEN
P PANTRY
REF REFRIGERATOR
SGD SLIDING GLASS DOOR
SGW SLIDING GLASS WINDOW
SHR SHOWER
SWP SANITARY WASTE PIPE
wc TOILET
WM WASHING MACHINE
CRITICAL NOTE: PARTITION WALLS SHOWN ARE BASED ON 70mm WIDE STUD FOR
APPROVAL PURPOSES ONLY. REFER TO STRUCTURAL ENGINEER'S DETAILS FOR ALL
FRAMING SIZING AND STRUCTURAL REQUIREMENTS THROUGHOUT PROPOSED
WORKS. WHERE 90mm STUD FRAMES ARE REQUIRED TO SUIT PROPOSED
STRUCTURE, BUILDER TO MAINTAIN EXTERNAL BUILDING FOOTPRINT AND ADJUST
ROOM SIZES ACCORDINGLY ON INTERNAL SIDE, ENSURING MINIMUM INTERNAL
CIRCULATION WIDTHS ARE MAINTAINED (WHERE REQUIRED). ALL DIMENSIONS
SHOWN ARE FOR APPROVAL PURPOSES ONLY, STRUCTURAL LAYOUT TO BE
CONFIRMED ON SITE BY PROJECT ENGINEER & BUILDER PRIOR TO CONSTRUCTION.
NOTES:
4, THIS IS A COMPUTER GENERATED DRAWING. DO NOT AMEND BY HAND.
2. THIS DRAWING SHOWS DESIGN INTENT ONLY. ALL DIMENSIONS AND
SETOUTS ARE TO BE CHECKED ON SITE PRIOR TO CONSTRUCTION.
AMENDMENTS
REV
A |17.08,2023] ISSUE FOR BUILDING APPROVAL
DATE __DESCRIPTION
ee FOR APPROVAL
PROJECT
PROPOSED RESIDENTIAL ALTERATIONS
DRAWING CREATED SCALE @A3
AUG 2023 1:100
PROJECT NO, REVISION
22048 B
DWG, NO,
A104
3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHIN THE DRAWINGS B | 14.01.2025 | PROJECT SCOPE ADJUSTMENTS: GB
[ARE TO BE REPORTED TO THE DESIGNER PRIOR TO CONSTRUCTION
4, DO NOT SCALE THIS DRAWING
COPYRIGHT:
© GT GROUP BUILDING DESIGN. THESE DRAWINGS ARE PROTECTED BY
THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED
WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.
ADDRESS
2/30 HASTINGS STREET, NOOSA HEADS QLD 4567
DRAWING
PROPOSED FLOOR PLAN - ROOF
www.gtgroup.net.qau
[email protected]
ere RPP
(07) 3298 6938
GT GROUP
[Auton Ge
| ORIGINAL SHEET SIZE: A3 [420x297mm)
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Change proposal plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 10.2 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.