NOTES:
80 PERCENT ENERGY EFFICIENT GLOBES TO
ALL FIXED INTERNAL LIGHTING.
MINIMUM 4 STAR 'MEPS' RATED AIR
CONDITIONERS WHERE FITTED,
SYMBOLS ARE INDICATIVE ONLY. EXACT
MODEL TO BUILDER'S SPECS.
MECHANICAL VENTILATION TO BE IN
ACCORD. WITH THE BCA PART 3.8.5 & AS
1668.2
LEGEND:
DW DISHWASHER
PH PHONE
TV TELEVISION
FR FRIDGE
RH = RANGEHOOD
EX EXTERNAL
A/C AIR CONDITIONER
HW HOTWATER
MH MANHOLE
1:100
ELECTRICAL PLAN
ELECTRICAL LEGEND:
SYMBOL
DESCRIPTION
SWITCHBOARD/METER BOX
DISTRIBUTION BOARD
SINGLE POWER POINT - 300 above FFL
DOUBLE POWER POINT - 300 above FFL
SINGLE POWER POINT - 1200 above FFL (UNO)
DOUBLE POWER POINT - 1200 above FFL UNO}
WEATHERPROOF POWER POINT
FLUORESCENT CEILING BATTEN
LED LIGHT FITTING (ROUND)
LED LIGHT FITTING (SQUARE)
FEATURE PENDANT
WALL MOUNTED LIGHT FITTING.
eto | eo BD
RECESSED DOWN LIGHT
LIGHT FITTING - FEATURE RAIL
LUGHT SWITCH - 1000 above FFL (UNO)
LIGHT SWITCH WITH DIMMER CONTROL
2-WAY LIGHT SWITCH
BA
ISOLATION SW. FOR HARD WIRED FIXTURE
+S
=x
TELEPHONE POINT
TELEVISION POINT
5 {4
| =
¢
CEILING FAN - @1200mm - MINIMUM
\
7
,
x
CEILING FAN - 21200mm - MINIMUM
WITH FLUORESCENT LIGHT
SMOKE ALARM - HARD WIRED
AIR CONDITIONER UNIT
HOT WATER UNIT (storage)
HOT WATER UNIT (gas)
|
izi@Re
|
WIRING
FAN, LIGHT COMBINATION
FAN, HEAT, LIGHT COMBINATION
LIGHT SENSOR
ITEM
N
XN
DOWNLIGHTS - INTERNAL - LED.
DOWNLIGHTS - EXTERNAL - LED
FLOURO BATTENS - INTERNAL
FLOURO BATTENS - EXTERNAL
LED LIGHT FITTING - SQUARE/ROUND
elolol—|ny
FEATURE PENDANTS
FAN LIGHTS
FAN HEAT LIGHTS
WALL LIGHTS - INTERNAL
WALL LIGHTS - EXTERNAL
SENSORS
POWER POINTS - SINGLE - INTERNAL.
rey
POWER POINTS - DOUBLE - INTERNAL
POWER POINTS - SINGLE - EXTERNAL
POWER POINTS - DOUBLE - EXTERNAL
SMOKE ALARMS
TELEPHONE POINTS
TELEVISION POINTS
CEILING FANS
CEILING FANS WITH LIGHT
Glolalr|/—-|elalo}—|ulololo|—jo
DOWN LIGHT - H20 PROOF
GJ. Gardner. Hones
Sunshine Coast North
2/171 Noosa Eumundi Rd PH: 07 54 702324
Noosaville , Qld.
THESE DRAWINGS AND DESIGN ARE
COPYRIGHT AND WILL NOT BE USED
"OR REPRODUCED BY ANY MEANS,
~ WHOLLY OR PARTLY WITHOUT PRIOR
WRITTEN PERMISSION FROM -
GJ GARDNER HOMES
DATE
RW)
ICHED|
COMMENTS
17/10/2018
AK
RW
PRELIMINARY PLANS
DNB
AK
RW
RELOCATED, WIDTH REDUCED, EAVES ADDED
25/10/2018
AK
RW
GENERAL AMENDMENTS
DO_NOT SCALE FROM THIS DRAWING
VERIFY ALL DIMENSIONS PRIOR TO
COMMENCEMENT OF ANY SITE WORKS
AND REFER ANY DISCREPANCIES TO
BESPOKE BUILDING DESIGN
12/11/2018}
AK
RW
GENERAL AMENDMENTS
PROJECT
PROPOSED RESIDENCE
CUSTOM
JOB SPECIFICATION BY BUILDER TAKES
PRECEDENCE OVER THESE PLANS
DATE
ELECTRICAL PLAN
Ye
SALES CHRIS McNEIL
PROJECT STATUS
CONSTRUCTION DRAWINGS
13/11/2018)
AK
RW
DRAFT CONSTRUCTION DRAWINGS
1/0219)
AK
RW
AMENDED CONSTRUCTION DRAWINGS
CLIENT
ERHARTER, Robert
LOCATION
LOT 6 ON RP82318
10 OPAL LANE
COOROY, QLD
SCALE HEET SIZE] CLASS WIND ISSUE
INDICATED, AS la E
DRAWING FILE NUMBER PAGE
GJGSCN190173 Supp-1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLarge file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.