Table 4 -Rion NL42 Measurement Summary

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Date Average Acoustic Descriptor, dB(A)
Leg Loo Lio Li

D* E* N* D* E* N* D* E* N* D* E* N*
20/11/19 54 48 44 51 46 37 56 50 | 46 66 56 59
21/11/19 52 49 44 49 46 36 53 50 | 46 66 59 61
22/11/19 52 49 44 49 46 36 53 50 | 45 66 60 61
23/11/19 52 48 44 49 46 35 54 | 49 | 46 66 58 60
24/11/19 53 48 43 49 45 36 56 50 | 45 67 58 61
25/11/19 52 49 43 49 46 37 54 51 45 66 61 61
26/11/19 57 51 44 52 47 37 59 54 46 70 59 60
27/11/19 54 51 56 67
AVERAGE 53 49 44 50 46 36 55 51 46 67 59 60

 

* D- Day (7:00-18:00), E- Evening (18:00 — 22:00), N-Night (22:00-7:00)

4.4.2 Attended Measurement Results

Table 5 -Loading Dock Activity, Attended Measurements

 

 

 

 

 

 

Location’ Noise Source Acoustic Descriptor, dB(A)
Leq Lmax Lpeak
1 Mechanical plant deck @ 25 57 62 78
metres
2 Reversing signal from trolley 69 76 83
collection truck
3 Mechanical plant noise 71 73 85
through exhaust/grille @ 1
metre away

 

 

 

 

 

' Refer to Figure 2 for location on map.

I\obs\2019\20191414\20191414.1\20200115SSA_R2_Existing_Acoustic_Environment.docx

 

 
Log in to download the original file

Attachment 4 - Existing_Acoustic_Environment (22.01.20).pdf · 3.9 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.