Original source · versioned page text
App A - Acoustic Report - Minor Change - 12.08.2025
Sunshine Beach Surf Life Saving Club #1966d1-B Acoustic Report (Minor Change Application) 12 August 2025 2 Regulatory Requirements 2.1 Summary of Existing Approval Conditions Noosa Council issued a Decision Notice – Minor Change on 18 December 2024 (reference: MCU17/0024.02). The Decision Notice includes existing approval conditions which relate to amplified noise at the premises. These conditions are reproduced below: NOISE 8. All amplified noise at the premises must be conducted through a sound limiting device at all times to ensure that noise does not exceed the following: i. between 6a.m. and 10p.m.—the adjusted maximum sound pressure level LA10, plus adjustments for tonal and impulse components, exceeding the background level LA90 by more than 10dB(A); ii. between 10p.m. and 6a.m.—the sound pressure level LOCT10, in a full octave band with centre frequencies from 63HZ to 2000HZ, exceeding the background level LOCT90 by more than 8dB in any octave band. Condition 8 i and ii shall apply for 12 months commencing 22 May 2020, unless further extended by Council in writing. After that time if not extended by Council in writing condition 8 iii and iv shall apply: iii. Noise emanating from the premises including amplified or non-amplified noise and patron noise prior to 10.00pm must not exceed 90dBC, fast response, when measured approximately 3 metres from the source of the noise; and iv. Noise emanating from the premises including amplified or non-amplified noise and patron noise after 10.00pm must not exceed 85dBC, fast response, when measured approximately 3 metres from the source of the noise. 9. The sound limiting device is to have a locking mechanism, which is to be locked at all times except for inspection or maintenance work on the device. 10. Access to the sound limiting device, except for maintenance work, is restricted to the licensee, nominee and the person in charge of the premises at the time. 11. The sound limiting device must be checked and if necessary calibrated by a qualified acoustic engineer at least every 12 months to ensure compliance with the conditions of the license. Evidence of the sound limiting device calibration must be made available to an investigator or police on request. Live It Acoustics Page 3
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original (App A - Acoustic Report - Minor Change - 12.08.2025.pdf)
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.