Existing Services Code – The Noosa Plan
Performance Criteria and Acceptable Solutions
Setbacks and easements S14.1 The footing of any structure or building RO14 The proposed sewer diversion within the site
O14 is located clear of the zone of influence but no will be contained within a 3.0m wide
Development near a sewer, water main, stormwater closer than 1.5m (measured horizontally) from easement in favour of Unitywater. All
drain, overland flow path or associated structure infrastructure including sewers, water mains proposed new sewer manholes will have a 2m
does not— and stormwater structures; x 3m wide clear area for maintenance
a) adversely affect the function of the service; AND purposes. Additionally, all new sewer
b) place an additional load on the service; and S14.2 No building or structure overhangs the manholes will be accessible from the
c) unduly increase future maintenance costs. zone of influence; frontages along Val Crescent and Goodchap
AND Street. Refer to the Engineering Services
S14.3 Finished surface levels maintain a Assessment provided by Morgan Consulting
minimum of 600mm of cover, but no Engineers for further details.
greater than 3m of cover to the
underground infrastructure; All buildings and structures will be located
AND outside of the zone of influence and building
S14.4 If the existing surface level is altered, piers and footings will be extended below the
surface level services including manholes and zone of influence for all existing and proposed
inspection points are altered to match the new underground services.
surface level;
AND
S14.5 Alterations are constructed in accordance
withPSP6 –Engineering Design Standards —
Water and Sewerage and Section 4 of PSP5 –
Engineering Design Standards – Roads,
Drainage and Earthworks;
OR
S14.6 Existing services are relocated and the
design and construction of the relocated services
is in accordance with PSP6 – Engineering Design
Standards — W ater and Sewerage and Section 4
of PSP5 – Engineering Design Standards –
Roads, Drainage and Earthworks.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Engineering Services Assessment.pdfRelated documentApplication case desk ↗
About this file
- File size
- 10.3 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.