Water Supply for Fire Fighting Purposes
PO3 AO3.1 AO3.1 is not applicable.
Development provides an adequate water supply for fire fighting Premises are connected to the reticulated water supply.
purpose which is reliable, safely located and freely accessible. Performance Outcome PO5 and Acceptable Outcome
Editor's note—For reconfiguring a lot, water supply needs to AO5 can be met as there is an existing dam onsite water
volume of more than 5,000 litres.
provide for a minimum flow and pressure of 10 litres a second
at 200kPa at all times for fire fighting purposes.
OR
AO3.2
Where there is no available reticulated water supply, the premises
has:
(a) an accessible dam, swimming pool or water tank available
for fire fighting purposes with an onsite water volume of not
less than 5,000 litres; and
(b) a water supply outlet pipe 50 millimetres in diameter fitted
with a standard fire brigade fitting connected to the water
supply (other than where the water supply is in a swimming
pool or dam).