c. demonstrate how service vehicles will access all proposed VW/arehouses and
manoeuvre the site.

Swept paths demonstrate the ability of an SRV to access the proposed loading bays of
Warehouses 1-8 and circulate the site.

d. all parking facilities must be designed in accordance with AS2890; and

All parking facilities accord with the minimum dimension as stipulated within AS2890.1
and a swept path assessment has been undertaken which demonstrates suitable
accessibility to critical spaces.

e. provide additional detail to demonstrate that pedestrian foot-traffic and vehicles
will be provided with a safe environment on the access driveways/ramps.

The proposed accessway is a shared accessway between the vehicle and pedestrians. All
accessways are designed in excess of the minimum dimensions for two-way accessways
with at least 6.0 metres in width which is sufficient to cater for shared use by both vehicle
traffic and pedestrians.

7. Provide a minimum of 35 freely accessible car parking spaces, and 10 bicycles
spaces.

Item - Car Parking demand

In accordance with Table 9.4.1.4 the development incurs the assumed demand of 10
bicycle spaces.

Information Required
8. Provide revised plan identifying an area for parking of bicycles.

The revised plans show a total of 31 tenancies inclusive of warehouses, micro warehouses
and trade hubs. A total of 32 car parking spaces have been provided, meeting the
statutory requirement of 32 car parking spaces. A total of 18 bicycle parking spaces have
also been provided.

Waste Management
Item - Waste Removal

Council’s waste department does not support the removal of waste by a private
contractor such as Bin Boss to be a means of waste disposal. It is expected that
developments will use Council’s contractor for waste removal. For a development of
this size the servicing of waste bins on the street is not feasible therefore on site
servicing is required through a proper bin storage compound. The use of bulk bins is
recommended.

These can be collected from defined waste storage locations on site. Internal waste
storage is not recommended. It is worth noting warehouses generally produce a high
litreage of cardboard and general recycling bins would not be sufficient for this bulk
bins <1100L allow access to our cardboard service.

Information Required

12. Swept paths shown are to the specifications of a SRV vehicle and not to council
collection vehicle specification. Proper swept paths must be provided to allow the
collection vehicle to either drive through or have safe turnaround as per the vehicle
specifications in the Noosa Plan. If 240/360L bins are required it will be to Side Lift
Collection Specs. If 1100L bins are required it will be to Rear Lift Vehicle Specs
(Smallest Truck). If 1.5m3 or greater are required it will be to Front Lift Specs (Largest
Truck).

20755T-LETO2-F01 P6

newoo'o!es
Log in to download the original file

Reference Document MCU23-0145 - Vehicle Access and Car Parking Requirement.pdf · 11.3 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.