Request for Further Information - 010.2008.00000831.001 [As Published] · 142008.831
-2-
4. The Plant Schedule does not include details on the three Pandanus Pedunculatus species,
which are proposed in the front setback on the landscaping plans.
5. Archontophoenix cunninghamiana species and Poa labillardieri species are not native, and
therefore not supported.
6. Provide details of landscaping proposed under the stairwells of the buildings.
7. The Landscaping Plan is required to illustrate the location of bicycle racks at ground floor
level.
8. Demonstrate how disabled access will be provided between the ground floor and upper floor
levels of the building, and between the differing levels of the ground floor.
9. Demonstrate that a maximum of 18 car parking spaces have been designated for staff parking
in accordance with Condition 23.1.1.1 of the Material Change of Use approval (2006/2689).
The current proposal shows 19 spaces for staff parking.
10. Demonstrate that a minimum of 29 car parking spaces have been designated for customer
parking in accordance with Condition 23.1.1.2 of the Material Change of Use approval
(2006/2689). The current proposal shows 28 spaces for customer parking.
Environmental Health
11. Demonstrate that sufficient space has been provided within the development for bin storage
(waste and recycling for 18 tenancies) and bin wash down area in accordance with Council’s
policy, and Condition 66 of the MCU approval (2006/2689). Note, that the current location of
the bin storage area is unacceptable due to the loss of landscaping opportunities in this
location.
12. Provide a Waste Management Plan in accordance with Condition 68 of the MCU approval
(2006/2689).
Land Development
13. Please note that the Security Bond referred to in Condition 13 of the MCU approval
(2006/2689) must be received by Council before a Development Permit for Operational Works
can be issued.
14. Please note that the Proof of Title (re: lot amalgamation) referred to in Condition 17 of the
MCU approval (2006/2689) must be received by Council before a Development Permit for
Operational Works can be issued.
15. With regard to Condition 18 of the MCU approval (2006/2689) please show on the appropriate
drawings, the “Existing concrete footpath and access” on the David Low Way frontage of
the development site. It is noted that the “Crossover-Commercial 4000 wide” shown on Drg
M3087-C04-A can be deleted as it has now been constructed.
16. Please provide a plan showing appropriate sight lines as requested in Condition 20 of the
MCU approval (2006/2689).
17. With regard to Condition 23.2 of the MCU approval (2006/2689) please provide additional
information on the headroom that is expected to be available within the basement especially in
those areas affected by supporting beams and mechanical ducting.
18. Please indicate on the relevant plans the traffic control and directional features as described in
Condition 26 of the MCU approval (2006/2689).
19. Please show the new kerb turnout at the northern end of the development site, together with
Council’s new stormwater infrastructure. The development’s proposed stormwater design
shown on drawing M3087-C05-A should be amended to suit that new work. Please also
confirm that the proposed stormwater drainage design does not conflict with Council’s
existing infrastructure, particularly sewer mains, by showing those services on the
longitudinal section on drawing M3087-C06 A.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Request for Further Information - 010.2008.00000831.001 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 18 KB (small file)
- File type
No other editions are linked here.