                                                                               APPROVED PLANS
                                                                                132003.221152.6
                                                                                NOOSA COUNCIL
                                                                                 19 JULY 2018



       are to be removed and the roots covered with river sand or other coarse granular fill
       before replacing the soil. Builder’s sand is not to be used, as its high salt content can be
       toxic to roots.
   •   The advice of an Arboriculturist should be sought where underground structures present
       within the TPZ are/will become redundant. In general it is preferable to leave such
       structures in situ and seal them off as this avoids the need for significant excavation.
   •   All works within a TPZ must be supervised by the project Arborist and are to be carried
       out according to the Australian Standard 4970-2009 and as permitted in accordance
       with the prior approval of the Council.


Construction Work Within A TPZ

   •   Prior to installation of a new ground surface, existing ground cover vegetation should be
       killed using an appropriate herbicide e.g. Glyphosate based products. Herbicides that
       can leach through the soil e.g. products containing Sodium Chlorate should not be
       used. Once dead, the vegetation and loose organic matter should be removed from
       the soil surface using hand tools.
   •   If ground levels are to be raised with a TPZ this should be achieved by use of a granular
       material that does not inhibit vertical gaseous diffusion e.g. gap graded fill. Depending
       upon the load bearing capacity of the soil it may be necessary to install a load
       suspension layer such as a cellular confinement system.
   •   Works within the TPZ may be permitted for the construction of approved works such as
       modified footings (e.g. pier and beam, cantilevered slab etc.), designed to minimise
       the impact upon the root system of the tree. Any excavation must be carried out by
       hand and is to avoid damaging the protective bark of any tree roots encountered.
       Should any roots over 25mm diameter be encountered, then the location of the
       modified footing must be adjusted as required to prevent damage to these roots. Roots
       smaller than 25mm diameter may be pruned back using a sharp saw or secateurs.
       Where appropriate the project Arborist may be required to supervise excavations and
       consult with the project Engineer as to the relocation of modified footings etc.
   •   Works within the TPZ may be permitted for the construction of above grade slabs and
       pavements, designed to minimise the impact upon the root system of the tree. In
       concentration carbon dioxide is detrimental to tree root function. Because this gas
       principally diffuses vertically through the soil, new impermeable surfacing within a TPZ
       should where possible be restricted to a maximum width of 3m and situated tangentially
       to one side of a tree only, or confined to an area no greater that 10% of the TPZ.
   •   All works within a TPZ must be supervised by the project Arborist and are to be carried
       out according to the Australian Standard 4970-2009 and as permitted in accordance
       with the prior approval of the Council.




12 PARK ROAD         1A / 357 – 359 Cleveland Street, Redfern, NSW, 2016 | PH +61 2 9699 2622         13

NOOSA HEADS          [email protected] | www.mylesbaldwin.com | ABN 68 139 176 328
Log in to download the original file

132003 221152 6 - Approved Plans.pdf · 4.6 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.