Change proposal plans · 51983.3225.22
Plans and drawings: the text below has words only, no drawings.
Very large file (10.2 MB): may take a few minutes to open.
NOTE UNLESS NOTED OTHERWISE, ALL EXISTING BUILT WORKS ARE TO REMAIN. FOR FURTHER CLARIFICATION ON EXTENT OF DEMOLITION NOTES 1. ALL CONSTRUCTION WORK UNDERTAKEN IS TO COMPLY WITH THE NATIONAL CONSTRUCTION CODE (BCA), RELEVANT NOTE: THESE DRAWINGS ARE DESIGN CONCEPTS ONLY AND SHALL NOT BE USED IN ANY WAY FOR STRUCTURAL PURPOSES. REFER WORKS, REFER TO PROPOSED FLOOR PLAN FOR AUSTRALIAN STANDARDS AND TO STRUCTURAL ENGINEER'S DETAILS PROPOSED RECONFIGURATION LAYOUT, WALL APPLICABLE LOCAL AUTHORITY FOR ALL MEMBER SIZES, SPECIFICATIONS SETOUT DIMENSIONS AND OPENING LOCATIONS. REQUIREMENTS. AND SITE SPECIFIC STRUCTURAL 2. ALL SETBACK/SETOUT DIMENSIONS ARE REQUIREMENTS. TO BE CHECKED AND VERIFIED ON SITE PRIOR TO CONSTRUCTION. AM ROOM DIMENSIONS ADJOINING ADJOINING FINISHED WALL FACES. VILLA VILLA eo - ROADWAY |" BOUNDARY ADJOINING LEGEND - a ~ VILLA ST COL STEEL COLUMN Pr? N _ DP DOWNPIPE | | WC = TP TIMBER POST 1725x900mm 5e we WASTE PIPE a? >a w | Paste EREOARD COL 22 BATHROOM HEATER LIGHT AS SPECIFIED 2 EXTG, WZ su > pp COL = 855 oO EXHAUST FAN AS SPECIFIED | <| (EXTG.) (EXTG.) 26 ag zZ é is ° LED DOWNLIGHT AS SPECIFIED 2 3 \ a I EN | exoteswiseaove © guepereronroleon CARPORT ° LAUNDRY EQUIPMENT TO iO | | 3200xfo75mm SUIT STAIRS OVER \ CEILING FAN AS SPECIFIED 5500x3290mm z \ / FOSHEET xrg) 6 ~ | FFL+ 2.700 3 ao —— NOTE: LIGHTING LAYOUT SHOWN IS NOMINAL. - ——o COL COL BUILDER TO CONFIRM SUITABLE LAYOUT (EXTG) (EXTG.) __ col AGAINST ENERGY EFFICIENCY REPORT DP (EXTG) 7 AND LOCAL AUTHORITY REQUIREMENTS | ADJOINING AND COORDINATE WITH ELECTRICIAN. . | pi, \ _ _ _ SHARED ADJOINING | BOUNDARY | ROADWAY fo _ SHARED ° BOUNDARY © ROADWAY (DEDICATED LOT 0 EXCLUSIVE USE AREA) CRITICAL NOTE: PARTITION WALLS SHOWN ARE BASED ON 70mm WIDE STUD FOR APPROVAL PURPOSES ONLY. REFER TO STRUCTURAL ENGINEER'S DETAILS FOR ALL FRAMING SIZING AND STRUCTURAL REQUIREMENTS THROUGHOUT PROPOSED WORKS. WHERE 90mm STUD FRAMES ARE REQUIRED TO SUIT PROPOSED REFLECTED CEILING PLAN GROUND STRUCTURE, BUILDER TO MAINTAIN EXTERNAL BUILDING FOOTPRINT AND ADJUST 01 - ROOM SIZES ACCORDINGLY ON INTERNAL SIDE, ENSURING MINIMUM INTERNAL 7 SCALE 1-100 CIRCULATION WIDTHS ARE MAINTAINED (WHERE REQUIRED). ALL DIMENSIONS SHOWN ARE FOR APPROVAL PURPOSES ONLY, STRUCTURAL LAYOUT TO BE CONFIRMED ON SITE BY PROJECT ENGINEER & BUILDER PRIOR TO CONSTRUCTION. NOTES: AMENDMENTS PROVECT TUNERS «AEG 1 TS ISACOMPUTER GENERATED ORAMING, DONT anENoBY KaNo,| AMENOMENTS ay ; 2 route ANE 10 BF CHECKED ONSITE PRIOR TO CONSTRUCTON ‘A | 17.08.2023] ISSUE FOR BUILDING APPROVAL GB FOR APPROVAL PROPOSED RESIDENTIAL ALTERATIONS AUG 202300 1:100, 3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHIN THE DRAWINGS B | 13.09.2023) UPDATED ISSUE FOR BUILDING APPROVAL GB ‘ADDRESS PROLECT NO. REVISION www.gtgroup.net.au ARE TO BE REPORTED TO THE DESIGNER PRIOR TO CONSTRUCTION. C |14.01.2025) PROJECT SCOPE ADJUSTMENTS: GB 22048 Cc i. " - GT GROUP 2/30 HASTINGS STREET, NOOSA HEADS QLD 4567 DRAWING REFLECTED CEILING PLAN - GROUND [email protected] era Ie (07) 3298 6938 COPYRIGHT: © GT GROUP BUILDING DESIGN. THESE DRAWINGS ARE PROTECTED BY THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN. DW, NO. A109 | AUTHOR: GB | ORIGINAL SHEET SIZE: A3 [420x297mm]
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Change proposal plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 10.2 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.