Council archive · source document
Change proposal plans · 51983.3225.22
Plans and drawings: the text below has words only, no drawings.
Very large file (10.2 MB): may take a few minutes to open.
NOTE: DIMENSIONS SHOWN FOR DOORS AND WINDOWS REPRESENT LEGEND NOTES N\ PHYSICAL OPENING SIZES. FRAME MANUFACTURER TO INCREASE FG - FIXED GLAZING. 1. REFER FLOOR PLAN FOR OPENING DIRECTION OF ALL WINDOWS AND DOORS. SIZES OF STUD OPENINGS AS REQUIRED TO SUIT DOOR AND WINDOW 2. DOOR AND WINDOW FRAWING FINISH TO BE CONFIRMED BY CLIENT AND/OR MANUFACTURER'S REQUIREMENTS. 3. FRAME DIMENSIONS SHOWN ARE NOMINAL. DOORS AND WINDOWS TO BE PRICED BASED ON THE CLOSEST STANDARD SIZE TO THAT SHOWN. 4. ALL GLAZING SHALL COMPLY WITH AS1288 5. GLASS THICKNESS SHALL BE DESIGNED BY THE DOOR & WINDOW SUPPLIER TO SUIT LOCAL WIND CONDITIONS. 6. UNLESS NOTED OTHERWISE, ALL GLAZING SHALL BE CLEAR FINISH. 7, ALL OPENABLE DOOR AND WINDOW FRAMES (INCLUDING LOUVRE WINDOWS) ARE TO ALLOW FOR INSTALLATION OF INSECT OR 'CRIMSAFE' SECURITY SCREENING. 8. ALL GLAZING TO COMPLY WITH THE REQUIREMENTS NOTED IN THE SITE SPECIFIC ENERGY EFFICIENCY ASSESSMENT AND REPORT. 9. BUILDER TO ALLOW FOR DOUBLE GLAZED WINDOWS AND DOORS IN CONTRACT (WHERE DESIGN ALLOWS). CONFIRM WITH CLIENT PRIOR TO CONSTRUCTION. 2100 770 ~ gq ° | | | e \ / / z | Cu og | gs S So — Ze 2] f s) (>= | se Ba / \ \] a | oO FFL | vw — — F ~~ F ~~ F a ~~ a ~~ a ~~ a ~~ ALUMINIUM FRAME. TIMBER FRAME. TIMBER FRAME. TIMBER FRAME. 2100 1500 8 hii FG . = a | 47 ie ~~ s 2 3 gS — Ss a s 3 N g 8 8 s FEL = WZ —_ —_ ; —_ —_ —_ ; —_ —_ —_ —_ —_ —_ —_ —_ _ —_ e 8 01 02 031 104 05 NOTE: ALL PROPOSED WINDOWS TO MATCH SN EXISTING. BUILDER TO CONFIRM ON SITE WINDOW ALUMINIUM FRAMED ALUMINIUM FRAMED ALUMINIUM FRAMED ALUMINIUM FRAME AWNING WINDOW FIXED GLASS WINDOW AWNING WINDOW SLIDING WINDOW. TYPES AND SIZES PRIOR TO CONSTRUCTION. (TO BE CONFIRMED). (TO BE CONFIRMED). (TO BE CONFIRMED). NOTES: AMENDMENTS PROJECT “DRAWINGCREATED -- SCALE@A3 1, THISIS A COMPUTER GENERATED DRAWING. DO NOTAMENDBY KAND.| Rey parE DESCRIPTION ay ; » route ANE 10 BF CHECKED ONSITE PRIOR TO CONSTRUCT, ‘A | 17.08.2023] ISSUE FOR BUILDING APPROVAL GB FOR APPROVAL PROPOSED RESIDENTIAL ALTERATIONS AUG 2023 1:50 2. ANY DISCREPANCIES OR OMISSIONS FOUND WITHINTHEDRAWNGS | 8 |13.09.2023| UPDATED ISSUE FOR BUILDING APPROVAL ga ADDRESS PROLECT NO. REVISION Mime etre sareiselt) «Bonorsone BoM NRTPCOASTTON | 1501 2n25| UPDATED PROVECT SCOPE ADWUSTHENTS ce 2/30 HASTINGS STREET, NOOSA HEADS QLD 4567 on oT GROUP RreRGIS eM aaTe COPYRIGHT: [amor ce | rns DWG, NO. 0410 063 172 (© GT GROUP BUILDING DESIGN. THESE DRAWINGS ARE PROTECTED BY THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED [ ORIGINAL SHEET SIZE: A3 [4201297 mm] DOOR AND WINDOW SCHEDULE A400 (07) 3298 6938 WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Change proposal plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 10.2 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.