Appendix D - Traffic Engineering Report · MCU23/0070
Reduced flares measuring approximately 1.0m x 1.0m are proposed on each side of the driveway. These have been considered as part of the swept path analysis which shows these are sufficient to facilitate the right-in/right-out movements for vehicles at the driveway to/from Douglas Lane. Sight Distance The default speed limit of Douglas Lane (being unsigned) is 50km/h under Queensland Road rules, thus requiring 45-69m sight distance. The available sight distance from the vehicular access looking west (in the direction of conflicting vehicles on Douglas Lane) is approximately 35m. Further sight distance is restricted due to the bend in the road and existing bushes/fencing on the edge of the road reserve. Whilst this available sight distance falls below the standard requirements, it is recognised that vehicles travelling on Douglas Lane will be doing so at much less than 50km/h. As a laneway type of road, and given the constrained width and geometry, it is expected that vehicles would be travelling no more than 30km/h (and more practically closer to 10-20km/h). When extrapolating data from the minimum sight distance requirements outlined in AS2890.1, the following would be applicable for a design speed of 30km/h: • Desirable (5 second gap): 42m • Minimum SSD: 23m Therefore, the available sight distance of 35m would be sufficient for this maximum practical speed of vehicles likely to be using Douglas Lane. Due to the fact that Douglas Lane has no verge on the southern side, to ensure that this 35m sight distance is achieved from the observation point of a vehicle exiting the site, it is recommended that all landscaping on west side of the driveway is limited to maximum 0.6m high. This zone of reduced landscaping height is shown in the development plans. Driveway Sight Splay Further to the above discussion regarding vehicle sight distance, the zone adjacent to the exit side of the driveway being provided only with low height landscaping will ensure a driveway sight splay (for pedestrian visibility purposes) is also provided. Notwithstanding, it is noted that this sight splay provision is typically required to allow intervisibility between drivers exiting a car park and pedestrians on a footpath about to cross the driveway. In this instance, as there is no footpath along the frontage of the site and any pedestrians will typically be walking on Douglas Lane itself, arguably the sight splay requirement under AS2890.1:2004 is not applicable in this instance. Minimum Queuing Provisions The development proposal provides 4m queuing (<1 car) from the property boundary to the first conflict point (visitor space). Given the small scale of the car park and low turnover nature, the chances of a vehicle entering at the same time as a vehicle is manoeuvring in/out of the visitor space is expected to be extremely remote. Site: 36 - 38 Duke Street, Sunshine Beach 14 Reference: 23BRT0004 RP01
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix D - Traffic Engineering Report.pdfRelated documentApplication case desk ↗
About this file
- File size
- 4.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.