Park Contribution
41. A Park contribution of $3,840 towards the acquisition of additional parkland or the improvement of
existing parkland and facilities in the locality shall be paid to the Council prior to obtaining a
Development Permit for Operational Works in accordance with Council’s Planning Scheme Policy
PSP24 Park Requirements for Development Applications. This amount will be subject to variations
in the Consumer Price Index, All Groups Brisbane from December 2005 until the date of payment.
Frontage Works
42. Footpath improvements will be required to the frontage of the site wherever damage occurs as a
result of developing the site. This may take the form of topsoiling, grassing, and tree planting as
well as replacing any sections of the existing concrete pathway or kerb & channel if damaged.
43. All paths shall be designed and constructed to ensure pedestrian safety using non-slip materials
and to produce an evenly graded surface finish.
44. Any redundant vehicular crossings to the site shall be removed and replaced by kerb & channel,
footpath paving and landscaping such as trees and grasses in accordance with Council’s Standard
specifications prior to commencement of the use permitted by this permit.
Pathway Contribution
45. A pathway contribution of $864 towards external major pathways, in accordance with Planning
Scheme Policy PSP41 Pathway Trunk Network Contributions, shall be paid to the Council prior to
obtaining a Development Permit for Operational Works. This amount will be subject to variations in
the Consumer Price Index, All Groups Brisbane from December 2005 until the date of payment.
Stormwater Drainage
46. All stormwater drainage shall be collected on site and discharged so there is no net increase in
stormwater runoff from the site. Stormwater drainage permitted to drain from the site shall be
discharged to Council’s existing drainage structures. Plans of the drainage design shall be
prepared by a Registered Professional Civil Engineer and submitted to Council prior to obtaining a
Development Permit for Operational Works.
47. The method of collecting and discharging stormwater runoff as indicated on the Stormwater
Concept Plan 05251/H2/A, dated July 2005, by Dryhurst Halstead Stuart Architects is generally
considered acceptable. That is:
47.1. To drain the front carparking area (4 car park spaces and manoeuvring area plus part of the
main driveway) into Eumundi Noosa Road via a Gross Pollutant Trap (GPT), and
47.2. To provide 5 x 10,000 litre underground Precast Concrete Rainwater Tanks at the rear of
the site to store rainwater for use in the landscaped areas and in the nursery areas
distributed via a pressure pump and filter system, and
47.3. To provide overflow capacity from the Tanks via 100 ag-drains into 4 x 12.5m long 600mm
x 600mm infiltration trenches lined with gravel.
48. To minimise the risk of this rainwater storage and infiltration system failing and causing flooding to
downstream properties, overflow pipes shall also be installed from the trenches directly into the
existing stormwater pit in the north-west corner of Lot 80 on SP138388 (within the property to the
east and directly behind the proposed trenches). This will allow excess water to discharge from
the site when the trenches are full, or the ground is fully saturated.
49. To ensure that polluted run-off does not enter Council’s stormwater drainage system, stormwater
run-off from the carparking areas and the driveways shall have the first flush (the first 12 mm of
rainfall or hose-down) collected in a grease/oil arrestor (or similar device) provided on site prior to
being permitted to discharge from the site.
Though a GPT is noted as being proposed towards the frontage of the development, a grease/oil
arrestor or similar device will also be required at the rear of the site to collect run-off from the
carparking and loading bay areas. All other clean stormwater, such as roof water, can bypass the
GTP and grease/oil arrestors.
A detailed maintenance plan shall be prepared for the proposed GPT and/or grease/oil arrestors,
which shall be submitted to the Council for approval prior to obtaining a Development Permit for
Operational Works.
ab c:\docume~1\abecker\locals~1\temp\bcl technologies\easypdf 5\@bcl@5c0dc6aa\@[email protected]
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
SUPERSEDED - 05/1021 - COMPILED Decision Notice [As Published]Related documentApplication case desk ↗
About this file
- File size
- 76 KB (small file)
- File type
No other editions are linked here.