Specific Outcomes                          Probable Solutions                          Proposal
                                           vertical articulation, break up building
                                           bulk and create interest and shadow
                                           lines. Awnings create interest and the
                                           roof profile aims to reduce building bulk
                                           by sloping to perimeter gutters).

O33 Buildings give the physical            S33.1 No solution provided                  Conflict with specific outcome –
appearance of being one Detached                                                       please refer to section 7.8 of the
house.                                                                                 development Assessment Report.

O34 Buildings and structures are           S34.1 No solution provided                  Not applicable – the site does not
designed to address any waterfront                                                     adjoin a watercourse.
aspect and to contribute positively to
the waterfront character.
Garages and carports                       S35.1 Garages and carports—                 Not applicable – no garages or
O35 Garages and carports are designed      a) have a front boundary setback of at      carports are proposed. Basement level
and sited to visually integrate with the   least 6m; and                               and ground level parking is proposed.
building and avoid dominating the          b) adopt a roof form and building style
street.                                    similar to that of the building; and
                                           c) present a minimum width to the
                                           streetscape (the total width of garage
                                           doors is no more than 6m or 50% of
                                           the frontage width, whichever is the
                                           lesser, where the structure faces the
                                           street); or
                                           d) that are visible from, but do not face
                                           the street, include windows or other
                                           articulation and have a 6m landscaped
                                           buffer between the structure and the
                                           road frontage.
Setbacks to watercourses of Noosa          S36.1 For lots adjacent to the              Not applicable – the site is not located
Waters Estate                              watercourses of Noosa Waters Estate,        adjacent to the watercourses of Noosa
O36 Buildings works, filling or            building works, filling or excavation       Waters Estate.
excavation works and improvements for      works       and      improvements     are
lots adjacent to the watercourses of the   undertaken no closer than 4.5m from
Noosa Waters Estate are appropriately      the centreline of the concrete revetment
designed and sited to ensure that—         wall.
a) the flood storage capacity of the
watercourse is not affected;
b) no additional load is placed on the
revetment walls;
c) the membrane adjoining the
revetment wall is not affected;
d) the amenity of surrounding
development is maintained; and
e) views from the watercourses and
public open space are not obscured.


BUSINESS USES CODE
Table 14-8 for all Business Uses

Specific Outcomes                          Probable Solutions                          Proposal
14.13 Effects of use
Electricity infrastructure                 S18.1 No solution provided                  Complies - The proposal does not
O18 The development does not                                                           adversely impact on existing or future
adversely impact on existing or future                                                 electricity supply infrastructure
electricity supply infrastructure;
AND                                        S19.1 Development for uses adjacent to      Not applicable - Site is not within 50m
O19 All uses and works maintain an         or within 50m of an existing electricity    of an electricity substation.
adequate safe distance from electrical     substation        incorporates      noise
infrastructure including substations,      attenuation measures to mitigate noise
overhead powerlines, power poles and       impacts;
transformers.                              AND
                                           S19.2      Buildings    and    structures   Complies - The proposal will not be
                                           (including swimming pools, sheds, tennis    constructed under overhead electricity
                                           courts and outbuildings) are not            lines or within electricity easements.
                                           constructed under overhead electricity

Used in these records

About this file

File size
1.6 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Development Assessment Report.pdf · 1.6 MB (small file)