Performance outcomes                                                           Acceptable outcomes                                                            Comments

Development provides an adequate water supply for fire fighting purpose                                                                                       The dwelling within the southern lot is to install dedicated fire-fighting
which is reliable, safely located and freely accessible.                       OR                                                                             water storage (I.e. swimming pool or water tank) that will be available
                                                                               AO3.2                                                                          solely for fire-fighting purposes. Fittings are to be constructed to
                                                                               Where there is no available reticulated water supply, the premises has:        assure access to relevant fire-fighting vehicles.


                                                                                     a.   an accessible dam, swimming pool or water tank available for
                                                                                          fire fighting purposes with an onsite water volume of not less
                                                                                          than 5,000 litres; and
                                                                                     b.   a water supply outlet pipe 50 millimetres in diameter fitted with
                                                                                          a standard fire brigade fitting connected to the water supply
                                                                                          (other than where the water supply is in a swimming pool or
                                                                                          dam).


Essential Community Infrastructure

PO4                                                                            AO4.1                                                                          Not Applicable

Essential community infrastructure is able to function effectively during      Development involving essential community infrastructure is not located        No facilities are proposed as this stage of the application, thus AO4.1-
and immediately after bushfire events.                                         within a medium or high bushfire hazard area.                                  4.2 is not applicable as it is unknown whether essential community
                                                                                                                                                              infrastructure will be included in the detail design phase.
                                                                               OR

                                                                               AO4.2

                                                                               Where located in a medium or high bushfire hazard area, development
                                                                               involving essential community infrastructure is designed to function
                                                                               effectively during and after a bushfire event in accordance with a Bushfire
                                                                               Hazard Management Plan.


Hazardous Materials

PO5                                                                            AO5                                                                            Not Applicable

Public safety and the environment are not adversely affected by the            Hazardous materials are not manufactured or stored in bulk in a bushfire       The proposed land use on the newly created land parcel does not
impacts of bushfire on hazardous materials manufacturing or storing in         hazard area.                                                                   involve hazardous materials.
bulk.


www.thereforgroup.com.au                                                    24-0565E/BF | Sunshine Butterflies | Bushfire Management Plan | 12.03.2026 | Version 1.0                                                            34
Log in to download the original file

Bushfire Hazard Assessment and Management Plan.pdf · 5.4 MB (large file)