Original source · versioned page text
2019-02-18 General Committee Agenda
The original of this document is very large (13.0 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Text sections have not been matched to the original PDF pages. Use the original document to check page numbers.
GENERAL COMMITTEE MEETING AGENDA 18 FEBRUARY 2019
Earthworks
33. All earthworks must be undertaken in accordance with a development permit for
Operational Works and in compliance with the provisions of AS 3798: Guidelines on
Earthworks for Commercial and Residential Development, with geotechnical testing
undertaken in accordance with Section 8 of the Standard, and to a minimum of ‘Level
2’ supervision Test results as required by AS 3798 and/or the directions of the
supervising engineer. A certification of the earthworks must be provided by a RPEQ
and submitted to Council prior to the final inspection of the completed works by
Council.
34. Earthworks works required on site must be carried out so as not to cause the
additional ponding of water on any adjoining lands or the blockage of, or interference
with, any natural watercourses.
35. Earthworks carried out on site must not affect the structural integrity of any of the
existing fences and/or structures and/or lands that border the development site.
Fences that are affected must be replaced prior to the Building Certifier issuing the
Certificate of Classification. In this regard any fences to be replaced must be clearly
shown on the plans submitted for Operational Works approval.
36. All earthworks and any associated batters must be contained entirely within the
subject site unless written permission from the respective landowner(s) is provided to
Council.
37. Where the development involves changes to the existing levels over, or adjacent to,
drainage, water supply or sewerage infrastructure, all access chamber surface levels
must be adjusted to provide a freeboard of 100mm above the finished ground surface
level or as required by the service provider and/or the approved plans for Operational
Works.
38. All retaining walls and stormwater headwalls must be designed and constructed in
accordance with the planning scheme and must be certified by an RPEQ where
exceeding 1.0m in height. All retaining walls that are publicly accessible and exceed
1.0m in height must be fitted with a commercial grade safety fence.
Erosion and Sediment Control
39. Any person acting on this permit must prevent erosion and sediment export from
leaving the site. Site control measures such as silt fencing, controlled gravel access
to the site and controlled disposal of waste, will be necessary.
In this regard plans prepared by suitably qualified person detailing the methods and
measures of controlling erosion and sediment are required to be submitted to the
Council in conjunction with an application for the Development Permit for Operational
Works.
Water & Sewer Connections
40. An underground connection to reticulated water and sewerage must be provided to
the development site in accordance with the standards and requirements of Northern
SEQ Distributor–Retailer Authority (Unitywater).
41. A Certificate of Completion from the Northern SEQ Distributor–Retailer Authority
(Unitywater) must be submitted to Council that certifies an underground connection to
reticulated water and sewerage has been provided to the development site.
Electricity and Telecommunication Services
42. Underground reticulated electricity and telecommunication services must be provided
to the development site in accordance with an approval for Operational Works and be
in compliance with the standards and requirements of the relevant service provider.
Page 8 of 61
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.