Skip to the record
The first. The best. The only NoosaWatch™.

Council archive · source document

Change proposal plans · 51983.3225.22

of 25

Check the original when the exact wording matters.

Plans and drawings: the text below has words only, no drawings.

Very large file (10.2 MB): may take a few minutes to open.

Log in to see the plans as drawn
NOTE

UNLESS NOTED OTHERWISE, ALL EXISTING
BUILT WORKS ARE TO REMAIN. FOR FURTHER
CLARIFICATION ON EXTENT OF DEMOLITION

NOTES

1. ALL CONSTRUCTION WORK UNDERTAKEN

IS TO COMPLY WITH THE NATIONAL
CONSTRUCTION CODE (BCA), RELEVANT

THESE DRAWINGS ARE DESIGN CONCEPTS
ONLY AND SHALL NOT BE USED IN ANY
WAY FOR STRUCTURAL PURPOSES. REFER

WORKS, REFER TO PROPOSED FLOOR PLAN FOR AUSTRALIAN STANDARDS AND TO STRUCTURAL ENGINEER'S DETAILS
PROPOSED RECONFIGURATION LAYOUT, WALL APPLICABLE LOCAL AUTHORITY FOR ALL MEMBER SIZES, SPECIFICATIONS
SETOUT DIMENSIONS AND OPENING LOCATIONS. REQUIREMENTS. AND SITE SPECIFIC STRUCTURAL

 

2. ALL SETBACK/SETOUT DIMENSIONS ARE REQUIREMENTS.

TO BE CHECKED AND VERIFIED ON SITE

 

 

   

 

 

 

  
   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PRIOR TO CONSTRUCTION.
NOTE:
ROOM DIMENSIONS
SHOWN ARE TO
ADJOINING ADJOINING FINISHED WALL FACES.
VILLA VILLA ° _
ROADWAY SOUNDARY ADJOINING LEGEND
7 eT ~ VILLA ————
COL STEEL COLUMN
p> N _ DP DOWNPIPE
| ; = TP TIMBER POST
PANTRY 58 wp WASTE PIPE
8
| 1950x1360mm £8 BATHROOM HEATER LIGHT AS SPECIFIED
PLASTERBOARD — 25u
= DP L 823 O EXHAUST FAN AS SPECIFIED
< EXTG. a
| gl (EXTE FL DSO S ° LED DOWNLIGHT AS SPECIFIED
S ° 1
oO
| a KITCHEN a 8 SMOKE DETECTOR TO LOCAL
3035x2275mim- f . | Ca AUTHORITY REQUIREMENTS
PLASTERBOARD Fr Is /
FL 2,560 & 12g \ CEILING FAN AS SPECIFIED
| | , on 8 ° > /
oa |S oa XN
x lg Z -
( 7 3
\ VING/DINING 3 3
fi =
_¢ 6490x3275mm = NOTE:
° PLASTERBOARD, | LIGHTING LAYOUT SHOWN IS NOMINAL.
- 6 | BUILDER TO CONFIRM SUITABLE LAYOUT
- AGAINST ENERGY EFFICIENCY REPORT
7 AND LOCAL AUTHORITY REQUIREMENTS
6 D ECK 4 & ADJOINING AND COORDINATE WITH ELECTRICIAN.
4895x2110mm = 3
BS INSULATED PANEL Ss 5 of SHARED
oO
ADJOINING “Hl so, PHVAREES BOUNDARY yal je ROADWAY
SHARED DP BOUNDARY
(DEDICATED LOT
ROADWAY EXCLUSIVE USE AREA)
CRITICAL NOTE: PARTITION WALLS SHOWN ARE BASED ON 70mm WIDE STUD FOR
APPROVAL PURPOSES ONLY. REFER TO STRUCTURAL ENGINEER'S DETAILS FOR ALL
FRAMING SIZING AND STRUCTURAL REQUIREMENTS THROUGHOUT PROPOSED
WORKS. WHERE 90mm STUD FRAMES ARE REQUIRED TO SUIT PROPOSED
STRUCTURE, BUILDER TO MAINTAIN EXTERNAL BUILDING FOOTPRINT AND ADJUST
(01 RE FLECTE D C EILIN G PLAN - LEVEL 1 ROOM SIZES ACCORDINGLY ON INTERNAL SIDE, ENSURING MINIMUM INTERNAL
- SCALE 1100 CIRCULATION WIDTHS ARE MAINTAINED (WHERE REQUIRED). ALL DIMENSIONS
YT) SHOWN ARE FOR APPROVAL PURPOSES ONLY, STRUCTURAL LAYOUT TO BE
CONFIRMED ON SITE BY PROJECT ENGINEER & BUILDER PRIOR TO CONSTRUCTION.
NOTES: AMENDMENTS PROJECT “DRAWING CREATED SCALE@A3
1 TS ISACOMPUTER GENERATED ORAMING, DONT anENoBY KaNo,| AMENOMENTS ay ;
2 route ANE 10 BF CHECKED ONSITE PRIOR TO CONSTRUCTON ‘A ] 17.08.2023] ISSUE FOR BUILDING APPROVAL GB FOR APPROVAL PROPOSED RESIDENTIAL ALTERATIONS AUG 2023 1:100
3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHIN THE DRAWINGS B | 14.01.2025) PROJECT SCOPE ADJUSTMENTS GB ‘ADDRESS PROLECT NO. REVISION www.gtgroup.net.au
" ARE TO BE REPORTED TO THE DESIGNER PRIOR TO CONSTRUCTION. C |15.01.2025| UPDATED PROJECT SCOPE ADJUSTMENTS, GB 22048 Cc

GT GROUP

2/30 HASTINGS STREET, NOOSA HEADS QLD 4567

DRAWING

REFLECTED CEILING PLAN - LEVEL 1

[email protected]
era Ie
(07) 3298 6938

COPYRIGHT:

© GT GROUP BUILDING DESIGN. THESE DRAWINGS ARE PROTECTED BY
THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED
WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.

| AUTHOR: GB
| ORIGINAL SHEET SIZE: A3 [420x297mm]

DW, NO.

A110

D

 

Used in these records

About this file

File size
10.2 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Change proposal plans.pdf · 10.2 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.