PCA-WI-001
2 C A Work Instruction - Micropiling

 

 

 

 

 

AUT EROUND ENGINEERING Uy Revision No: 4 Issue Date: 5/02/16
All Printed Copies are Uncontrolled Page 5of7
Vil. Double check the target depth taking into account the required bond length
for the hollow bars.
Vill. Advance the 90mm EXx drill bit through to the required depth.
IX. Once the target depth is reached, clear the hole with grout flush and pump
excess grout into containment bins for disposal.
4.1.6 Grouting operation

Grout is to be mixed on site and supplied as required. Grout will bé mixed to provide

a water/cement ratio of 0.45:1.

The Grout Plant Operator is responsible for the following aspects of the grouting

operation;

Mixing grout in accordance with the required mix design

Supplying sufficient grout quantities as requested by the Drill Head Worker
Cleaning and maintaining the grouting equipment

Ordering the correct grade and quantity of cement

Liaising with the PCA Support Team in regard to water usage

Excess grout from the grouting operation is to be pumped by PCA into grout
containment areas onsite and disposed of as required.

The grouting process includes the following steps;

Check the installation records for the drilled depth of the pile to be grouted.
Establish a waste grout container that can be used to store any leftover
grout.

Before pumping the grout to the pile, carry out a Baroid Mud Balance Test on
a grout sample to ensure it has been batched correctly. The target density is
1.89 +/- 0.05.

Clean up the grout plant and store away equipment until required. Ensure
the grout cubes (if required) are stored and labelled appropriately.

 

Used in these records

About this file

File size
26.8 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Operational Works Application OPW17-0561.pdf · 26.8 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.