Attached to the e-mail Development Application - Geotech report & Sunshine Butterflies flyer 2 of 2 MCU16/0090.
OUR BACKYARD
468 MCKINNON DRIVE, COOROIBAH
It can be seen in Figure 8 that there is sufficient room to position the wastewater land application area in
accordance with the siting requirements of Noosa Council, including being located on land not subjected to
flooding (at least immunity to 1 in 100 year event), 2 m and 4 m setbacks from side and lower boundaries, and
a 50 m setback from the existing dam.
Dam
Suggested septic
tank location
3 x 20 m long
absorption beds
Text Figure 8: Proposed septic tank and absorption bed layout
7.3.2 System Positioning
Siting of the land application systems should generally be in accordance with the horizontal and vertical
setback distances recommended in Table R1 of AS1547:2012, as summarised in Table 3.
Table 3: Horizontal and Vertical Setback Distances for Irrigation Areas
Site Feature Range Primary Effluent Secondary Effluent
Horizontal Setback Distance
Property boundaries 1.5 m to 50 m 2 m to 4 m 2 m to 4 m
Buildings/houses 2 m to >6 m 10 m 10 m
Surface Water 15 m to 100 m 50 m 15 m to 30 m
Bore, well 15 m to 50 m 50 m 30 m
Recreation areas (children’s play
3 m to 15 m 15 m 6m
areas, swimming pools, etc.)
In-ground water tank 4 m to 15 m 15 m 10 m
Vertical Setback Distance
Groundwater or hardpan 0.6m to >1.5m 1.2 m 0.6 m
4 May 2016
Report No. 16081-001-Rev0 10