Reference Document Ecological Assessment Report - Urban Catalyst 3 18 July 2025
AREA SCHEDULE
PROPOSED DWELLING 26150
LIVING 197.19 m²
2100 21950 2100
GARAGE 38.19 m²
PORCH 6.19 m² 3400 530 3400 3400 5300 5370
VERANDAH 163.56 m²
TOTAL 405.13 m²
NOTES A
These notes are to be read in conjunction 400
300
with sheet: 002 GENERAL NOTES
005 WHS REQUIREMENTS
006 WHS REQUIREMENTS CON. N
Lot subject to bushfire attack assessment.
Refer AS3959-2018 for construction details.
BAL: REFER REPORT
2100
Prepared By: BUSHFIRE RISK REDUCERS PORCH
Report No: 015.06.21 2.70 x 5.26
Date: 30/06/2021 2x 900 ALD 2x 900 ALD 2x 900 ALD 2x 900 ALD 2x 900 ALD
All measurements are in millimetres unless 920+SL
oted otherwise. Do not scale off drawings,
use written dimensions only.
15/06 ADH
3020
BED 2 BED 3 BED 4 ENSUITE
OBSCURE
24/36 VSD
3170
3170
These plans are to be read in conjunction
ROBE
3.02 x 3.40 3.17 x 3.40 3.17 x 3.40 TILE
with any structural or civil engineering
drawings; and all other consultants drawings ENTRY
820 CSD
& details and with any other written TIMBER
instructions issued. 24/21 VSD 24/21 VSD
870
WM
530
All fixtures & fittings shown are indicative only. DRY BRM 870 870 ROBE ROBE ROBE ROBE
Refer to builders specifications & scope of
21/09 ADH
850 ALD
works for details. WIR
2460
2250
8860
9040
870
L'DRY CARPET
24/15 VSD
Refer to builders specifications & scope of
works for materials & details of finish. Refer MUD CBD LINEN 4SH DRESSER
15640
to window & door manufacturers specifications
UBO+CT+RH
300 W E 301
12/06 ADH
& schedules for details & dimensions.
820 CSD
REF
KITCHEN
WC
OBSCURE
1050
SPACE DINING LIVING
5020
TILE
Protection of openable windows in bedrooms 5.02 x 4.25 5.02 x 4.25
must be provided where the floor below the BED 1
21/21 ADH
870
RS ) G
window is 2m or more above the surface WIP 3.30 x 5.39
3300
BATH
(RA CEILIN
beneath & must comply with NCC Part 3.9.2.6.
820 CSD
TILE
FTE
2110
ED
Smoke alarms to be provided & installed in
RA K
accordance with AS 3786 and NCC Part 3.7.5
& to be powered from the consumer mains;
& be interconnected where there is more than 15/15 ASW AAW15/21 GAS 27/60 AST-6 24/42 ASD-4
one alarm. OBSCURE
STRUT
2100
These plans shall be read in conjunction with
any House Energy Rating (HERS) report & shall
be constructed in accordance with the stamped
plans endorsed by the accredited Thermal PATIO
4500
Performance Assessor without alteration. 4.50 x 8.63
2400
S
1 FLOOR PLAN - GROUND A
301
400
200 SCALE 1 : 100
3400 1650 2610 8490 5390
NOT FOR CONSTRUCTION
© COPYRIGHT The design illustrated and these documents remain the exclusive property of VERS DEVELOPMENT PTY LTD as trustee for VAN SLYKE
TRUST trading as DRAFTROOM and may not be reproduced or used in part or in whole without the expressed written permission of DRAFTROOM
Issue Description Date By Project Address Sheet Title Project Number
draftroom.com.au
E
F
CLIENT CHANGES
SHED LOCATIONS
06/02/2024
18/04/2024
ALC
LVS
Lot 2 (#555) Louis Bazzo Drive Floor Plan - Ground DR23-0301
G OVERLAY AREAS 02/10/2024 LVS POMONA QLD 4568 Sheet
H
I
SITE 2 AMENDMENTS
PROTECTED PLANTS OVERLAY
22/11/2024
28/11/2024
LVS
LVS
QBCC 15380229 | BDQ 2494
PO Box 959 Caloundra QLD 4551 Author Laurence van Slyke
200
J SHED AMENDMENTS 08/07/2025 LVS Client Date Issue
0431 412 485 18/07/2025
K AMENDMENTS 18/07/2025 LVS [email protected] Tim OLAH Scale 1 : 100 @ A3 K