Original source · versioned page text
Reference Document Ecological Assessment Report - Urban Catalyst 3 18 July 2025
SITE INFORMATION
115 m
114 m
113 m
112 m
111 m
110 m
109 m
108 m
115 m
107 m
108 m
109 m
110 m
111 m
112 m
113 m
114 m
LOT 2
BAL ZONE
RP/SP RP806872 MEDIUM
INDICATIVE DRIVEWAY
LOCALITY POMONA
COUNTY MARCH
SITE AREA 36.76 HA
LOCAL AUTHORITY NOOSA SHIRE
COUNCIL
SITE COVER
COVERED 1,013 m² 0.28%
UNCOVERED 366,681 m² 99.72%
SITE AREA 367,694 m² 100%
SITE 3: PROPOSED PORCH
NOTES DWELLING PAD 40m x 40m = 51.75 m²
These notes are to be read in conjunction
with sheet: 002 GENERAL NOTES RL: 120 mm
115.3
005 WHS REQUIREMENTS
006 WHS REQUIREMENTS CON. APPROXIMATE LOCATION OF GARAGE
60,000L RAINWATER TANKS = 38.19 m²
Lot subject to bushfire attack assessment.
Refer AS3959-2018 for construction details.
BAL: REFER REPORT
PATIO
Prepared By: BUSHFIRE RISK REDUCERS PROPOSED GARAGE = 39.27 m²
Report No: 015.06.21
Date: 30/06/2021 PROPOSED DWELLING
A flood search has not been carried out.
EFFLUENT ASWTP
Check with Local Authority for minimum REFER HYDRAULIC ENGINEERING
& maximum construction heights.
All measurements are in millimetres unless BAL ZONE BAL ZONE
oted otherwise. Do not scale off drawings, HIGH HIGH
11
5
m
use written dimensions only.
106 m
The boudaries shown have been sourced
from the subject Survey Plan or as noted,
114
and have not been checked. BAL ZONE
m
BUFFER
Distances from features to the shown
boundaries should not be relied upon.
105
113
m
If positional accuracy is critical a boundary
m
identification survey may be required.
The certificate of title has not been searched
112
& should be checked for any encumbrances. m
104 m
The contours may not represent the Local
Authority definition of "ground level"
111
m
The location of services (visible & non-
107 m
visible) are approximate only. Builder to
determine the exact location of services
106 m
on site prior to construction.
103 m
105 m
These plans are to be read in conjunction
110 m
with any structural or civil engineering
drawings; and all other consultants drawings
& details and with any other written
instructions issued. 109 m
EFFLUENT DISPOSAL AREA
102 m
108 m SURFACE IRRIGATION
1 SITE PLAN REFER HYDRAULIC ENGINEERING
101 SCALE 1 : 400 107 m
105 m
106 m
NOT FOR CONSTRUCTION
© COPYRIGHT The design illustrated and these documents remain the exclusive property of VERS DEVELOPMENT PTY LTD as trustee for VAN SLYKE
TRUST trading as DRAFTROOM and may not be reproduced or used in part or in whole without the expressed written permission of DRAFTROOM
Issue Description Date By Project Address Sheet Title Project Number
draftroom.com.au
E
F
CLIENT CHANGES
SHED LOCATIONS
06/02/2024
18/04/2024
ALC
LVS
Lot 2 (#555) Louis Bazzo Drive Site Plan DR23-0301
G OVERLAY AREAS 02/10/2024 LVS POMONA QLD 4568 Sheet
H
I
SITE 2 AMENDMENTS
PROTECTED PLANTS OVERLAY
22/11/2024
28/11/2024
LVS
LVS
QBCC 15380229 | BDQ 2494
PO Box 959 Caloundra QLD 4551 Author Laurence van Slyke
101
J SHED AMENDMENTS 08/07/2025 LVS Client Date Issue
0431 412 485 18/07/2025
K AMENDMENTS 18/07/2025 LVS [email protected] Tim OLAH Scale 1 : 400 @ A3 K