GENERAL COMMITTEE MEETING AGENDA 15 MARCH 2021
Criteria Planning Scheme Proposal Complies?
Community Semi-Attached Community Semi-
Services Services Attached
Setbacks Front: 6 Front: 6 metres Min: 2.1 metres to X X
metres Managers
workshop
Max: > 6
Other: Half the North: 9.78m
Other: Half the building height South: 3m
building height East: 1.89m X X
Roof form 12 degrees 12 degrees and Not detailed on - -
and has has minimum plans
minimum 600mm eaves to
600mm eaves at least 75% of
to at least 75% the perimeter of
of the the building
perimeter of
the building
Carparking 1 covered 1 covered space Double garage
space per per provided
accommodatio accommodation
n unit or unit or dwelling 32 provided X X
dwelling unit; unit; AND
AND
1 designated Not provided X X
1 designated visitor space per 4
visitor space accommodation
per 4 units or dwelling
accommodatio units, or part
n units or thereof; AND
dwelling units, 1 emergency
or part thereof; vehicle space.
AND
1 emergency
vehicle space. Required: Provided:
246 covered 492
Required: 62 visitor 32
246 covered 1 emergency 0
62 visitor
1 emergency
Landscapin Proposed Proposed Approx. 20% = X X
g population population density 22,000m2
density x 40m2 x 40m2
= 32,472m2 = 32,472m2
In terms of built form, the majority of the sites for each dwelling are 13 metres wide by 21
metres in depth whilst approximately 100 of the sites are 14 x 21 metres, representing an
area of approximately 273m2 and 294m2 respectively. It is proposed to construct a 3 bedroom
dwelling on each site with each dwelling type having a maximum width and length as follows:
Type 1: 12.6 x 17.1 metres
Type 2: 13.5 x 17.1 metres
Type 3: 13 x 17.4 metres
The above tables demonstrates the proposal is generally consistent with the built form
parameters associated with a retirement and special needs facility within the Community