SAFETY IN DESIGN HAZARD REPORT

                                                      App?                                                                                                                          Action
                  Consideration                                           Hazard / Comment                               Controlling Action                      Action By
                                                                                                                                                                                  Status

 On, in or adjacent to a road, railway, shipping                Potential injury or death to existing       Engineering plans refer to provision of            Contractor        During
 lane or other traffic corridor that is in use by               road users as the result of construction    adequate traffic control by the contractor as                        Construction
 traffic other than pedestrians                                 works                                       a part of the operational works in
                                                                                                           accordance with WH&S requirements. This
                                                                                                            may also include interim fencing for the site
                                                                                                            including signage
 In an area at a workplace in which there is any                All hazards associated with plant           All works to be undertaken in accordance           Contractor        During
 movement of powered mobile plant                               operations applies                          with WH&S requirements including work                                Construction
                                                                                                           method statements for operation of plant as
                                                                                                            required and site inductions for all visitors
 In an area in which there are artificial
 extremes of temperature                                
 In or near water or other liquid that involves a               Project involves construction of a small    Appropriate safety fencing and warnings            Contractor        During
 risk of drowning                                               pond. This may pose a potential             signs to be erected during construction.                             Construction
                                                                drowning risk.                              Area to be avoid during periods of rainfall.

                                                                                                            The following safety measures have been            Designer          Complete on
                                                                                                            incorporated into the basin design                                   plans

                                                                                                               Thick planting and safety bench around
                                                                                                                the perimeter of the pond to discourage
                                                                                                                entry into pond

                                                                                                               Retaining walls over 1m are to be
                                                                                                               fenced. Maximum height is 2.1m.

                                                                                                               There are multiple points around the
                                                                                                                basin with batter slopes flatter than 1 in
                                                                                                                5 to enable easy access out of the basin
                                                                                                                area

                                                                                                               1 in 6 access track provided at the
                                                                                                                downstream end of the basin
                                                                                                            Therefore access to the water edge is
                                                                                                            limited and the water edge is densely
                                                                                                            planted on a safety bench. No edge of water
                                                                                                            fencing is required.


Document: QAF2024 Safety in Design Hazard Report – Generic
Revision 10 – 10/02/2015                                                                                                                                                         Page 5 of 12
File: H:\B14\150-199\B14158.W\01 Final Layout Op Works\Checklists\B14158.W - Safety in Design_WQCP.docx [Update to show User's file]                         Calibre Consulting (Aust) Pty Ltd
Log in to download the original file

16-001014-02A (Ultimate SCMMP).pdf · 14.7 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.