Original source · versioned page text
Approved Plans - MCU21/0221
Plans and drawings
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn Plate 8: Flamesol Modelling
Table 1. Radiant Heat Flux Minimum Setbacks to secure <29kW/m²
Vegetation Description <29 kW/m² Minimum Setback
VHC 8.1 – Wet Eucalypt Tall Open Forest 25.3m
As per Table 2, it is recommended that the proposed new dwelling shall be provided with a dedicated
Asset Protection Zone (APZ) with a width of 26m from the adjacent High Potential Intensity Area
associated with the VHC 8.1 vegetation surrounding the dwelling. This setback would also provide a BAL
29 construction standard to the proposed dwelling under AS3959:2018. Section 4.2 prescribes the specific
management requirements of the APZ.
The new dwelling is proposed approximately 10m from the eastern allotment boundary and 20m from
the southern boundary. It is noted that a 26m setback is not available to be provided within the extent of
the allotment boundary to the south and east. This is considered acceptable as the boundaries adjoin
October 2021 BUSHFIRE HAZARD ASSESSMENT Page: 15
797 Ringtail Creek Road, Pomona
Document Set ID: 21731677
Version: 1, Version Date: 14/12/2021
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.