Council archive · source document
Change proposal plans · 51983.3225.22
Plans and drawings: the text below has words only, no drawings.
Very large file (10.2 MB): may take a few minutes to open.
NOTE:
UNLESS NOTED OTHERWISE, ALL EXISTING
LEGEND
NOTE
NOTES
NOTE:
THESE DRAWINGS ARE DESIGN CONCEPTS
BUILT WORKS ARE TO REMAIN. GENERALLY, NGL NATURAL GROUND LINE UNLESS NOTED OTHERWISE, ALL EXISTING 1. ALL CONSTRUCTION WORK UNDERTAKEN ONLY AND SHALL NOT BE USED IN ANY
PROPOSED WORKS ARE TO MATCH EXISTING. BUILT WORKS ARE TO REMAIN. FOR FURTHER IS TO COMPLY WITH THE NATIONAL
WAY FOR STRUCTURAL PURPOSES. REFER
CLARIFICATION ON EXTENT OF DEMOLITION CONSTRUCTION CODE (BCA), RELEVANT -
WORKS, REFER TO PROPOSED FLOOR PLAN FOR AUSTRALIAN STANDARDS AND TO STRUCTURAL ENGINEER'S DETAILS
PROPOSED RECONFIGURATION LAYOUT, WALL APPLICABLE LOCAL AUTHORITY FOR ALL MEMBER SIZES, SPECIFICATIONS
SETOUT DIMENSIONS AND OPENING LOCATIONS. REQUIREMENTS. AND SITE SPECIFIC STRUCTURAL
2. ALL SETBACK/SETOUT DIMENSIONS ARE REQUIREMENTS.
TO BE CHECKED AND VERIFIED ON SITE
PRIOR TO CONSTRUCTION
RIDGE (APPROX. RL 13.325) RIDGE (APPROX. RL 13.325)
af
CEILING +2360n}n41 | r CEILING +2360 tT
+ | + mm
] oH PAINTED FLUSH SET PLASTERBOARD PAINTED FLUSH SET PLASTERBOARD
| oae WALL AND CEILING LINING WALL AND CEILING LINING
LOFT Sire LOFT
Net
| ou
oO
LOFT (RL 1028) ill ALL FRAMING TO STRUCTURAL ENGINEER'S DETAILS
_ Z. ae _ _ = _ | _ _ _ _
Wee H ~¥ z=
CEILING +2560mm ¢ WALL INSULATION TO COMPLY WITH CEILING +2560mm
io ENERGY EFFICIENCY REPORT ALL FRAMING TO STRUCTURAL ENGINEER'S
g
5 ENSUITE 1 WE 600mm WIDE 'HEKA HOOD' OR APPROVED BED2 ft. DETAILS
EQUIVALENT WINDOW AWNINGS x2, BUILDER
LEVEL 2 (RL 7.538 - TO CONFIRM SPECIFIC AWNING DETAILS WITH 3° PITCH Wal INSULATION TO COMPLY WITH
EVEL 2 (RL 7.535) | _ __ CLIENT PRIOR TO CONSTRUCTION __ — SAITCH E Le _ ENERGY EFFICIENCY REPORT -
a vy a
CEILING ¥2560mm CEILING-+2560mm,
tl «+ REFER DOOR AND WINDOW DETAILS INSULATED PANEL ROOF OVER EXISTING
9 JOINERY AS SPECIFIED DECK TO STRUCTURAL ENGINEER'S DETAILS
S KITCHEN PANTR DECK LIVING
[ Lo ‘ MEE CERSTWO ARTO PAINTED PVC DOWNPIPE AS SPECIFIED
LEVEL 1 (L479) r=] Lit ie REPLACE EXISTING
Zz | — — —_ — _ | — _ — _— —_
LING +2700mm ¢___ Wait CLADDING TO MATCH EXISTING EILING +2700mm <—___________ WALL CLADDING TO MATCH EXISTING
So CEILING +2400ehm
3 €< INTERNAL LIFT TO LIFT SUPPLIER'S €< INTERNAL LIFT TO LIFT SUPPLIER'S
8 L
“ CA LIFT, =WC DETAILS CARPORT ENTRY LIFT DETAILS
y | FIXTURES AND FITTINGS AS SPECIFIED < REFER DOOR AND WINDOW DETAILS
GROUND (RL 1.91) LY <e A
ACL (RL 1.91) f ]
REINFORCED CONCRETE GROUND SLABS 7
TO STRUCTURAL ENGINEER'S DETAILS REINFORCED CONCRETE GROUND SLABS
TO STRUCTURAL ENGINEER'S DETAILS
(A DETAIL SECTION A (8 \ DETAIL SECTION B
LT SCALE 1:100 LT) SCALE 1:100
NOTES: AMENDMENTS PROJECT “DRAWING CREATED ‘SCALE @ A3
1 TS ISACOMPUTER GENERATED ORAMING, DONT anENoBY KaNo,| AMENOMENTS ay ;
2 PrOUTS ANE TOBE CHECKED ONSITE PRIOR TO CONSTRUCTION, ‘A | 17.08.2023] ISSUE FOR BUILDING APPROVAL GB FOR APPROVAL PROPOSED RESIDENTIAL ALTERATIONS AUG 2023 1:100
2. ANY DISCREPANCIES OR OMISSIONS FOUND VITHINTHEDRAWNGS | 8 |13.09.2023| UPDATED ISSUE FOR BUILDING APPROVAL ga ADDRESS PROJECT NO, REVISION Mamet Mariel]
4 tonorscamisomnns MORTOOASTHETON. | | 1501 2005| UPDATED PROJECT SCOPE ADJUSTMENTS 8 2/30 HASTINGS STREET, NOOSA HEADS QLD 4567 awe _D GT GROUP Dis RSET ache
COPYRIGHT:
© GT GROUP BUILDING DESIGN. THESE DRAWINGS ARE PROTECTED BY
THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED
WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.
| AUTHOR: GB
| ORIGINAL SHEET SIZE: A3 [420x297mm]
DRAWING
DETAIL SECTIONS A AND B
DW, NO.
A300
Orsay
(07) 3298 6938
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Change proposal plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 10.2 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file