Original source · versioned page text
Attachment 5 - Bushfire Hazard Assessment & Management Plan
Plans and drawings: the text below has words only, no drawings.
Very large file (11.4 MB): may take a few minutes to open.
Original PDF page 35, section 1. The text section number identifies this passage in the reader.
Bushfire Hazard Assessment & Management Plan v1 NCES REF: J000542 Lot 9 on RP225312 – 100 Cooyar Street, Noosa Heads PERFORMANCE OUTCOMES ACCEPTABLE OUTCOMES PROPOSED SOLUTION AO6.5 Where an emergency access point is required, it complies with the relevant works codes and PSP6 Engineering Design Standards. Lot design PO7 AO7 AO7 – N/A – No residential lots proposed. Lot design and building siting minimises bushfire hazard Each residential lot: risk to people and property. a) includes a building envelope, identified on a plan of subdivision; b) is of sufficient size and shape to allow for efficient emergency access to buildings for firefighting appliances (e.g. by avoiding battle- axe/hatchet lots and long narrow lots with long access driveways to buildings); c) where more than 2500m², achieves setbacks from hazardous vegetation in line with Bushfire Attack Level 29 requirements as per AS3959; and d) is designed so that buildings and structures are sited in locations of lowest hazard within the lot and elements of the development least susceptible to fire are closest to the fire hazard. Firebreaks and fire access tracks PO8 AO8.1 AO8.1 – The development does not involves the creation of a new road and Firebreaks and fire access tracks provide: Where development involves the creation of a new road and lots, a lots. firebreak is provided by providing a cleared road reserve not less than 20 metres wide and maximum gradient of 12.5% around the perimeter a) adequate access for firefighting and other of the subdivision, between the created lots and surrounding emergency vehicles; and vegetated lands. b) adequate access for the evacuation of residents and OR emergency personnel in an emergency situation. AO8.2 AO8.2 - The development does not involves the creation of a new road and Fire access tracks are provided between the created lots and lots. surrounding vegetated land that: a) have a cleared minimum width of 6 metres; b) have a maximum gradient of 12.5%; c) provide unbroken access for fire fighting vehicles; d) provide passing bays and turning areas; e) are located within an access easement that is granted in favour of Noosa Council and the Queensland Fire and Rescue Service. AO8.3 AO8.3 – All bushfire management measures would be carried out on the Bushfire management measures are carried out on the subject subject property noting an existing Infrastructure Agreement has been property and not any adjoining property. approved allowing Ozcare to maintain the fire break in the adjacent NSC land. © 2022 34
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.