SAFETY IN DESIGN HAZARD REPORT

                                                      App?                                                                                                                     Action
                  Consideration                                           Hazard / Comment                               Controlling Action                 Action By
                                                                                                                                                                             Status
                                                                                                            is provided to retaining walls over 1m in     /Landscape
                                                                                                            height                                        Architect
                                                                                                            Safety fences to be provided where hazard
                                                                                                            exists as per Operational Works Design
                                                                                                            Drawings
 Work is on a telecommunication tower                   
 Involves demolition of an element of a
 structure that is load-bearing or otherwise            
 related to the physical integrity of the structure
 Involves, or is likely to involve, the disturbance
 of asbestos                                            
 Involves structural alterations or repairs that
 require temporary support to prevent collapse          
 In or near a confined space                                    Structures and manholes                     Undertake works in accordance to Council      Designer /        Ongoing
                                                                                                            standards. Construction procedures to be      Contractor
                                                                                                           undertaken in accordance with WH&S
                                                                                                            requirements.
 In or near a shaft or trench with an excavated                 Excavation depths are anticipated to        Undertake work in accordance to Council       Designer/         Ongoing
 depth greater than 1.5m or is carried out in or                exceed 1.5m                                 standards. Construction procedures to be
 near a tunnel                                                                                             undertaken in accordance with WH&S
                                                                                                                                                          Contractor

                                                                                                            requirements.
 Involves the use of explosives                         
 Is carried out in or near                              
          Pressurised gas distribution mains or
           piping                                       
          Chemical, fuel or refrigerant lines          
          Energised electrical installations or
           services                                     
 Involves tilt-up or precast concrete                           Precast stormwater manholes                 All works to be undertaken in accordance      Contractor        During
                                                                                                           with WH&S requirements including work                           Construction
                                                                                                            method statements



Document: QAF2024 Safety in Design Hazard Report – Generic
Revision 10 – 10/02/2015                                                                                                                                                    Page 4 of 12
File: H:\B14\150-199\B14158.W\01 Final Layout Op Works\Checklists\B14158.W - Safety in Design_WQCP.docx [Update to show User's file]                    Calibre Consulting (Aust) Pty Ltd
Log in to download the original file

16-001014-02A (Ultimate SCMMP).pdf · 14.7 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.