r . Project No. 306-2474
November, 2006 Page 6
eee IE
* Imported select fill material, if required, should be a good quality select fill material
with a soaked CBR >10% and a maximum aggregate size of 75mm.
* Fill placed in the area of the building should be compacted in layers (approximately
200mm loose thickness) to a density not less than 95% of maximum dry density in
accordance with AS 1289 5.1.1 (Standard Compaction).
* Field density testing should be carried out to check the standard of compaction
achieved and the placement moisture content. The frequency and extent of testing
should be as per guidelines in AS.3798-1996, Section 8.0.
The soils encountered on site {to borehole depth) should be within the excavation limits
of a small dozer (eg. Cat D4 or similar) in bulk earthworks and a medium sized backhoe
(eg. Case 580 or similar) in trench excavations.
© 6.3 Excavation Stability
The following general recommendations are made for short term stability of batters for
bulk excavation of the site.
* Batter angle not greater than 1V:2.5H above the horizontal.
* Top of batter to be a minimum of 2.0m inside any boundary line, in addition to 3.0
metres distance from any building or structure.
* If batters are to be left untreated for any length of time, a batter angle of 1V:4H is
recommended and berm width are to be strictly maintained.
6.4 Building [email protected]. Site Classification
While a site classification in accordance with AS.2870 ‘Residential Slabs and Footings'
relates to residential type construction and is not directly applicable for this development,
itis, however, a valuable method of classification.
Given the investigation drilling encountered Sandy soils only, which are non-reactive to
variations in soil moisture, the site could be classified as “Type A” in accordance with
AS.2870 ‘Residential Slabs and Footings’. While no surface movement would be
expected due to changes in moisture, some settlements may occur in the upper very
loose to loose sand due to vibration induced compaction (construction activities, vehicle
movements, etc.).
TT eee
YF SOIL SURVEYS ENGINEERINGSee the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
0015584F.001.pdfRelated documentPublic source context ↗
07/0528 - Op Works, Landscaping,Access Car Parking & Earthworks - Goode Family Trust [As Published]Related documentApplication case desk ↗
About this file
- File size
- 4.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.