Performance outcome                      Acceptable outcome                   Applicant response   Assessment
                                         with the water over
                                         which it is
                                         constructed at all
                                         times and tilts no
                                         more than 15º at
                                         any time;
                                         (b) if a relevant planning scheme
                                         standard is more stringent
                                         than the standard mentioned
                                         in paragraph (a)—the
                                         relevant planning scheme
                                         standard, to the extent it is
                                         more stringent than the
                                         standard mentioned in
                                         paragraph (a).
18.4 Prescribed tidal works that are a   The design and construction of the   Not applicable.      The Project is not a pontoon
pontoon are designed and                 pontoon is consistent with the       Not a pontoon.       therefore PO18.4 is not applicable.
constructed in a way to ensure           following standards—
the pontoon’s flotation unit             (a) subject to paragraph (c), the
will—                                    pontoon’s flotation unit is—
(a) rise and fall to allow for a         (i) attached, through the
change in tidal water levels,            pontoon’s system for
including a change caused                mooring the unit, to
by a flood or storm tide;                concrete anchors in the
and                                      bank landward of the
(b) not be separated from the            pontoon; or
lot to which the pontoon is              (ii) moored by piles;
connected because of—                    (b) subject to paragraph (c), if a
(i) a change in tidal water              tidal water level change
levels mentioned in                      resulting from a flood or
paragraph (a); or                        storm tide with an AEP of 1%
(ii) the flow of tidal water             would cause a pontoon’s
Log in to download the original file

2022-05-16 GC Agenda - Item 7 - Attachment 1 - Report from Marine Approval Specialists(PDF, 3MB).pdf · 3.1 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.