                                                                                                        MCU16/0098


                              Driveways
                      47.     Driveway crossovers must be designed and constructed generally in accordance
                              with the approved plans and in accordance with IPWEA standard drawing RS- 051
                              and must have levels and grades match the levels and the grades of the existing
                              concrete footpath without posing trip hazard.
                      48.     The following must be complied with during the construction of the required
                              crossovers/driveways:
                              a.       The driveway width must not exceed 6m at the front boundary line and 13m
                                       at the kerb line.
                              b.       The driveway surfacing must consist of either an approved hot mixed
                                       asphaltic concrete or patterned/plain concrete and must have a slip resistant
                                       surface.
                              c.       The driveway must be constructed so as not to concentrate stormwater
                                       runoff or ponding onto other properties and/or the road verge.
                              d.       For public safety, the finish levels of crossover must ensure smooth transition
                                       to existing surfaces such as the road grassed verge and existing concrete
                                       pathway.
                              e.       Where applicable, underground service conduits for water supply, electricity
                                       and any other services must be provided as part of the access driveway
                                       works.
                              f.       Have a minimum clearance of 1.0m from any existing power poles,
                                       streetlights or other signage.
                              g.       Have a minimum clearance of 500mm from any Unitywater/Telstra asset,
                                       unless a written approval is obtained from Unitywater/Telstra and submitted
                                       to Council.
                              Pavement Design and Construction
                      49.     Pavement design for privately owned works must be undertaken in accordance
                              with the relevant standards and be designed and constructed to comply with the
                              Disability Discrimination Act (DDA), Access to Premises Standard and relevant
                              sections of AS1428 Design for access and mobility. Structural integrity of the
                              driveway and car park areas will remain the responsibility of the property
                              owner/developer and must be certified by an RPEQ.
                              Works within Road Reserve and Reinstatement Works
                      50.     Safe pedestrian access on all streets in the vicinity of the development must be
                              maintained at all times. Should footpath/road closures be necessary to carry out
                              construction works, Council’s Engineering Officer must be notified prior to the
                              proposed closure and all requirements complied with.
                      51.     Where required, any reinstated road pavement must be in accordance with IPWEA
                              standard drawing RS-170 with road pavement resurfacing to consist of a minimum
                              depth of 50mm of an approved hot mixed asphaltic concrete.




                                                                                                              Page 9 of 18


Document Set ID: 20204040
Version: 1, Version Date: 22/11/2016                                                                Print Date: 22 November 2016, 1:58 PM
Log in to download the original file

Decison package_Noosa Chocolate Factory.pdf · 3.9 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.