 Performance Outcomes                 Acceptable Outcomes                          Response

                                              alternatives for otherwise
                                              impervious areas
                                              wherever possible;
                                           c) provide for capture and
                                              reuse of stormwater for
                                              non-potable purposes for
                                              gardening, toilet flushing,
                                              laundry and hot water
                                              supply uses;
                                           d) incorporate appropriate
                                              detention features; and
                                           e) incorporate natural
                                              channel design principles

                                     Editor’s note: The Sustainable Building
                                     Design Code includes requirements for
                                     stormwater capture and reuse.


 PO11                                 AO11.1                                       Not Applicable

 Water sensitive urban design         The design and construction of a             Development does not involve
 principles are applied to achieve    natural channel or natural                   channel construction.
 multifunctional design of            channel rehabilitation works are
 waterways, wetlands and              in accordance with the Natural
 drainage lines that provide for:     Channel Design Guidelines
                                      (Brisbane City Council) having
    a) stormwater conveyance
                                      regard to local topography,
       that uses natural channel
                                      geology and geomorphology.
       design;
    b) protection of landscape        AO11.2                                       AO11.2 Complies
       features and ecological
       important areas including      Landscape features, plant                    Refer to Appendix G for further
       terrestrial and aquatic        species and habitat types used in            detail.
       habitat                        stormwater conveyance channels
    c) aesthetic and passive          are complementary to the local
       recreation values;             context and natural waterways.
    d) flood management and
                                      AO11.3                                       Not Applicable
       conveyance of external
       catchment stormwater           Bank and bed stability and                   Development is not located along
       through the development;       planting densities result in a               any waterbody or channel banks.
    e) landscaping that               stable channel over the long term
       incorporates local native      and minimal potential for pest
       species; and                   plant species.
    f) bed and bank stability.
                                      AO11.4                                       AO11.4 Complies

                                      Water Sensitive Design                       Refer to Appendix F & G for
                                      measures are incorporated into               further detail.
                                      the development, as detailed in
                                      the document Water Sensitive
                                      Designs small improvements,


                                                                                                                         URBIS
120PLANNING SCHEME CODE ASSESSMENT                                             FINAL TOWN PLANNING REPORT - 47 GOODCHAP STREET

Log in to download the original (Appendix L - Code Assessment.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.